Vapor Pressure Formulations: Antoine Equation & Clausius-Clapeyron
Covers pure component vapor pressure formulations, deriving the Clausius-Clapeyron equation from fundamental thermodynamics, Antoine parameters, and liquid boiling point estimation.
1. Theoretical Foundations & Engineering Mechanics
Phase Equilibrium & Clapeyron Equation
Along the liquid-vapor co-existence curve, the chemical potential (Gibbs free energy) of the liquid and vapor phases are identical: $dG_L = dG_V$. From the fundamental property relation $dG = -S dT + V dP$:
$$\frac{dP_{sat}}{dT} = \frac{\Delta S_{vap}}{\Delta V_{vap}} = \frac{\Delta H_{vap}}{T \Delta V_{vap}}$$
Where $\Delta H_{vap}$ is the latent heat of vaporization, and $\Delta V_{vap} = V_V - V_L$ is the volume change upon vaporization.
The Clausius-Clapeyron Equation
Introducing two practical engineering approximations:
1. Liquid molar volume is negligible compared to vapor volume ($V_V \gg V_L \implies \Delta V_{vap} \approx V_V$).
2. The vapor obeys the ideal gas law ($V_V = R T / P_{sat}$).
Substituting into the Clapeyron relation:
$$\frac{dP_{sat}}{dT} = \frac{\Delta H_{vap} P_{sat}}{R T^2} \implies \frac{d \ln P_{sat}}{dT} = \frac{\Delta H_{vap}}{R T^2}$$
Integrating assuming constant $\Delta H_{vap}$ yields the classical Clausius-Clapeyron equation:
$$\ln\left(\frac{P_{sat,2}}{P_{sat,1}}\right) = -\frac{\Delta H_{vap}}{R} \left( \frac{1}{T_2} - \frac{1}{T_1} \right)$$
The Antoine Semi-Empirical Formulation
To capture the mild temperature dependence of $\Delta H_{vap}$ over extended spans, chemical engineers utilize the Antoine Equation:
$$\log_{10}(P_{sat}) = A - \frac{B}{T + C} \quad \text{or} \quad \ln(P_{sat}) = A - \frac{B}{T + C}$$
Where $A, B, C$ are component-specific regression constants. When $C = 0$, Antoine reverts to the Clausius-Clapeyron linear form.
2. Governing Equations & Mathematical Formulation
$$\frac{d \ln P_{sat}}{dT} = \frac{\Delta H_{vap}}{R T^2}$$
$$\ln\left(\frac{P_2}{P_1}\right) = -\frac{\Delta H_{vap}}{R}\left(\frac{1}{T_2} - \frac{1}{T_1}\right)$$
$$\log_{10}(P_{sat}\text{ [bar]}) = A - \frac{B}{T\text{ [K]} + C}$$
$$T_b = \frac{B}{A - \log_{10}(P)} - C$$
• Molar volume of liquid is negligible compared to vapor molar volume.
• Vapor phase behaves as an ideal gas.
• Enthalpy of vaporization $\Delta H_{vap}$ is approximately constant across the integration interval.
• Antoine parameters are valid only within their tabulated temperature window.
• Mixing up $\log_{10}$ and natural $\ln$ forms of the Antoine equation, resulting in orders-of-magnitude pressure errors.
• Using temperature in Kelvin when the Antoine parameter table expects Celsius.
• Extrapolating Antoine coefficients beyond their upper valid temperature limit into the near-critical region.
• Forgetting that Clausius-Clapeyron breaks down near the critical point where $V_L \to V_V$.
3. Applied Engineering Worked Example
Pure n-hexane has a normal boiling point of $T_{b1} = 68.74^\circ\text{C}$ ($341.89\text{ K}$) at standard atmospheric pressure $P_1 = 1.01325\text{ bar}$. Its latent heat of vaporization is $\Delta H_{vap} = 28.85\text{ kJ/mol}$.
- Using the Clausius-Clapeyron equation, estimate the vapor pressure of n-hexane at $T_2 = 25.0^\circ\text{C}$ ($298.15\text{ K}$) in bar.
- The Antoine coefficients for n-hexane (with $P$ in bar, $T$ in K) are:
$$A = 4.00266, \quad B = 1171.530, \quad C = -48.784$$
Calculate the vapor pressure using the Antoine equation at $25.0^\circ\text{C}$. - Compare the Clausius-Clapeyron estimate to the Antoine value and determine the percent deviation.
- Calculate the boiling temperature of n-hexane atop a mountain where barometric pressure is $0.750\text{ bar}$.
Step-by-Step Analytical Solution:
-
Clausius-Clapeyron calculation:
$$R = 8.31446 \times 10^{-3}\text{ kJ/(mol}\cdot\text{K)}$$
$$\frac{\Delta H_{vap}}{R} = \frac{28.85}{8.31446 \times 10^{-3}} = 3469.86\text{ K}$$
$$\frac{1}{T_2} - \frac{1}{T_1} = \frac{1}{298.15} - \frac{1}{341.89} = 0.0033540 - 0.0029249 = +0.0004291\text{ K}^{-1}$$
$$\ln\left(\frac{P_2}{1.01325}\right) = -(3469.86)(0.0004291) = -1.4889$$
$$P_2 = 1.01325 \times e^{-1.4889} = 1.01325 \times 0.22562 = \mathbf{0.2286\text{ bar}}$$ -
Antoine equation calculation:
$$\log_{10}(P_{sat}) = 4.00266 - \frac{1171.530}{298.15 - 48.784} = 4.00266 - \frac{1171.530}{249.366} = 4.00266 - 4.69803 = -0.69537$$
$$P_{sat} = 10^{-0.69537} = \mathbf{0.2017\text{ bar}}$$ -
Percent deviation:
$$\text{Error} = \frac{0.2286 - 0.2017}{0.2017} \times 100\% = \mathbf{+13.3\%}$$
Clausius-Clapeyron overpredicts because $\Delta H_{vap}$ increases at lower temperatures. -
Boiling point at $0.750\text{ bar}$ via Antoine:
$$\log_{10}(0.750) = -0.12494$$
$$-0.12494 = 4.00266 - \frac{1171.530}{T + C}$$
$$\frac{1171.530}{T - 48.784} = 4.00266 - (-0.12494) = 4.12760$$
$$T - 48.784 = \frac{1171.530}{4.12760} = 283.828 \implies T = 283.828 + 48.784 = 332.61\text{ K} = \mathbf{59.46^\circ\text{C}}$$
Interactive Practice Drill: Vapor Pressure Formulations: Antoine Equation & Clausius-Clapeyron
Completed this lesson?
Record your study progress, build your daily streak, and unlock +25 XP toward your next engineering tier.
Connected ChemProCal Tool