Cryogenic Mercury Removal Unit (MRU) Design Theory

Mercury guard beds are non-regenerative chemisorption vessels installed upstream of cryogenic liquefaction units to prevent catastrophic failure of aluminum cold boxes.

1. Chemisorption Kinetics & Sorbent Mass Sizing

Sorbent mass is sized by integrating annual mercury influx over the design service life (typically 3 to 5 years):

$$M_{\text{sorbent}} = \frac{Q_{\text{std}} \cdot t_{\text{life}} \cdot (C_{\text{in}} - C_{\text{out}})}{L_{\text{cap}}} \cdot (1 + \text{MTZ}_{\text{margin}})$$

2. Ergun Pressure Drop Equation

Gas pressure drop through the packed sorbent bed is computed via the classical Ergun correlation combining laminar viscous drag and turbulent kinetic losses:

$$\frac{\Delta P}{H} = 150 \frac{(1-\epsilon)^2}{\epsilon^3} \frac{\mu v_s}{d_p^2} + 1.75 \frac{1-\epsilon}{\epsilon^3} \frac{\rho_g v_s^2}{d_p}$$