ChemProCal
Knowledge Base + New Calculation Login Sign Up
Natural Gas Thermodynamics Worked Example Choke Sizing Joule-Thomson API 6A Blowdown MDMT

Worked Example: Wellhead Bean Choke Sizing, Critical Sonic Flow, and Joule-Thomson Depressurization

Calculate critical pressure ratio, sonic mass flow, and isenthalpic Joule-Thomson refrigeration drop for a 24/64 inch bean choke discharging from 240 barg to 65 barg to verify MDMT metallurgy.

Published
October 17, 2026
Reading Time
~7 Minutes
Technical Review
Process Design Engineer (B.Tech Chemical Engineering, 5+ Yrs Experience)
📑 Table of Contents (Tap to view sections)

    A high-pressure natural gas wellhead choke is the primary barrier controlling production deliverability and protecting downstream separation facilities from overpressure. When high-pressure gas expands across a fixed choke bean or emergency depressuring blowdown valve, two critical physical phenomena govern system integrity:

    1. Sonic Choking: As downstream pressure drops below the critical pressure ratio ($P_2 / P_1 < r_c$), gas velocity at the choke throat reaches the local speed of sound ($\text{Mach } 1.0$). Beyond this threshold, flow is choked—mass flow is strictly determined by upstream pressure and temperature, completely independent of downstream fluctuations.
    2. Joule-Thomson (JT) Refrigeration: High-pressure gas experiences a severe isenthalpic temperature drop across the restriction. If downstream temperatures plunge below the Minimum Design Metal Temperature (MDMT), carbon steel piping undergoes brittle fracture, risking cataclysmic containment loss.

    This worked example models an API Spec 6A #24 bean choke operating across a severe $175\text{ bar}$ differential.


    1. Wellhead Operating & Geometry Data

    A high-pressure offshore gas well produces through an API Spec 6A fixed bean choke into a production header: * Upstream Wellhead Pressure ($P_1$): $240.0\text{ barg}$ ($241.01\text{ bar(a)} = 3,495.6\text{ psia}$) * Upstream Wellhead Temperature ($T_1$): $50.0^\circ\text{C}$ ($122.0^\circ\text{F} = 323.15\text{ K}$) * Downstream Header Pressure ($P_2$): $65.0\text{ barg}$ ($66.01\text{ bar(a)} = 957.4\text{ psia}$) * Choke Bean Size: $24/64\text{ inch}$ ($d_o = 0.375\text{ in} = 9.525\text{ mm}$) * Orifice Discharge Coefficient ($C_d$): $0.85$ (calibrated for API fixed bean) * Gas Properties: Specific Gravity $G = 0.65$ ($M_{mix} = 18.83\text{ kg/kmol}$) * Isentropic Expansion Ratio ($k = c_p/c_v$): $1.30$ * Upstream Compressibility ($Z_1$): $0.85$


    2. Step 1: Critical Pressure Ratio & Sonic Flow Verification

    The theoretical critical pressure ratio ($r_c$) at which throat velocity reaches Mach 1 is:

    For $k = 1.30$:

    Critical Choking Pressure ($P_{crit}$):

    Actual Pressure Ratio ($r_{act}$):

    Flow Regime Determination:

    Since $r_{act} = 0.2739 < r_c = 0.5457$: * The gas is in CRITICAL (SONIC / CHOKED) FLOW. * Acoustic waves cannot propagate upstream against supersonic gas expansion. Any pressure disturbance downstream of the choke will have zero effect on wellhead flow rate.

    graph LR
        A[Upstream P1 = 240 barg] --> B[Bean Choke Throat: Mach 1.0, Pcrit = 131.5 barg]
        B --> C[Isenthalpic Expansion]
        C --> D[Downstream P2 = 65 barg, T2 = -11.3°C]
    

    3. Step 2: Choke Throat Area & Sonic Mass Flow Rate

    A. Bean Orifice Cross-Sectional Area ($A_o$):

    B. Sonic Mass Flow Rate via API 520 / ISO 5167 Formulation:

    Under critical choked flow, the mass flux is:

    Evaluating component terms: 1. $P_1 = 24,101,000\text{ Pa}$ 2. $Z_1 \cdot R \cdot T_1 = 0.85 \times 8,314.46 \times 323.15 = 2,283,780\text{ J/kmol}$ 3. $\frac{k \cdot M_{mix}}{Z_1 R T_1} = \frac{1.30 \times 18.826}{2,283,780} = 1.0716 \times 10^{-5}\text{ kg}^2/\text{J}$ 4. $\left( \frac{2}{k+1} \right)^{\frac{k+1}{k-1}} = (0.86957)^{\frac{2.30}{0.30}} = (0.86957)^{7.6667} = 0.3424$ 5. Square root term $= \sqrt{1.0716 \times 10^{-5} \times 0.3424} = \sqrt{3.669 \times 10^{-6}} = 0.0019155$

    Substituting into the mass rate formula:

    Converting to hourly and imperial mass rates:


    4. Step 3: Volumetric Gas Flow Rate at Standard Conditions

    Using standard gas density $\rho_{std} = 0.7980\text{ kg/Sm}^3$:

    Converting to MMSCFD:


    5. Step 4: Joule-Thomson Depressurization Cooling ($\Delta T_{JT}$)

    During rapid expansion across a restriction with zero shaft work and negligible external heat transfer, the expansion is isenthalpic ($\Delta H = 0$).

    The Joule-Thomson cooling coefficient ($\mu_{JT}$) is:

    For lean natural gas ($G = 0.65$) expanding across $240\text{ barg} \to 65\text{ barg}$:

    Total Differential Pressure ($\Delta P$):

    Temperature Drop:

    Downstream Gas Temperature ($T_2$):


    6. Step 5: Low-Temperature Metallurgy & MDMT Assessment

    Under ASME Section VIII Div. 1 (UCS-66) and ASME B31.3 (Process Piping), all pressure-containing materials must be rated for the Minimum Design Metal Temperature (MDMT) to prevent catastrophic brittle fracture.

    graph TD
        A[Normal Upstream: +50°C] --> B[Choke Depressurization: dT = 61.3°C]
        B --> C[Downstream Temperature: -11.3°C]
        C --> D[Standard Carbon Steel A106 Gr B MDMT = -29°C]
        D --> E[Acceptable for Normal Production Choking]
        B --> F[Emergency Full Depressurization to Flare at 1 barg]
        F --> G[Downstream T drops to -45°C!]
        G --> H[MANDATES LTCS ASTM A333 Gr 6 or 316L SS]
    

    Material Selection Verdict:

    1. Steady-State Production Choking ($P_2 = 65\text{ barg}$):
    2. Operating temperature is $-11.25^\circ\text{C}$.
    3. Standard Normalized Carbon Steel (ASTM A106 Gr B / A350 LF2) has a rated MDMT of $-29.0^\circ\text{C}$.
    4. Status: ACCEPTABLE without impact testing.
    5. Emergency Blowdown / Full Depressurization ($P_2 \to 1.5\text{ barg}$):
    6. If the choke discharges during a platform ESD emergency blowdown to flare ($\Delta P \approx 238\text{ bar}$):
    7. At $-33.3^\circ\text{C}$, standard carbon steel falls below its Charpy V-notch ductile-to-brittle transition temperature.
    8. Requirement: Downstream piping must be specified in Low-Temperature Carbon Steel (LTCS - ASTM A333 Grade 6) with mandatory Charpy impact testing at $-46^\circ\text{C}$.

    7. Performance Curve across Standard Bean Sizes

    The table below illustrates flow capacity and JT refrigeration across API Spec 6A bean sizes at $240\text{ barg}$ upstream:

    Bean Size (64ths in) Orifice ID (in) Orifice ID (mm) Choked Flow (MMSCFD) Mass Flow (kg/h) Downstream Temp $T_2$ ($^\circ\text{C}$) Acoustic Power / AIV Risk
    $16/64\text{ in}$ $0.250$ $6.35$ $10.81$ $10,175$ $-11.25$ Low
    $20/64\text{ in}$ $0.312$ $7.94$ $16.88$ $15,899$ $-11.25$ Low
    $24/64\text{ in}$ (Base) $0.375$ $9.525$ $24.31$ $22,895$ $-11.25$ Moderate
    $28/64\text{ in}$ $0.438$ $11.11$ $33.09$ $31,162$ $-11.25$ High
    $32/64\text{ in}$ $0.500$ $12.70$ $43.22$ $40,702$ $-11.25$ ⚠️ Severe AIV

    Takeaways:

    • Mass flow scales strictly with the square of the bean diameter ($d_o^2$). Doubling the bean size from $16/64$ to $32/64$ quadruples capacity from $10.81$ to $43.22\text{ MMSCFD}$.
    • Temperature drop is determined by fluid thermodynamics and pressure drop ($\Delta P$), remaining constant across bean diameters, but high mass rates dramatically increase Acoustic-Induced Vibration (AIV) risks on downstream pipe tees and reducers.
    
    Apply This Fundamental

    Gas Choke & Pressure Relief / Depressurization Analyzer

    Apply this methodology directly in the ChemProCal calculator.

    Open Calculator →

    References

    • API Spec 6A - Specification for Wellhead and Tree Equipment (21st Edition, American Petroleum Institute, 2018) - Standard [Link ↗]
    • API RP 520 Part I - Sizing, Selection, and Installation of Pressure-relieving Devices (10th Edition, 2020) - Standard [Link ↗]
    • ASME Boiler and Pressure Vessel Code, Section VIII, Division 1: Rules for Construction of Pressure Vessels (2021 Edition) - Standard [Link ↗]
    ⚡ Interactive Estimator

    Live Control Valve Sizing (Cv/Kv) & Aerodynamic Noise Estimator

    Adjust parameters below to test the methodology equations in real time before running full simulations:

    Required Valve Flow Coefficient ($C_v$) 28.9 US gpm·psi⁻⁰·⁵
    Metric Flow Coefficient ($K_v$) 25.0 m³/h·bar⁻⁰·⁵
    Choked Flow Critical $\Delta P_{choked}$ 7.78 bar
    Flow Regime / Choking Status Sub-Critical (Non-Choked)
    Cavitation Index ($\sigma_c$) or Expansion ($Y$) σ = 2.49 (Incipient Safe)
    Estimated Sound Pressure Level (IEC 60534-8-3) 74.5 dBA @ 1m (Quiet)
    ✓ Linear sub-critical flow regime. Aerodynamic / hydrodynamic acoustic noise complies with OSHA continuous limits (< 85 dBA).

    Engineering Standards & Peer-Review Governance

    Authored & Verified by Process Design Engineer (B.Tech Chemical Engineering, 5+ Yrs Experience)

    Critical pressure ratios and sonic mass flux are evaluated per API Spec 6A and API 520 Part I orifice flow equations. Isenthalpic Joule-Thomson refrigeration drops and MDMT metallurgy compliance conform to ASME Section VIII Div. 1 UCS-66.

    Domain Thermodynamics
    Governing Standards API Spec 6A, API RP 14B, API 520 Part I, ASME Section VIII Div 1
    Content Classification Worked Example
    Verification ✓ Benchmark Validated
    Cite this technical guide:
    ChemProCal Engineering (2026). "Worked Example: Wellhead Bean Choke Sizing, Critical Sonic Flow, and Joule-Thomson Depressurization." ChemProCal Engineering Fundamentals. https://www.chemprocal.com/blog/worked-example-gas-choke-blowdown-joule-thomson-analysis/