1. Calculation Scope & Governing Equations
This calculator determines hydraulic resistance coefficients ($K$-factors) and equivalent lengths ($L/D$) for standard piping fittings per Crane Technical Paper 410 and the Hooper 2K / Darby 3K methods.
2. Standard K-Factors for Common Fittings (Crane TP 410)
| Fitting Type | Turbulent Equivalent Length ($L_e/D$) | Nominal K-Factor (4-inch Pipe) |
|---|---|---|
| 90° Standard Elbow (R/D = 1.0) | 30 | 0.50 – 0.55 |
| 90° Long Radius Elbow (R/D = 1.5) | 20 | 0.30 – 0.35 |
| 45° Standard Elbow | 16 | 0.25 – 0.28 |
| Tee (Flow through Run) | 20 | 0.30 – 0.35 |
| Tee (Flow through Branch) | 60 | 0.90 – 1.10 |
| Swing Check Valve (Fully Open) | 100 | 1.50 – 2.00 |
3. Engineering Assumptions & Boundary Limits
- Laminar Flow Correction: For Reynolds numbers < 2,000, standard equivalent length methods underpredict loss. The Hooper 2K correlation must be used to account for viscous dissipation.
- Consecutive Fittings: Two closely coupled 90° elbows in different planes generate severe secondary swirling flow, increasing total loss by 20%–40% over individual components.