Executive Summary & Engineering Relevance
Shell-and-tube heat exchangers (STHE) are the workhorses of chemical process thermal integration, accounting for over $65\%$ of all thermal transfer equipment installed across petrochemical plants, petroleum refineries, and power generation stations.
Thermal design of an industrial exchanger involves two coupled disciplines: 1. Thermodynamic Rating: Establishing the effective temperature driving force (Logarithmic Mean Temperature Difference, LMTD) and determining the Multipass Correction Factor ($F$) to account for non-ideal co-current/counter-current flow passes within standard TEMA configurations. 2. Shell-Side Hydrodynamics: Predicting heat transfer coefficients and pressure drops across the tube bundle using the rigorous Bell-Delaware Method (Tinker/Delaware model), which replaces simplistic Kern equations by quantifying the five internal leakage, bypass, and crossflow streams.
A critical design pitfall in process revamps is operating with an $F$-factor below $0.80$ or failing to anticipate a temperature cross—where the cold stream outlet temperature exceeds the hot stream outlet temperature ($T_{c,out} > T_{h,out}$). In a 1-2 multipass exchanger, this causes severe thermal inefficiency, requiring multiple shell passes in series or pure counter-current configurations.
This engineering guide provides the mathematical formulations for counter-current LMTD, analytical $F$-factor derivation for 1-2 and 2-4 TEMA exchangers, the five Bell-Delaware flow streams, shell-side pressure drop evaluation, and a step-by-step worked industrial example for a kerosene-to-crude preheat exchanger.
1. Thermodynamic Driving Force: Counter-Current LMTD
For steady-state heat exchange without phase change where overall heat transfer coefficient ($U$) and fluid heat capacities ($C_p$) are constant along the exchanger length, the rate equation is:
Temperature Profiles in Pure Counter-Current Flow:
Temperature T [°C]
Th,in +-------------------------\
| \ Hot Stream (Th,in -> Th,out)
| \
| + Th,out
|
Tc,out+ + Tc,in
\ /
\ / Cold Stream (Tc,in -> Tc,out)
\----------------------/
Position: x = 0 (Left End) Position: x = L (Right End)
Delta T1 = Th,in - Tc,out Delta T2 = Th,out - Tc,in
1.1 Pure Counter-Current Logarithmic Mean ($\Delta T_{lm}$)
Where: * $\Delta T_1 = T_{h,in} - T_{c,out}$: Temperature approach at the hot end ($K$ or $^\circ C$). * $\Delta T_2 = T_{h,out} - T_{c,in}$: Temperature approach at the cold end ($K$ or $^\circ C$). * (Special Case: If $\Delta T_1 = \Delta T_2$, then $\Delta T_{lm} = \Delta T_1 = \Delta T_2$).
2. Multipass Correction Factor ($F$) & Temperature Cross
In most industrial exchangers (e.g., TEMA E shells with 2, 4, or 6 tube passes), fluid in the tubes flows co-currently with the shell fluid during half the passes and counter-currently during the other half. The true mean temperature difference is smaller than pure counter-current LMTD:
2.1 Thermal Dimensionless Parameters ($P$ and $R$)
The correction factor is parameterized by two dimensionless numbers:
-
Thermal Effectiveness / Temperature Efficiency ($P$): Measures the heating of the cold stream relative to the maximum theoretical temperature difference.
-
Heat Capacity Rate Ratio ($R$): Ratio of cold fluid capacity rate to hot fluid capacity rate.
TEMA 1-2 Exchanger Multipass Configuration:
+-------------------------------------------+
Hot Shell In ->| ===== Shell Flow (Crosses Baffles) ======>| -> Hot Shell Out
| +-------------------------------------+ |
| | === Tube Pass 1 (Co-current) ===> | |
Cold Tube In ->|==| |==| (Floating Head / U-Tube)
| | <=== Tube Pass 2 (Counter-current)==| |
Cold Tube Out<-|==+-------------------------------------+ |
+-------------------------------------------+
2.2 Analytical Formula for 1 Shell Pass, 2 or more Tube Passes (1-2 TEMA E)
2.3 The $F \ge 0.80$ Rule & Temperature Cross
- When a temperature cross occurs ($T_{c,out} > T_{h,out}$), the denominator argument inside the logarithm approaches zero, driving $F$ toward zero vertically.
- TEMA Best Practice: Never design a heat exchanger with $F < 0.80$. Below $0.80$, the slope $dF/dP$ is extremely steep; any small operational fluctuation in flow or fouling will cause the exchanger to suffer an immediate loss of heat duty.
- Solution for $F < 0.80$: Split the duty into two shell passes in series (2-4 exchanger, TEMA F) or multiple TEMA E shells in series.
3. Shell-Side Hydraulics: The Bell-Delaware Method
Simplistic sizing methods (like Donald Q. Kern's 1950 correlation) assume that 100% of the shell fluid traverses the tube bundle in pure crossflow. In reality, manufacturing tolerances between tubes, baffles, and shell produce internal bypassing and leakage.
The Bell-Delaware Method (Delaware Project, 1963) divides the shell-side flow into five distinct streams:
Bell-Delaware Five Shell-Side Flow Streams:
+-----------------------------------------------------------------------------+
| Stream B (Main Crossflow Stream): |
| - The ONLY effective heat transfer stream (typically 40% - 65% of total). |
| - Traverses the tube bundle in crossflow across each baffle bay. |
+-----------------------------------------------------------------------------+
| Stream A (Tube-to-Baffle Hole Leakage): |
| - Leaks through annular gaps between tube OD and drilled baffle holes. |
| - Reduces pressure drop, but moderately effective for heat transfer. |
+-----------------------------------------------------------------------------+
| Stream E (Baffle-to-Shell Diametral Leakage): |
| - Bypasses through the clearance between baffle outer edge and shell ID. |
| - HIGHLY INEFFECTIVE: Forms a stagnant thermal boundary near shell wall. |
+-----------------------------------------------------------------------------+
| Stream C (Bundle Bypass Stream): |
| - Flows around the outer tube limit (OTL) clearance to shell. |
| - Controlled by adding sealing strips and dummy tie-rods. |
+-----------------------------------------------------------------------------+
| Stream F (Pass-Partition Lane Bypass): |
| - Flows through tube pass partition lanes in multipass tube layouts. |
+-----------------------------------------------------------------------------+
Bell-Delaware Correction Factors
The true shell-side heat transfer coefficient ($h_s$) is calculated by derating an idealized crossflow bank coefficient ($h_{ideal}$):
Where: * $J_c$: Baffle cut and window correction factor (typically $0.85 - 1.15$). * $J_l$: Baffle leakage correction for Streams A and E (typically $0.65 - 0.85$). * $J_b$: Bundle bypass correction for Stream C ($0.70 - 0.95$, improved by sealing strips). * $J_s$: Unequal baffle spacing correction at inlet/outlet nozzles ($0.85 - 1.0$). * $J_r$: Laminar flow adverse temperature gradient correction.
Ideal Shell-Side Crossflow Area ($S_m$)
The minimum flow area between tubes at the shell centerline:
Where: * $B$: Central baffle spacing ($m$, typically $0.3 - 0.5 D_s$). * $D_s$: Shell inside diameter ($m$). * $D_{otl}$: Outer tube limit diameter ($m$). * $d_o$: Tube outside diameter ($m$). * $p_t$: Tube pitch ($m$, standard triangular $30^\circ$ or square $90^\circ$, pitch ratio $p_t / d_o \ge 1.25$).
4. Shell-Side Pressure Drop Formulation
Total shell-side pressure drop ($\Delta P_s$) combines crossflow zone losses, window zone losses, and end baffle spaces:
Where: * $N_b$: Number of baffles ($N_b = L / B - 1$). * $\Delta P_{bi}$: Ideal crossflow pressure drop between baffle tips. * $\Delta P_w$: Ideal window pressure drop. * $R_l, R_b, R_s$: Bell-Delaware pressure drop correction factors for leakage, bypass, and nozzle spacing.
5. Comprehensive Step-by-Step Industrial Worked Example
Design Problem Statement:
An oil refinery crude distillation unit (CDU) uses hot kerosene product to preheat cold desalted crude oil: * Thermal Duty: $Q = 2,400\text{ kW}$ ($2.40 \times 10^6\text{ W}$). * Hot Stream (Kerosene, Shell Side): * Inlet Temp: $T_{h,in} = 175.0^\circ\text{C}$ * Outlet Temp: $T_{h,out} = 95.0^\circ\text{C}$ * Cold Stream (Crude Oil, Tube Side): * Inlet Temp: $T_{c,in} = 40.0^\circ\text{C}$ * Outlet Temp: $T_{c,out} = 85.0^\circ\text{C}$ * Exchanger Configuration: TEMA E Shell with 1 Shell Pass and 2 Tube Passes (1-2 STHE). * Assumed Overall Heat Transfer Coefficient: $U = 380\text{ W/m}^2\cdot\text{K}$ ($66.9\text{ Btu/h}\cdot\text{ft}^2\cdot^\circ\text{F}$). * Mechanical Geometry: Shell ID $D_s = 650\text{ mm}$ ($0.65\text{ m}$), Baffle Spacing $B = 300\text{ mm}$, $25\%$ segmental baffle cut.
Calculate: 1. Counter-current LMTD ($\Delta T_{lm}$). 2. Dimensionless parameters $P$ and $R$. 3. Multipass correction factor ($F$) and verify against the $0.80$ TEMA threshold. 4. Effective temperature difference ($\Delta T_{eff}$). 5. Required total heat transfer surface area ($A_{req}$). 6. Shell-side crossflow area ($S_m$).
Step 1: Counter-Current LMTD ($\Delta T_{lm}$)
Temperature approaches:
Logarithmic mean:
Step 2: Dimensionless Parameters ($P$ and $R$)
Check product $P \cdot R$:
Step 3: Multipass Correction Factor ($F$)
Radical term:
Numerator argument:
Numerator value:
Denominator argument:
Calculating $F$:
Assessment against TEMA Standards: The 1-2 configuration is highly thermally efficient and stable. A single TEMA E shell pass is fully validated.
Step 4: Effective Temperature Difference & Required Area
Required heat transfer area:
Step 5: Shell-Side Crossflow Area ($S_m$)
With $D_s = 0.65\text{ m}$, $B = 0.30\text{ m}$, and standard clearances:
If kerosene mass flow rate is $22.5\text{ kg/s}$ (density $\rho = 780\text{ kg/m}^3$):
Hydraulic Check: A crossflow velocity of $0.67\text{ m/s}$ is well within the recommended non-erosive, non-vibrating liquid window of $0.5 - 1.2\text{ m/s}$, ensuring low shell-side pressure drop ($< 0.4\text{ bar}$) and preventing tube acoustic resonance.
6. Common Design Traps & Best Practice Checklist
- Beware of Low $F$-Factor ($F < 0.80$): If $F < 0.80$, never attempt to compensate by simply adding more tube surface area. The exchanger will suffer operational instability during plant turn-down. Reconfigure to two shells in series ($N_s = 2$).
- Optimize Baffle Cut (20% to 30%): Baffle cuts smaller than $15\%$ cause extreme window pressure drops and stagnant zones; cuts larger than $35\%$ cause longitudinal flow rather than crossflow, destroying heat transfer efficiency.
- Control Stream C with Sealing Strips: For tube bundles with large bypass lanes (e.g., pull-through floating heads TEMA T), always install sealing strips every 5 to 7 tube rows to force bypass fluid back into crossflow Stream B.
- Vibration Screening (TEMA Section 5): Always calculate the vortex shedding frequency ($f_v = S_t v / d_o$) and fluid elastic instability constant ($V_{crit}$) to ensure flow velocities do not induce destructive acoustic or mechanical tube vibration.
References & Industry Standards
- Tubular Exchanger Manufacturers Association. (2019). Standards of the Tubular Exchanger Manufacturers Association (10th Edition). TEMA, Tarrytown, NY.
- Bell, K. J. (1981). Delaware Method for Shell-Side Design. In Heat Exchangers: Thermal-Hydraulic Fundamentals and Design, Hemisphere Publishing, pp. 581–618.
- Kern, D. Q. (1950). Process Heat Transfer. McGraw-Hill Book Company, New York.
- Serth, R. W., & Lestina, T. G. (2014). Process Heat Transfer: Principles, Applications and Rules of Thumb (2nd Edition). Academic Press.
- Bowman, R. A., Mueller, A. C., & Nagle, W. M. (1940). Mean Temperature Difference in Design. Transactions of ASME, 62, 283–294.