📐 Engineering Formula & Specification Sheet

Gas Scrubber: Sizing Methodology & Engineering Basis

Design gas scrubbers for mist and droplet removal. Size vessels based on K-factor, evaluate mist eliminator performance, and calculate liquid carryover rates for gas processing applications.

📐 Reviewed by: ChemProCal Engineering Editorial Team
🗓️ Standards: ASME / API / GPSA / ISA
⏱️ Format: Quick Reference Spec Sheet

Purpose: This tool performs rigorous physical sizing based on liquid-vapor separation principles.

Gas Disengagement Methodology: Uses the Souders-Brown equation (v_max = K * sqrt((rho_L - rho_G) / rho_G)) to determine the maximum allowable vapor velocity. The K-factor is dependent on the selected demister.

Geometry & Orientation: The sizing algorithm actively links necessary vapor flow area and required liquid volume against the geometric constraints (Horizontal or Vertical cylinder). It enforces the provided Target L/D as a minimum geometric limit to prevent uneconomical, squat vessel dimensions.

Liquid Inventory: Determines surge capacity using target retention times (e.g. typically 3 minutes for phase separators, 1 minute for KO drums and scrubbers).

Nozzle Screening: Preliminary estimates sizing based on generic ρv² and velocity constraints.

📚 ChemProCal Knowledge Base

Need Complete Mathematical Derivations & Industrial Case Studies?

Explore our in-depth engineering textbook guide: Gas Scrubber Design & Sizing: Theory, Demister Mechanics & Equations. Features step-by-step manual hand calculations, thermodynamic proofs, and commercial simulator benchmarks.

Read Full Theory Guide →
Peer Review & Engineering Accuracy

This specification sheet and its mathematical formulations adhere to internationally recognized process codes (ASME, API, GPSA, TEMA, and ISA). Sizing parameters and default design allowances are cross-referenced with empirical industry design practices.

About This Tool

Sizes vertical vapor-liquid gas scrubbers equipped with wire-mesh mist eliminators or vane packs against Souders-Brown carryover limits (GPSA Section 7, API 12J) and liquid surge holdup times ahead of compressors or catalytic reactors.

Demister Mechanics & Gas Scrubber Design Theory

1. Process Function: Scrubber vs. KO Drum vs. Filter Separator

A Gas Scrubber (often termed a high-efficiency demisting scrubber or suction scrubber) is an engineered vertical vessel designed to remove fine liquid aerosols and solid particulates from gas streams. While a knock-out drum relies purely on open gravity settling to capture large droplets ($\ge 300\text{--}600\,\mu\text{m}$), a gas scrubber incorporates specialized internal separation equipment—most commonly knitted wire mesh pads, vane-pack mist eliminators, or multi-cyclone bundles—to capture droplets down to $8\text{--}10\,\mu\text{m}$ with greater than 99.5% separation efficiency.

Critical Equipment Protection:

Gas scrubbers are installed immediately upstream of centrifugal and reciprocating gas compressors (API 617 / API 618), gas turbine fuel systems, amine sweetening contactors, and molecular sieve dehydration towers, where even trace liquid entrainment causes blade erosion, valve fatigue, amine foaming, or adsorbent poisoning.

2. Droplet Capture Mechanisms in Demister Internals

The separation of micron-scale droplets within a scrubber's internal packing relies on three distinct physical mechanisms:

  1. Inertial Impaction (Dominant for $d_p > 3\text{--}5\,\mu\text{m}$):

    As the gas stream snakes through tightly woven wire filaments or serpentine vane blades, the gas streamlines bend abruptly. Droplets possessing high momentum cannot follow the rapidly curving streamlines and collide with the target wire surface. The efficiency of impaction is characterized by the dimensionless Stokes number:

    $$Stk = \frac{\rho_l d_p^2 v_{gas}}{18 \mu_g d_w}$$

    where $d_w$ is the target wire diameter. When $Stk > 1$, droplet trajectories deviate from streamlines and impact the collector wire.

  2. Direct Interception (Dominant for $1\,\mu\text{m} < d_p < 5\,\mu\text{m}$):

    Droplets following the streamline pass within a distance equal to their radius ($r_p = d_p / 2$) from the collector wire surface, touching and coalescing with the liquid film.

  3. Brownian Diffusion (Dominant for sub-micron aerosols $d_p < 0.5\,\mu\text{m}$):

    Extremely fine droplets exhibit random thermal molecular bombardment (Brownian motion), causing them to wander across gas streamlines and contact fiber surfaces. High-density candle filters utilize diffusion to achieve 99.9% capture of sub-micron oil mists.

3. Souders-Brown Capacity & Demister Sizing

The cross-sectional area of a vertical scrubber is determined by the maximum allowable gas velocity through the mist extractor to prevent re-entrainment. At high gas velocities, liquid that has coalesced inside the mesh pad is sheared off the top surface and re-atomized into the discharge gas.

The maximum superficial gas velocity is governed by the Souders-Brown equation:

$$v_{max} = K_{demister} \sqrt{\frac{\rho_l - \rho_g}{\rho_g}}$$

3.1 Mist Extractor Technology Comparison

Internals Type Base $K_0$ Factor ($m/s$) Base $K_0$ Factor ($ft/s$) Droplet Cutoff ($d_{99}$) Fouling Resistance
Standard Mesh Pad (SS316) $0.107$ $0.35$ $8\text{--}10\,\mu\text{m}$ Low (plugs easily with waxes/solids)
Mesh-Vane Combination $0.122$ $0.40$ $5\text{--}8\,\mu\text{m}$ Moderate
Vane Pack (Chevron) $0.152$ $0.50$ $20\text{--}30\,\mu\text{m}$ High (handles viscous crude / scale)
Axial Cyclonic Tubes $0.200\text{--}0.250$ $0.65\text{--}0.82$ $8\text{--}12\,\mu\text{m}$ Excellent (self-cleaning swirl flow)

3.2 GPSA Section 7 Pressure Derating

At operating pressures exceeding atmospheric ($P > 7\,\text{bar a}$), gas density increases, reducing interfacial surface tension forces that anchor coalesced liquid droplets to the mesh wires. The Gas Processors Suppliers Association (GPSA) mandates derating $K_{SB}$ as a function of operating pressure:

$$K_{derated} = K_0 \cdot \left[1.0 - 0.0001 \cdot (P - 100)\right]\quad (\text{for } P \text{ in psia})$$

In metric units ($P$ in $\text{bar gauge}$):

$$K_{derated} = K_0 \cdot \left[1.0 - 0.00145 \cdot (P - 6.9)\right]$$

For operating pressures above 70 bar g (1000 psig), standard mesh pads can lose up to 30–40% of their effective capacity, requiring larger vessel diameters or switching to vane-axial cyclonic separators.

4. Complete Vertical Vessel Height Hierarchy

The total height ($H_{T-T}$, tangent-to-tangent) of a vertical scrubber is constructed from standard engineering zones defined by API Specification 12J and GPSA Section 7:

  1. Sump Zone ($H_{LLL}$): Distance from bottom tangent line (BTL) to Low Liquid Level (LLL). Typically $250\text{--}400\,\text{mm}$ to prevent vortex formation into the liquid drain nozzle.
  2. Surge / Retention Zone ($H_{LLL}$ to $H_{HLL}$): Liquid volume providing required holdup time ($t_h$):
    • Compressor suction scrubbers: 3 to 5 minutes of peak liquid inflow between normal and high liquid levels.
    • Plant trip volume ($H_{HLL}$ to $H_{HHLL}$): 1 to 2 minutes of surge time to allow automated shutdown before liquid reaches the gas outlet.
  3. Inlet Disengagement Zone ($H_{inlet}$): Distance from High-High Liquid Level (HHLL) to inlet nozzle center. Minimum $1.0 \times D_{inlet}$ or $300\,\text{mm}$.
  4. Primary Gravity Dropout Space: Distance from top of inlet nozzle to bottom of demister pad. Minimum $600\text{--}900\,\text{mm}$ ($24\text{--}36\,\text{in}$) or $0.75 \times D_v$. This allows primary bulk liquid droplets to drop out before loading the mesh pad.
  5. Demister Thickness: Standard mesh pad is $100\text{--}150\,\text{mm}$ ($4\text{--}6\,\text{in}$) thick, supported by grid bars.
  6. Disengagement Head Space: Distance from top of demister pad to top tangent line (TTL). Minimum $300\text{--}450\,\text{mm}$ ($12\text{--}18\,\text{in}$) to ensure uniform gas convergence into the vapor outlet nozzle.

5. Inlet Momentum Control & Feed Devices

To avoid bulk liquid shearing at the inlet, the feed nozzle momentum flux must comply with API/Norsok criteria:

$$\rho_m v_{in}^2 \le 1400\,\text{Pa}\quad (\text{Bare open nozzle})$$ $$\rho_m v_{in}^2 \le 4000\,\text{Pa}\quad (\text{Half-pipe downward baffle plate})$$ $$\rho_m v_{in}^2 \le 6000\text{--}8000\,\text{Pa}\quad (\text{Vane-type inlet distributor / Schoepentoeter})$$

A properly selected Schoepentoeter inlet device gently decelerates the two-phase mixture, shaving off up to 80% of bulk liquid into the lower sump before the gas ascends toward the mesh pad.

6. Step-by-Step Worked Sizing Example (Suction Scrubber)

Size a compressor suction gas scrubber operating under the following process conditions:

  • Gas mass flow rate: $W_g = 65{,}000\,\text{kg/h}$ ($18.06\,\text{kg/s}$)
  • Gas density at $P = 35.0\,\text{bar a}$, $T = 30^\circ\text{C}$: $\rho_g = 28.5\,\text{kg/m}^3$
  • Liquid condensate density: $\rho_l = 740\,\text{kg/m}^3$
  • Gas viscosity: $\mu_g = 1.35 \times 10^{-5}\,\text{Pa}\cdot\text{s}$
  • Liquid entrainment rate: $Q_l = 4.2\,\text{m}^3\text{/h}$ ($0.00117\,\text{m}^3\text{/s}$)
  • Required liquid retention time ($NLL$ to $HLL$): $t_h = 5\,\text{minutes}$
  • Demister selection: Stainless steel mesh pad ($150\,\text{mm}$ thickness, base $K_0 = 0.107\,\text{m/s}$)

Step 1: Calculate Pressure-Derated $K$-Factor

Operating pressure is $P = 35.0\,\text{bar a} = 34.0\,\text{bar g} = 493.1\,\text{psig}$.

$$K_{derated} = 0.107 \times \left[1.0 - 0.0001 \times (493.1 - 100)\right] = 0.107 \times 0.9607 = 0.1028\,\text{m/s}$$

Step 2: Calculate Maximum Allowable Gas Velocity

$$v_{max} = K_{derated} \sqrt{\frac{\rho_l - \rho_g}{\rho_g}} = 0.1028 \times \sqrt{\frac{740 - 28.5}{28.5}} = 0.1028 \times \sqrt{24.965} = 0.5136\,\text{m/s}$$

For design conservatism and turndown margin, select design velocity at 85% of $v_{max}$:

$$v_{design} = 0.85 \times 0.5136 = 0.4365\,\text{m/s}$$

Step 3: Calculate Required Scrubber Internal Diameter

Volumetric gas flow rate:

$$Q_g = \frac{W_g}{\rho_g} = \frac{18.06\,\text{kg/s}}{28.5\,\text{kg/m}^3} = 0.6337\,\text{m}^3\text{/s}$$

Required cross-sectional area:

$$A_{vessel} = \frac{Q_g}{v_{design}} = \frac{0.6337}{0.4365} = 1.4517\,\text{m}^2$$

Vessel inside diameter ($D_v$):

$$D_v = \sqrt{\frac{4 \times 1.4517}{\pi}} = 1.359\,\text{m}$$

Select standard nominal shell internal diameter: $D_v = 1400\,\text{mm}$ ($1.40\,\text{m}$ / 55 in).

Actual cross-sectional area: $A_{actual} = \frac{\pi}{4}(1.40)^2 = 1.539\,\text{m}^2$.

Actual operating velocity: $v_{act} = \frac{0.6337}{1.539} = 0.4117\,\text{m/s}$ (78% of $v_{max}$, optimal operating window).

Step 4: Calculate Liquid Level Heights

Required surge volume for 5 minutes holdup:

$$V_{surge} = 4.2\,\text{m}^3\text{/h} \times \left(\frac{5}{60}\,\text{h}\right) = 0.350\,\text{m}^3$$

Height between NLL and HLL:

$$H_{surge} = \frac{V_{surge}}{A_{actual}} = \frac{0.350}{1.539} = 0.227\,\text{m} \approx 230\,\text{mm}$$

Adding standard zones:

  • Bottom tangent to LLL ($H_{LLL}$): $300\,\text{mm}$
  • LLL to NLL (alarm buffer): $150\,\text{mm}$
  • NLL to HLL ($H_{surge}$): $230\,\text{mm}$
  • HLL to HHLL (shutdown margin, 2 min): $100\,\text{mm}$
  • HHLL to inlet nozzle center: $300\,\text{mm}$
  • Inlet nozzle to bottom of demister: $900\,\text{mm}$ (primary disengagement)
  • Demister pad thickness: $150\,\text{mm}$
  • Demister top to top tangent (TTL): $400\,\text{mm}$

Total Tangent-to-Tangent Height ($H_{T-T}$):

$$H_{T-T} = 300 + 150 + 230 + 100 + 300 + 900 + 150 + 400 = 2530\,\text{mm} = 2.53\,\text{m}$$

Slenderness aspect ratio: $H_{T-T} / D_v = 2.53 / 1.40 = 1.81$ (ideal for vertical pressure vessels).

7. Operational Troubleshooting & Differential Pressure Monitoring

Symptom Root Cause Corrective Action
$\Delta P_{mesh} > 3.0\,\text{kPa}$ (High $\Delta P$) Fouling by heavy wax, scale, or hydrates in wire mesh pores Initiate hot solvent wash or steam-out; replace mesh with vane pack if chronic
Liquid carryover downstream Operating above $v_{max}$ (re-entrainment) or plugged drain line Throttle gas rate; inspect automated level dump valve and drain nozzle
Level transmitter signal hunting Surface boiling or high inlet turbulence disturbing liquid level Install internal stilling well around bridle and verify inlet baffle integrity

8. ChemProCal Integration

Perform complete scrubber verification using ChemProCal calculation modules:

Frequently Asked Questions

Who should use the Gas Scrubber?

This tool is designed for process engineers, mechanical engineers, plant operators, and engineering students who need a reliable method to perform fluid mechanics calculations.

Can this calculator replace rigorous simulation software?

No. While this tool is highly accurate for specific unit operations and preliminary design, complex integrated plant design and safety-critical relief calculations should always be verified using certified commercial simulation software (e.g., Aspen HYSYS, UniSim).

Are the results suitable for procurement and fabrication?

The results provided are for estimation and engineering validation purposes. Final equipment sizing and procurement must always be verified by the equipment manufacturer or vendor, who will apply their proprietary performance curves and mechanical tolerances.
Tool Units

Input / Output Units

Configure global unit system preset or individual parameter dimensions.

CALCULATED RESULT