Natural Gas Thermodynamics Worked Example Cryogenic Molecular Sieve Dehydration Zeolite 4A LNG

Worked Example: Sizing a Molecular Sieve Dehydration Unit for Cryogenic LNG Feed Drying (< 0.1 ppmv)

Comprehensive engineering design sizing a 2-bed Type 4A molecular sieve adsorption dehydrator, including desiccant inventory, vessel geometry, Ergun pressure drop, and regeneration thermal duty.

Published
October 17, 2026
Reading Time
~6 Minutes
Technical Review
Process Design Engineer (B.Tech Chemical Engineering, 5+ Yrs Experience)
📑 Table of Contents (Tap to view sections)

    Deep cryogenic natural gas processing—such as turboexpander NGL extraction ($-85^\circ\text{C}$ to $-105^\circ\text{C}$) and baseload Liquefied Natural Gas (LNG) liquefaction ($-162^\circ\text{C}$)—mandates feed gas moisture levels below $0.1\text{ ppmv}$ ($< 0.005\text{ lb/MMSCF}$). At these extreme temperatures, residual moisture freezes into solid ice crystals within brazed aluminum plate-fin heat exchangers (cold boxes) and turboexpander nozzles, causing catastrophic differential pressure spikes and plant trips.

    This worked example presents the complete process engineering design and equipment sizing for a 2-bed Type 4A molecular sieve dehydration unit treating $10.0\text{ MMSCFD}$ at $60.0\text{ barg}$, detailing water mass balance, zeolite inventory, vessel diameter, Ergun pressure drop, and regeneration thermal balances.


    1. Design Basis & Operating Parameters

    A front-end engineering design (FEED) study for an LNG feed gas pre-treatment unit defines the following parameters:

    Inlet Feed Gas Conditions:

    • Gas Flow Rate ($Q$): $10.0\text{ MMSCFD}$ ($11,798.7\text{ Sm}^3/\text{h}$)
    • Operating Pressure ($P$): $60.0\text{ barg}$ ($61.01\text{ bar(a)} = 884.9\text{ psia}$)
    • Inlet Temperature ($T$): $30.0^\circ\text{C}$ ($86.0^\circ\text{F} = 303.15\text{ K}$)
    • Gas Specific Gravity ($G$): $0.65$ ($\text{MW} = 18.83\text{ kg/kmol}$)
    • Gas Compressibility ($Z$): $0.862$
    • Gas Density ($\rho_g$): $57.2\text{ kg/m}^3$ ($3.571\text{ lb/ft}^3$)

    Adsorption System Parameters:

    • System Architecture: 2-Bed System (1 Bed Drying / 1 Bed Regenerating & Cooling)
    • Adsorption Cycle Time ($t_{cycle}$): $8.0\text{ hours}$
    • Desiccant Selected: Type 4A Synthetic Zeolite (Sodium Aluminosilicate, $4.0\text{ \AA}$ pore)
    • Pellet Geometry: $1/8\text{"}$ (3.2 mm) spherical beads ($\epsilon = 0.38$)
    • Desiccant Bulk Density ($\rho_b$): $720.0\text{ kg/m}^3$ ($45.0\text{ lb/ft}^3$)
    • Target Water Specification: $\mathbf{\le 0.1\text{ ppmv}}$ ($-100^\circ\text{C}$ atmospheric dew point)
    • Regeneration Temperature ($T_{reg}$): $260.0^\circ\text{C}$ ($500.0^\circ\text{F}$)

    2. Step 1: Water Balance & Adsorption Mass Load

    A. Inlet Gas Water Content ($W_{in}$):

    From the Bukacek correlation for sweet natural gas at $60.0\text{ barg}$ and $30.0^\circ\text{C}$:

    B. Hourly and Cycle Water Removal Load:

    For $10.0\text{ MMSCFD}$ throughput:

    Over an $8.0\text{-hour}$ drying cycle:


    3. Step 2: Desiccant Inventory & Bed Volume

    Fresh Type 4A molecular sieve exhibits an equilibrium water capacity of $\approx 20\text{ wt}\%$. Per GPSA Figure 20-71, the design useful capacity ($\Delta q$) is derated for hydrothermal aging (3-year lifecycle) and mass transfer zone (MTZ) effects:

    Required Desiccant Mass per Bed:

    Total desiccant inventory for two beds $= \mathbf{4,410\text{ lb}}$ ($2,000\text{ kg}$).

    Packed Bed Volume:


    4. Step 3: Vessel Sizing & Superficial Velocity Limits

    In downward-flow dehydration service, bed diameter is governed by superficial gas velocity $v_s$ to prevent gas channeling and keep velocity safely below the Ledoux fluidization threshold ($0.35\text{ m/s}$):

    Actual Volumetric Gas Flow Rate:

    Selecting Bed Diameter:

    Standard vessel sizing selects an inside diameter of $36.0\text{ inches}$ ($0.914\text{ m}$): * Cross-sectional area: $A_{bed} = \frac{\pi}{4} (0.914)^2 = \mathbf{0.6567\text{ m}^2}$ ($7.069\text{ ft}^2$) * Superficial velocity: (Target design range: $10 - 35\text{ ft/min}$ — Safe from fluidization)

    Bed Height & Aspect Ratio:

    Aspect ratio $L/D = \frac{2.12}{0.914} = \mathbf{2.32}$ (GPSA optimal range: $2.0 - 4.0$).


    5. Step 4: Ergun Packed Bed Pressure Drop

    Pressure drop across clean desiccant beds is calculated via the Ergun equation combining viscous and inertial drag ($\epsilon = 0.38, d_p = 0.0032\text{ m}, \mu = 1.35 \times 10^{-5}\text{ Pa}\cdot\text{s}$):

    1. Viscous term: $150 \frac{(0.62)^2}{(0.38)^3} \frac{(1.35 \times 10^{-5})(0.069)}{(0.0032)^2} = \mathbf{95.4\text{ Pa/m}}$
    2. Inertial term: $1.75 \frac{0.62}{(0.38)^3} \frac{(57.2)(0.069)^2}{0.0032} = \mathbf{168.3\text{ Pa/m}}$

    Total pressure gradient: (GPSA limit: $< 0.33\text{ psi/ft}$ to prevent bed crushing)

    Total bed pressure drop:


    6. Step 5: Thermal Regeneration (TSA) Balance

    Regeneration is a 3-step cycle: Heating (4.4 hours), Cooling (2.8 hours), and Pressure Equalization (0.8 hours).

    Thermal Energy Requirements:

    1. Water Desorption Latent Heat ($\Delta H_{des} = 4,186\text{ kJ/kg}$):

    2. Desiccant Sensible Heat ($C_p = 1.05\text{ kJ/kg}\cdot\text{K}, \Delta T = 230\text{ K}$):

    3. Vessel Steel Sensible Heat ($M_{steel} \approx 1,400\text{ kg}, C_p = 0.50, \Delta T_{eff} = 161\text{ K}$):

    4. Heat Losses (10%):

    Total Regeneration Heat Required:

    Regeneration Heater Duty:

    Over $t_{heating} = 4.4\text{ hours}$ ($15,840\text{ seconds}$):

    Regeneration Gas Flow Rate:


    7. Equipment Sizing Summary

    Equipment Parameter Engineering Value Unit Design Compliance Status
    Active Beds / Total Beds 1 / 2 Beds 1 drying, 1 regeneration/cooling
    Zeolite Desiccant Type Type 4A Zeolite $4.0\text{ \AA}$ crystalline framework
    Desiccant Mass per Bed $\mathbf{1,000.2}$ kg (2,205 lb) Sized for 3-year aging capacity
    Vessel Inside Diameter $\mathbf{36.0}$ inches (0.914 m) Anti-fluidization compliant
    Packed Bed Height $\mathbf{2.12}$ meters (6.94 ft) Aspect ratio $L/D = 2.32$
    Superficial Gas Velocity $\mathbf{0.069}$ m/s (13.7 ft/min) $< 0.35\text{ m/s}$ Ledoux limit
    Ergun Bed Pressure Drop $\mathbf{0.038}$ bar (0.55 psi) $< 0.33\text{ psi/ft}$ safe threshold
    Outlet Moisture Level $\mathbf{< 0.1}$ ppmv Cryogenic LNG specification met
    Regen Heater Duty $\mathbf{54.5}$ kW (0.19 MMBtu/h) Desorption + Sensible thermal duty
    Regen Gas Requirement $\mathbf{5.3\%}$ of feed gas Recycled to inlet separator
    
    Apply This Fundamental

    Molecular Sieve Cryogenic Dehydration Sizer

    Apply this methodology directly in the ChemProCal calculator.

    Open Calculator →

    References

    • GPSA Engineering Data Book, Section 20 - Dehydration (14th Edition, Gas Processors Suppliers Association) - Book
    • Ergun, S. - Fluid Flow through Packed Columns (Chemical Engineering Progress, Vol. 48, 1952) - Paper [Link ↗]
    • Ruthven, D.M. - Principles of Adsorption and Adsorption Processes (John Wiley & Sons, 1984) - Book
    ⚡ Interactive Estimator

    Live Gas Pipeline Velocity & Momentum Flux Estimator

    Adjust parameters below to test the methodology equations in real time before running full simulations:

    Actual Gas Velocity ($v$) 8.2 m/s
    Momentum Flux ($\rho v^2$) 975 Pa
    Operating Density ($\rho$) 14.5 kg/m³
    ✓ Velocity & kinetic momentum within acceptable continuous gas limits.

    Engineering Standards & Peer-Review Governance

    Authored & Verified by Process Design Engineer (B.Tech Chemical Engineering, 5+ Yrs Experience)

    Molecular sieve sizing complies with GPSA Engineering Data Book Section 20 design standards. Fluidization velocities are governed by Ledoux criteria and packed bed friction is modeled via the Ergun equation.

    Domain Thermodynamics
    Governing Standards GPSA Engineering Data Book Section 20, Ergun (1952), Ledoux Fluidization Criteria, ASME Section VIII Div. 1
    Content Classification Worked Example
    Verification ✓ Benchmark Validated