📑 Table of Contents (Tap to view sections)
Deep cryogenic natural gas processing—such as turboexpander NGL extraction ($-85^\circ\text{C}$ to $-105^\circ\text{C}$) and baseload Liquefied Natural Gas (LNG) liquefaction ($-162^\circ\text{C}$)—mandates feed gas moisture levels below $0.1\text{ ppmv}$ ($< 0.005\text{ lb/MMSCF}$). At these extreme temperatures, residual moisture freezes into solid ice crystals within brazed aluminum plate-fin heat exchangers (cold boxes) and turboexpander nozzles, causing catastrophic differential pressure spikes and plant trips.
This worked example presents the complete process engineering design and equipment sizing for a 2-bed Type 4A molecular sieve dehydration unit treating $10.0\text{ MMSCFD}$ at $60.0\text{ barg}$, detailing water mass balance, zeolite inventory, vessel diameter, Ergun pressure drop, and regeneration thermal balances.
1. Design Basis & Operating Parameters
A front-end engineering design (FEED) study for an LNG feed gas pre-treatment unit defines the following parameters:
Inlet Feed Gas Conditions:
- Gas Flow Rate ($Q$): $10.0\text{ MMSCFD}$ ($11,798.7\text{ Sm}^3/\text{h}$)
- Operating Pressure ($P$): $60.0\text{ barg}$ ($61.01\text{ bar(a)} = 884.9\text{ psia}$)
- Inlet Temperature ($T$): $30.0^\circ\text{C}$ ($86.0^\circ\text{F} = 303.15\text{ K}$)
- Gas Specific Gravity ($G$): $0.65$ ($\text{MW} = 18.83\text{ kg/kmol}$)
- Gas Compressibility ($Z$): $0.862$
- Gas Density ($\rho_g$): $57.2\text{ kg/m}^3$ ($3.571\text{ lb/ft}^3$)
Adsorption System Parameters:
- System Architecture: 2-Bed System (1 Bed Drying / 1 Bed Regenerating & Cooling)
- Adsorption Cycle Time ($t_{cycle}$): $8.0\text{ hours}$
- Desiccant Selected: Type 4A Synthetic Zeolite (Sodium Aluminosilicate, $4.0\text{ \AA}$ pore)
- Pellet Geometry: $1/8\text{"}$ (3.2 mm) spherical beads ($\epsilon = 0.38$)
- Desiccant Bulk Density ($\rho_b$): $720.0\text{ kg/m}^3$ ($45.0\text{ lb/ft}^3$)
- Target Water Specification: $\mathbf{\le 0.1\text{ ppmv}}$ ($-100^\circ\text{C}$ atmospheric dew point)
- Regeneration Temperature ($T_{reg}$): $260.0^\circ\text{C}$ ($500.0^\circ\text{F}$)
2. Step 1: Water Balance & Adsorption Mass Load
A. Inlet Gas Water Content ($W_{in}$):
From the Bukacek correlation for sweet natural gas at $60.0\text{ barg}$ and $30.0^\circ\text{C}$:
B. Hourly and Cycle Water Removal Load:
For $10.0\text{ MMSCFD}$ throughput:
Over an $8.0\text{-hour}$ drying cycle:
3. Step 2: Desiccant Inventory & Bed Volume
Fresh Type 4A molecular sieve exhibits an equilibrium water capacity of $\approx 20\text{ wt}\%$. Per GPSA Figure 20-71, the design useful capacity ($\Delta q$) is derated for hydrothermal aging (3-year lifecycle) and mass transfer zone (MTZ) effects:
Required Desiccant Mass per Bed:
Total desiccant inventory for two beds $= \mathbf{4,410\text{ lb}}$ ($2,000\text{ kg}$).
Packed Bed Volume:
4. Step 3: Vessel Sizing & Superficial Velocity Limits
In downward-flow dehydration service, bed diameter is governed by superficial gas velocity $v_s$ to prevent gas channeling and keep velocity safely below the Ledoux fluidization threshold ($0.35\text{ m/s}$):
Actual Volumetric Gas Flow Rate:
Selecting Bed Diameter:
Standard vessel sizing selects an inside diameter of $36.0\text{ inches}$ ($0.914\text{ m}$): * Cross-sectional area: $A_{bed} = \frac{\pi}{4} (0.914)^2 = \mathbf{0.6567\text{ m}^2}$ ($7.069\text{ ft}^2$) * Superficial velocity: (Target design range: $10 - 35\text{ ft/min}$ — Safe from fluidization)
Bed Height & Aspect Ratio:
Aspect ratio $L/D = \frac{2.12}{0.914} = \mathbf{2.32}$ (GPSA optimal range: $2.0 - 4.0$).
5. Step 4: Ergun Packed Bed Pressure Drop
Pressure drop across clean desiccant beds is calculated via the Ergun equation combining viscous and inertial drag ($\epsilon = 0.38, d_p = 0.0032\text{ m}, \mu = 1.35 \times 10^{-5}\text{ Pa}\cdot\text{s}$):
- Viscous term: $150 \frac{(0.62)^2}{(0.38)^3} \frac{(1.35 \times 10^{-5})(0.069)}{(0.0032)^2} = \mathbf{95.4\text{ Pa/m}}$
- Inertial term: $1.75 \frac{0.62}{(0.38)^3} \frac{(57.2)(0.069)^2}{0.0032} = \mathbf{168.3\text{ Pa/m}}$
Total pressure gradient: (GPSA limit: $< 0.33\text{ psi/ft}$ to prevent bed crushing)
Total bed pressure drop:
6. Step 5: Thermal Regeneration (TSA) Balance
Regeneration is a 3-step cycle: Heating (4.4 hours), Cooling (2.8 hours), and Pressure Equalization (0.8 hours).
Thermal Energy Requirements:
-
Water Desorption Latent Heat ($\Delta H_{des} = 4,186\text{ kJ/kg}$):
-
Desiccant Sensible Heat ($C_p = 1.05\text{ kJ/kg}\cdot\text{K}, \Delta T = 230\text{ K}$):
-
Vessel Steel Sensible Heat ($M_{steel} \approx 1,400\text{ kg}, C_p = 0.50, \Delta T_{eff} = 161\text{ K}$):
-
Heat Losses (10%):
Total Regeneration Heat Required:
Regeneration Heater Duty:
Over $t_{heating} = 4.4\text{ hours}$ ($15,840\text{ seconds}$):
Regeneration Gas Flow Rate:
7. Equipment Sizing Summary
| Equipment Parameter | Engineering Value | Unit | Design Compliance Status |
|---|---|---|---|
| Active Beds / Total Beds | 1 / 2 | Beds | 1 drying, 1 regeneration/cooling |
| Zeolite Desiccant Type | Type 4A | Zeolite | $4.0\text{ \AA}$ crystalline framework |
| Desiccant Mass per Bed | $\mathbf{1,000.2}$ | kg (2,205 lb) | Sized for 3-year aging capacity |
| Vessel Inside Diameter | $\mathbf{36.0}$ | inches (0.914 m) | Anti-fluidization compliant |
| Packed Bed Height | $\mathbf{2.12}$ | meters (6.94 ft) | Aspect ratio $L/D = 2.32$ |
| Superficial Gas Velocity | $\mathbf{0.069}$ | m/s (13.7 ft/min) | $< 0.35\text{ m/s}$ Ledoux limit |
| Ergun Bed Pressure Drop | $\mathbf{0.038}$ | bar (0.55 psi) | $< 0.33\text{ psi/ft}$ safe threshold |
| Outlet Moisture Level | $\mathbf{< 0.1}$ | ppmv | Cryogenic LNG specification met |
| Regen Heater Duty | $\mathbf{54.5}$ | kW (0.19 MMBtu/h) | Desorption + Sensible thermal duty |
| Regen Gas Requirement | $\mathbf{5.3\%}$ | of feed gas | Recycled to inlet separator |
Molecular Sieve Cryogenic Dehydration Sizer
Apply this methodology directly in the ChemProCal calculator.
Open Calculator →References
- GPSA Engineering Data Book, Section 20 - Dehydration (14th Edition, Gas Processors Suppliers Association) - Book
- Ergun, S. - Fluid Flow through Packed Columns (Chemical Engineering Progress, Vol. 48, 1952) - Paper [Link ↗]
- Ruthven, D.M. - Principles of Adsorption and Adsorption Processes (John Wiley & Sons, 1984) - Book
Live Gas Pipeline Velocity & Momentum Flux Estimator
Adjust parameters below to test the methodology equations in real time before running full simulations: