📑 Table of Contents (Tap to view sections)
1. Problem Statement & Compressor Specifications
A sales gas centrifugal compressor stage in an LNG feed-gas preparation plant compresses treated dry natural gas. During a plant turndown trial, the operations team needs to determine whether the compressor can run safely without opening the antisurge recycle valve.
Process & Gas Parameters
- Gas Composition: Methane-rich sales gas ($MW = 17.50\text{ g/mol}$, $SG = 0.604$)
- Specific Heat Ratio ($k = C_p/C_v$): $1.295$
- Suction Pressure ($P_1$): $25.0\text{ bar abs}$ ($24.01\text{ barg}$)
- Suction Temperature ($T_1$): $35.0\text{ }^\circ\text{C}$ ($308.15\text{ K}$)
- Target Discharge Pressure ($P_2$): $65.0\text{ bar abs}$ ($63.99\text{ barg}$)
- Pressure Ratio ($r_p$): $65.0 / 25.0 = 2.60$
- Polytropic Efficiency ($\eta_p$): $82.0\%$ ($0.82$)
- Mechanical Efficiency ($\eta_m$): $97.5\%$ ($0.975$)
- Compressor Design Speed ($100\%$ MCS): $10,500\text{ RPM}$
- Design Suction Volumetric Flow ($Q_{rated}$): $6,000\text{ m}^3/\text{h}$ ($1.667\text{ m}^3/\text{s}$)
Turndown Condition to Evaluate
- Operating Flow: $Q_{act} = 3,850\text{ m}^3/\text{h}$
- Operating Speed: $90\%\text{ Speed}$ ($9,450\text{ RPM}$)
- OEM Aerodynamic Surge Flow at 90% Speed: $Q_{surge}(90\%) = 3,250\text{ m}^3/\text{h}$
Engineering Questions
- What is the required polytropic head ($H_p$) and expected discharge temperature ($T_2$)?
- What is the required shaft power ($P_{shaft}$) at rated conditions?
- What is the dynamic Surge Margin ($SM\%$) at the 90% speed turndown condition?
- Is the compressor operating safely, or does the antisurge valve need to recycle gas?
2. Step-by-Step Engineering Calculations
Step 1: Polytropic Temperature Exponent ($m$) & Discharge Temperature
The polytropic temperature exponent $m$ is calculated from the isentropic exponent $k$ and polytropic efficiency $\eta_p$:
The polytropic volume exponent $n$ is:
The expected discharge temperature $T_2$ is: The discharge temperature is well below the API 617 maximum allowable limit of $150\text{ }^\circ\text{C}$ for centrifugal gas compressors.
Step 2: Average Compressibility Factor ($Z_{avg}$) & Specific Gas Constant
Evaluating real gas compressibility at suction ($25\text{ bar}$, $35\text{ }^\circ\text{C}$) and discharge ($65\text{ bar}$, $128.7\text{ }^\circ\text{C}$):
The specific gas constant for natural gas ($MW = 17.50\text{ kg/kmol}$):
Step 3: Polytropic Head Calculation (Schultz Method)
Applying the Schultz polytropic work equation (with $f_{Schultz} \approx 1.005$):
Converting head into meters of fluid column ($g = 9.80665\text{ m/s}^2$):
Step 4: Gas Density, Mass Flow & Shaft Power
Suction gas density ($\rho_1$):
At design rated flow ($Q_1 = 6,000\text{ m}^3/\text{h} = 1.667\text{ m}^3/\text{s}$):
Gas aerodynamic power ($P_{gas}$):
Shaft driver power (including mechanical and seal losses):
Step 5: Surge Margin & Turndown Stability Evaluation
At the turndown test condition: * Operating Speed: $N = 90\%$ ($9,450\text{ RPM}$) * Operating Actual Suction Flow: $Q_{act} = 3,850\text{ m}^3/\text{h}$ * OEM Surge Flow at 90% Speed: $Q_{surge}(90\%) = 3,250\text{ m}^3/\text{h}$
Calculating the Dynamic Surge Margin ($SM\%$):
Checking against API 617 Criteria & Surge Control Line (SCL): * Minimum API 617 Continuous Operating Margin: $10.0\%$ * Typical Facility Surge Control Margin ($SM_{SCL}$): $10.0\%$ to $12.0\%$ * SCL Flow Threshold:
Comparing operating flow against SCL:
3. Engineering Assessment & Operational Conclusions
| Operating Parameter | Rated Condition (100% MCS) | Turndown Condition (90% Speed) | Status / API 617 Compliance |
|---|---|---|---|
| Suction Flow ($Q_1$) | $6,000\text{ m}^3/\text{h}$ | $3,850\text{ m}^3/\text{h}$ | 35.8% Turndown |
| Polytropic Head ($H_p$) | $15,576\text{ m}$ | $12,616\text{ m}$ ($H \propto N^2$) | Normal Off-Design |
| Pressure Ratio ($r_p$) | $2.60$ | $2.28$ | Matches Reduced Pipeline Load |
| Shaft Power ($P_{shaft}$) | $5,790\text{ kW}$ | $3,480\text{ kW}$ | Within Driver Envelope |
| Dynamic Surge Margin ($SM\%$) | $38.2\%$ | $15.58\%$ | STABLE (Passes $\ge 10\%$ API criteria) |
| Antisurge Recycle Valve | Closed ($0\%$) | Closed ($0\%$) | Recycle NOT required |
Operational Recommendation: The compressor is operating safely in stable aerodynamic flow with a healthy $15.58\%$ surge margin ($+275\text{ m}^3/\text{h}$ above the surge control line). No antisurge recycle is required, saving significant compression power and avoiding parasitic discharge gas recirculation.
Compressor Power & Sizing
Apply this methodology directly in the ChemProCal calculator.
Open Calculator →References
- API Standard 617: Axial and Centrifugal Compressors and Expander-compressors (8th Edition, American Petroleum Institute, 2014) - Standard [Link ↗]
- ASME PTC 10: Performance Test Code on Compressors and Exhausters (American Society of Mechanical Engineers, 2018) - Standard [Link ↗]
- Schultz, J.M. - The Polytropic Analysis of Centrifugal Compressors (Journal of Engineering for Power, ASME, 84(1), 69-) - Paper [Link ↗]
Live Joukowsky Water Hammer & Pressure Surge Estimator