NPS 4.0" Schedule 40 Pipe Dimensions
Standard Industrial Pipe Dimensions
Inner Diameter
Outer Diameter
Wall Thickness
Flow Velocity Calculator
Instantly calculate the fluid velocity inside this 4.0" Sch 40 pipe based on volumetric flow rate.
Hydraulic Analysis
Take these exact dimensions into our rigorous hydraulic tools for pressure drop and compressible flow analysis.
ASME B36.10M Common Industrial Pipe Schedule Reference (NPS 1" – 12")
Standard carbon-steel outer diameters (OD), inner diameters (ID), and nominal wall thicknesses (t) in millimeters for quick hydraulic velocity and mechanical sizing checks:
| NPS (in) | OD (mm) | Sch 10 ID / t (mm) | Sch 40 / STD ID / t (mm) | Sch 80 / XS ID / t (mm) |
|---|---|---|---|---|
| 1" | 33.4 mm | 27.9 / 2.77 | 26.6 / 3.38 | 24.3 / 4.55 |
| 2" | 60.3 mm | 54.8 / 2.77 | 52.5 / 3.91 | 49.2 / 5.54 |
| 3" | 88.9 mm | 82.8 / 3.05 | 77.9 / 5.49 | 73.7 / 7.62 |
| 4" | 114.3 mm | 108.2 / 3.05 | 102.3 / 6.02 | 97.2 / 8.56 |
| 6" | 168.3 mm | 161.5 / 3.4 | 154.1 / 7.11 | 146.4 / 10.97 |
| 8" | 219.1 mm | 211.6 / 3.76 | 202.7 / 8.18 | 193.7 / 12.7 |
| 10" | 273.0 mm | 264.6 / 4.19 | 254.5 / 9.27 | 242.8 / 15.09 |
| 12" | 323.8 mm | 314.7 / 4.57 | 303.2 / 10.31 | 288.8 / 17.48 |
Pipe Sizing Methodology & Engineering Basis
1. Calculation Scope & Governing Equations
This reference sheet sizes and checks pipe wall thickness, schedule rating, and hydraulic cross-sectional area per ASME B36.10M / B36.19M and ASME B31.3 Process Piping Code.
2. Standard Velocity Criteria (Industrial Practice)
| Fluid Service | Recommended Velocity Range | Allowable Pressure Drop Gradient |
|---|---|---|
| Pump Suction (Liquid) | 0.6 – 1.5 m/s (2 – 5 ft/s) | ≤ 0.05 – 0.10 bar/100m; prevents cavitation. |
| Pump Discharge (Liquid) | 1.5 – 3.0 m/s (5 – 10 ft/s) | 0.15 – 0.40 bar/100m (Economic optimum). |
| Process Gas (High Pressure > 10 bar) | 10 – 25 m/s (30 – 80 ft/s) | 0.05 – 0.20 bar/100m; noise and erosion limited. |
| Superheated Steam | 30 – 50 m/s (100 – 160 ft/s) | 0.10 – 0.35 bar/100m. |
3. Engineering Assumptions & Boundary Limits
- Corrosion Allowance: Carbon steel hydrocarbon systems default to $C_A = 1.5–3.0\text{ mm}$ (1/16 to 1/8 in). Stainless steel systems default to $C_A = 0\text{ mm}$.
- Mill Underrun: Standard seamless pipe allows $-12.5\%$ mill wall underrun per ASTM A106/A53. Design thickness must incorporate this factor.
About This Tool
Industrial piping sizing requires precise mechanical cross-sectional dimensions across standard nominal pipe sizes (NPS) and schedules. This specification database and calculator adheres to ASME B36.10M (Welded and Seamless Wrought Steel Pipe) and ASME B36.19M (Stainless Steel Pipe), providing exact internal diameters, wall thicknesses, flow areas, and ASME B31.3 internal pressure containment ratings.
1. ASME B36.10M & B36.19M Dimensional Standard
For piping sizes NPS 1/8 (DN 6) through NPS 12 (DN 300), the Nominal Pipe Size corresponds to an internal designation; the Outside Diameter (OD) is fixed regardless of schedule thickness. For NPS 14 and above, the outside diameter is exactly equal to the nominal size (e.g., NPS 16 pipe has an exact $OD = 16.000\text{ in} = 406.4\text{ mm}$).
Wall thickness designations range from Standard (STD), Extra Strong (XS), and Double Extra Strong (XXS) to schedule numbers ($Schedule\ 10, 20, 30, 40, 60, 80, 100, 120, 140, 160$) based on the historic Barlow pressure formula: $Schedule \approx 1000 \cdot \frac{P}{S}$.
2. Minimum Wall Thickness for Internal Pressure (ASME B31.3)
Under the ASME B31.3 Process Piping Code (Paragraph 304.1.2), the required design wall thickness ($t$) to contain internal design pressure ($P$) is calculated as:
$$ t = \frac{P D}{2 (S E W + P Y)} + c $$
Where:
- D = Outside diameter of the pipe.
- S = Allowable stress value for the material from ASME B31.3 Table A-1 at design temperature (e.g., $20,000\text{ psi}$ for ASTM A106 Grade B carbon steel at $100^\circ\text{F}$).
- E = Quality factor from Table A-1A/A-1B ($E = 1.00$ for seamless pipe; $E = 0.85$ for ERW pipe).
- W = Weld joint strength reduction factor ($W = 1.0$ at temperatures below creep range).
- Y = Material coefficient from Table 304.1.1 ($Y = 0.4$ for ferritic steels at $T \le 900^\circ\text{F}$).
- c = Mechanical allowances: sum of corrosion allowance (typically $1.5\text{ to }3.0\text{ mm}$ for carbon steel), thread depth, and mill manufacturing undertolerance (typically $12.5\%$).