ChemProCal
Knowledge Base + New Calculation Login Sign Up
ChemProCal • Heat Transfer • Kettle & Thermosiphon Reboiler Sizer (TEMA K-Shell / API 660)
HEAT TRANSFER

Kettle & Thermosiphon Reboiler Sizer (TEMA K-Shell / API 660)

Size TEMA Type K kettle reboilers and vertical thermosiphon reboilers per API 660 and ASME Section VIII. Model nucleate pool boiling, Mostinski critical heat flux (CHF burnout), Souders-Brown vapor space disengagement, weir height, and natural circulation driving head vs loop friction.


⚡ Industrial Presets:

1. Reboiler Type & Process Boiling Stream

2. Heating Medium Utility (Tubeside for Kettle / Shellside for Thermosiphon)

3. Exchanger Tube Bundle Geometry (TEMA / API 660)

4. TEMA K-Shell Kettle Specifics: Vapor Disengagement & Weir (API 660)

Reboiler Sizing & Thermal-Hydraulic Rating Results

API Standard 660 / TEMA 10th Edition / ASME Section VIII Div 1 Sizing Engine
SUCCESS
DYNAMIC REBOILER CAD STUDIO TEMA Type K Kettle Elevation & Vapor Disengagement Cross-Section
Burnout Safety: --% Shell ID: -- mm
Thermal Duty
-- kW
Heat Flux
-- W/m²
CHF Burnout Limit
-- W/m²
Vapor Disengagement
-- mm
Circulation / Head
--
REQUIRED SURFACE AREA
-- m²
Installed: -- m² (--% margin)
OVERALL U-VALUE (DIRTY)
-- W/m²·K
Clean U: -- W/m²·K
OPERATING HEAT FLUX
-- W/m²
Flux Ratio: -- (Limit ≤ 0.70)
STEAM / UTILITY DEMAND
-- kg/h
ΔT_lm: -- °C

Thermal Duty, Heat Transfer Coefficients & Critical Heat Flux

Thermal / Mechanical Parameter Calculated Metric Value US Customary Unit Design Criterion / Standard
Total Heat Duty (Q) -- kW -- MMBtu/hr Latent boiling + sensible feed duty
Effective Mean Temp Difference (ΔT_lm) -- °C -- °F Pure counter-flow boiling LMTD (Ft = 1.0)
Nucleate Pool Boiling Coeff. (h_nb) -- W/m²·K -- Btu/hr·ft²·°F Mostinski / Cooper nucleate boiling formulation
Heating Medium Coeff. (h_heating) -- W/m²·K -- Btu/hr·ft²·°F Steam condensation / hot oil forced convection
Overall Heat Transfer Coeff. (U_dirty) -- W/m²·K -- Btu/hr·ft²·°F Reciprocal sum with fouling resistances
Tube Count & Bundle Diameter (D_b) -- tubes, -- mm -- in TEMA bundle layout with square/triangular pitch
Single Cylinder Critical Heat Flux (q''_crit) -- W/m² -- Btu/hr·ft² Kutateladze-Zuber pool boiling maximum flux
Palen-Small Bundle Burnout Factor (ψ_b) -- -- Bundle vapor escape geometric restriction factor
Bundle Burnout Limit (q''_max,bundle) -- W/m² -- Btu/hr·ft² Critical film boiling transition threshold
Design Heat Flux Limit (70% CHF) -- W/m² -- Btu/hr·ft² API 660 / GPSA recommended maximum safe flux
Standards: TEMA 10th Ed. • API 660 • ASME Section VIII Div 1 • GPSA Sec 9

📐 Engineering Formula & Specification Sheet

Kettle & Thermosiphon Reboiler Sizer (TEMA K-Shell / API 660): Sizing Methodology & Engineering Basis

Size TEMA Type K kettle reboilers and vertical thermosiphon reboilers per API 660 and ASME Section VIII. Model nucleate pool boiling, Mostinski critical heat

📐 Reviewed by: ChemProCal Engineering Editorial Team
🗓️ Standards: ASME / API / GPSA / ISA
⏱️ Format: Quick Reference Spec Sheet

1. Calculation Scope & Governing Equations

This specification sheet provides thermal-hydraulic rating and mechanical sizing for TEMA Type K Kettle Reboilers and Vertical Thermosiphon Reboilers in accordance with API Standard 660, TEMA (10th Edition), and ASME Section VIII Division 1.

$$Q = \dot{m}_{vap} \cdot h_{fg} = U_{dirty} \cdot A_{eff} \cdot \Delta T_{lm}$$
$$h_{nb} = 0.104 \cdot P_c^{0.69} \cdot (q'')^{0.7} \cdot \left[ 1.8 \cdot P_r^{0.17} + 4.0 \cdot P_r^{1.2} + 10.0 \cdot P_r^{10} \right] \quad \text{(Mostinski Nucleate Pool Boiling)}$$
$$q''_{crit,single} = 0.131 \cdot h_{fg} \cdot \sqrt{\rho_V} \cdot \left[ g \cdot \sigma \cdot (\rho_L - \rho_V) \right]^{0.25}, \quad q''_{max,bundle} = q''_{crit,single} \cdot \psi_b$$
$$u_{v,max} = K_{SB} \cdot \sqrt{\frac{\rho_L - \rho_V}{\rho_V}} \quad \text{(Souders-Brown Vapor Velocity)}, \quad h_{crest} = \left( \frac{\dot{V}_{liq}}{1.84 \cdot W_{weir}} \right)^{2/3}$$
$$\Delta P_{driving} = (\rho_L \cdot g \cdot H_{sump}) - (\bar{\rho}_{tp} \cdot g \cdot L_{tube}) \ge \sum \Delta P_{loop} \quad \text{(Thermosiphon Balance)}$$

2. Standard Parameters & API 660 / TEMA Design Criteria

Service / Reboiler Configuration Typical Overall U ($W/m^2\cdot K$) Recommended Design Limits & Acceptance Criteria
TEMA K Kettle (Light Hydrocarbon C3-C5) $1,000 - 1,600\text{ W/m}^2\cdot\text{K}$ $q'' \le 0.70 \cdot q''_{max,bundle}$; $D_s / D_b \ge 1.45$; $H_{dis} \ge 250\text{ mm}$; $50\text{ mm}$ weir submergence.
TEMA K Kettle (Gasoline / Naphtha Stabilizer) $750 - 1,200\text{ W/m}^2\cdot\text{K}$ Square pitch recommended for mechanical cleaning; $u_v \le u_{v,max}$ ($K_{SB} = 0.050\text{ m/s}$).
Vertical Thermosiphon (Amine Stripper / Water) $1,200 - 2,200\text{ W/m}^2\cdot\text{K}$ $X_{pass} = 15\% - 25\%$; Safety Factor $\Delta P_{static} / \Delta P_{loop} \ge 1.05$; $v_{down} = 1.0 - 2.0\text{ m/s}$.
Vertical Thermosiphon (Alcohol / Chemical) $1,000 - 1,800\text{ W/m}^2\cdot\text{K}$ Tube length $2.44 - 3.66\text{ m}$ (8-12 ft); column liquid level aligned with top tubesheet.
Critical Burnout Safety Margin Flux Ratio $\le 0.70$ Mandatory buffer against film boiling transition, vapor choking, and tube wall burnout.

3. Engineering Assumptions & Boundary Limits

  • Nucleate Boiling Dominance: Pool boiling model operates in the nucleate regime, verified against the Mostinski reduced pressure threshold.
  • Bundle Vapor Restriction: Accounts for rising vapor blankets reducing effective bundle critical heat flux via the Palen-Small geometric factor ($0.35 \le \psi_b \le 0.85$).
  • Souders-Brown Disengagement: Ensures vapor superficial velocity does not exceed the droplet entrainment threshold ($u_{v,max}$), preventing liquid carryover into column trays.
  • Thermosiphon Stability: Requires percent vaporization per pass between $10\%$ and $30\%$ to preclude dryout wall starvation and density-wave Chatoorgoon oscillations.

📚 ChemProCal Knowledge Base

Need Complete Mathematical Derivations & Industrial Case Studies? Explore our in-depth engineering textbook guide: Kettle & Thermosiphon Reboiler Sizing: API 660 & TEMA K-Shell Design Guide.

Read Full Theory Guide →
Peer Review & Engineering Accuracy

This specification sheet and its mathematical formulations adhere to internationally recognized process codes (API Standard 660, TEMA 10th Edition Section 5: Type K Reboilers, and ASME Section VIII Division 1). Sizing parameters and default design allowances are cross-referenced with empirical refinery distillation benchmarks.

📚 ChemProCal Knowledge Base

Need Complete Mathematical Derivations & Industrial Case Studies?

Explore our in-depth engineering textbook guide: Kettle & Thermosiphon Reboiler Sizing: API 660 & TEMA K-Shell Design Guide. Features step-by-step manual hand calculations, thermodynamic proofs, and commercial simulator benchmarks.

Read Full Theory Guide →
Peer Review & Engineering Accuracy

This specification sheet and its mathematical formulations adhere to internationally recognized process codes (ASME, API, GPSA, TEMA, and ISA). Sizing parameters and default design allowances are cross-referenced with empirical industry design practices.

About This Tool

Distillation Reboiler Rating: Nucleate Pool Boiling, TEMA K-Shell Disengagement & Thermosiphon Natural Circulation

Principles of Distillation Column Reboilers (API 660 / TEMA K)

Reboilers are specialized shell-and-tube heat exchangers designed to boil column bottoms liquid, generating the ascending vapor stream that strips volatile components up a distillation column. Operating at the highest temperature and pressure in the distillation column system, reboilers handle heavy, high-boiling residues and represent a major capital and energy investment.

Under API Standard 660 and TEMA Section 5, reboiler design requires simultaneous optimization of nucleate boiling heat transfer, tube bundle vapor escape geometry, and phase separation to avoid catastrophic operational pitfalls such as film boiling burnout, liquid droplet carryover, and natural circulation hydraulic stalling.

Nucleate Pool Boiling & Critical Heat Flux (CHF Burnout Limit)

Liquid boiling occurs across four distinct thermodynamic regimes: natural convection, nucleate boiling, transition boiling, and film boiling. Optimal process design requires operation strictly within the high-performance nucleate boiling regime, where vapor bubbles form at discrete microscopic surface cavities and detach rapidly, producing heat transfer coefficients reaching 1,500 to 5,000 W/m²·K.

However, if the operating heat flux exceeds the Critical Heat Flux ($q''_{max}$), vapor bubbles merge into a continuous vapor blanket covering the tubes. In film boiling, the thermal resistance skyrockets, causing heat transfer to collapse and tube wall temperatures to spike. Our engine evaluates the Mostinski and Kutateladze-Zuber critical heat flux and enforces API 660 safety rules ($q'' \le 0.70 \cdot q''_{max,bundle}$).

TEMA K-Shell Vapor Disengagement & Francis Weir Geometry

The TEMA Type K kettle reboiler features an eccentric enlarged shell surrounding a submerged horizontal tube bundle. The upper shell volume serves as a gravity disengagement space where liquid droplets fall out of the rising vapor stream before entering the column return nozzle.

The maximum permissible vapor velocity ($u_{v,max}$) is determined by the Souders-Brown correlation ($u_v = K_{SB} \sqrt{(\rho_L - \rho_V)/\rho_V}$). An internal overflow weir plate maintains a minimum 50 mm liquid cover over the bundle top, while liquid spilling over the weir collects in a downstream residue compartment sized for 1.5 to 3 minutes of residence time.

Vertical Thermosiphon Natural Circulation & Driving Head Balance

Unlike kettle reboilers, vertical thermosiphons operate via natural density-driven circulation without a mechanical pump. Cold, dense liquid in the column bottoms downcomer pipe ($\rho_L$) exerts hydrostatic pressure that pushes liquid into vertical tubes.

As the liquid ascends through the heated tubes, it flashes into a low-density two-phase vapor-liquid froth ($\bar{\rho}_{tp}$). The natural driving head ($\Delta P_{driving} = [\rho_L \cdot g \cdot H_{sump}] - [\bar{\rho}_{tp} \cdot g \cdot L_{tube}]$) balances total loop friction (inlet downcomer, tubes, acceleration, and return riser). Stable natural circulation requires a driving safety factor $\ge 1.05$.

Step-by-Step Worked Example: C3/C4 Depropanizer Kettle Reboiler

Scenario: Size a TEMA K-shell kettle reboiler boiling 25,000 kg/h of isobutane/n-butane at 16.0 bar ($T_{boil} = 110.0^\circ\text{C}$) using saturated steam at 4.5 barg ($T_{sat} = 155.0^\circ\text{C}$).

  1. Heat Duty ($Q$):
    $$Q = \frac{25,000 \times 295}{3600} = 2,048.6\text{ kW}$$
  2. Driving Temperature & Area Sizing:
    $$\Delta T_m = 155.0 - 110.0 = 45.0^\circ\text{C}$$
    Mostinski nucleate pool boiling yields $h_{nb} = 3,180\text{ W/m}^2\cdot\text{K}$, giving dirty overall coefficient $U_{dirty} = 1,180.6\text{ W/m}^2\cdot\text{K}$.
    Required surface area: $A_{req} = 38.56\text{ m}^2$. Selecting 102 U-tubes ($25.4\text{ mm}$ OD, $4.88\text{ m}$ length) gives $A_{installed} = 39.72\text{ m}^2$ ($+3.0\%$ margin).
  3. Critical Heat Flux Check:
    Bundle burnout limit: $q''_{max,bundle} = 92,842\text{ W/m}^2$.
    Operating flux: $q'' = 51,577\text{ W/m}^2$ (Flux ratio $= 0.556 \le 0.70$ • Compliant).
  4. Kettle Shell Diameter:
    Bundle diameter $D_b = 430\text{ mm}$. Sizing enlarged shell for Souders-Brown velocity ($u_{v,max} = 0.171\text{ m/s}$) yields $D_s = 850\text{ mm}$ ($D_s / D_b = 1.98$) with $365\text{ mm}$ vapor freeboard ($> 250\text{ mm}$).

Frequently Asked Questions

What is the primary difference between a Kettle Reboiler and a Thermosiphon Reboiler?

A TEMA Type K Kettle reboiler operates as an unforced pool boiling vessel: the tube bundle is submerged in liquid inside an enlarged shell, and boil-off vapor separates by gravity in an upper freeboard dome before returning to the column. In contrast, a Vertical Thermosiphon reboiler relies on natural circulation: dense column bottoms liquid in a downcomer pipe pushes liquid through vertical tubes, where it flashes into a two-phase froth that discharges back into the column via a return riser. Kettles offer superior operational flexibility and act as an extra theoretical distillation stage, whereas thermosiphons provide higher heat transfer coefficients, lower liquid residence times, and a smaller equipment footprint.

What is Critical Heat Flux (CHF) and why is it limited to 70% in design?

Critical Heat Flux (CHF or burnout limit) is the maximum heat flux achievable in nucleate boiling before vapor bubbles coalesce into a continuous vapor blanket covering the heating tubes. In film boiling, the thermal resistance increases tenfold, causing catastrophic loss of reboiling duty and severe tube metal overheating. API 660 and GPSA guidelines mandate that design heat flux must not exceed 70% of the tube bundle burnout limit (q''actual <= 0.70 * q''max,bundle) to ensure a safe operational margin against sudden flow or pressure disturbances.

How is the vapor space disengagement height sized in a TEMA K kettle shell?

The vapor space height (freeboard) is sized using the Souders-Brown superficial vapor velocity equation: u_v,max = K_sb * sqrt((rho_L - rho_V) / rho_V). Under API 660 and GPSA rules, the kettle shell diameter (Ds) must provide sufficient cross-sectional area so that the vapor velocity remains below u_v,max (typically K_sb = 0.050 m/s without demister, 0.100 m/s with mesh demister) and the vertical clearance between the weir liquid crest and the shell top is at least 250 mm (10 in) or 20% of the shell diameter.

Why is the percent vaporization per pass in a thermosiphon reboiler restricted to 10% to 30%?

If vaporization exceeds 30% per pass, the liquid film on the tube walls evaporates completely near the top tubesheet, causing annular mist dryout, heavy product thermal cracking, wall coking, and severe density-wave flow oscillations. Conversely, if vaporization is below 10%, the circulation rate is excessively high, causing steep loop friction losses that starve natural circulation and requiring oversized downcomer and riser piping.

What is the purpose of the liquid overflow weir in a kettle reboiler?

The overflow weir plate serves two vital functions: first, it maintains a constant liquid level ensuring the entire tube bundle remains permanently submerged under at least 50 mm of boiling liquid pool, preventing dryout of upper tube rows. Second, it creates an isolated downstream residue compartment where non-vaporized bottoms liquid overflows and collects, providing steady, surge-free suction head for bottoms product export pumps.

Related Engineering Tools

Tool Units

Input / Output Units

Configure global unit system preset or individual parameter dimensions.

CALCULATED RESULT