ChemProCal • Thermodynamics • TEG Dehydration Absorber & Regeneration Skid Sizer
THERMODYNAMICS

TEG Dehydration Absorber & Regeneration Skid Sizer

Size Triethylene Glycol (TEG) gas dehydration contactor diameter (Souders-Brown), lean glycol circulation rate, regeneration reboiler duty, and stripping gas demand per GPSA Chapter 20.



Gas Feed & Contactor Operating Conditions

MMSCFD
SG

Dehydration Specification & Regeneration Parameters

lb/MMSCF
gal/lb H2O
°C
ft/s

📐 Engineering Formula & Specification Sheet

TEG Dehydration Absorber & Regeneration Skid Sizer: Sizing Methodology & Engineering Basis

Size Triethylene Glycol (TEG) gas dehydration contactor diameter (Souders-Brown), lean glycol circulation rate, regeneration reboiler duty, and stripping gas demand per GPSA Chapter 20.

👨‍🔬 Reviewed by: Process Design Engineer (B.Tech Chemical Engineering, 5+ Yrs Exp)
🗓️ Standards: ASME / API / GPSA / ISA
⏱️ Format: Quick Reference Spec Sheet

1. GPSA Chapter 20 Water Dew Point Suppression

The required dry gas moisture specification is achieved by balancing counter-current glycol circulation with contactor vapor-liquid equilibrium:

\[ \Delta W = W_{in}(T, P) - W_{spec} \]

Where water content \(W\) is evaluated using the Bukacek correlation.

2. Souders-Brown Column Diameter

To prevent glycol droplet entrainment and foaming carryover, maximum allowable vapor velocity is constrained by the Souders-Brown equation:

\[ v_{max} = K_{SB} \sqrt{\frac{\rho_L - \rho_G}{\rho_G}} \qquad D_{col} = \sqrt{\frac{4 \cdot Q_{act}}{\pi \cdot v_{design}}} \]

3. Regeneration Skid Thermal Duty

Atmospheric reboiler heat input balances sensible preheating, latent water vaporization, and reflux duty:

\[ Q_{reb} = 1.10 \cdot \left[ \dot{m}_{rich} C_p (T_{reb} - T_{feed}) + 1.25 \cdot \dot{m}_{H_2O} \Delta H_{vap} \right] \]

📚 ChemProCal Knowledge Base

Need Complete Mathematical Derivations & Industrial Case Studies?

Explore our in-depth engineering textbook guide: Natural Gas Dehydration Technology Selection: TEG Absorption, Molecular Sieve Adsorption, Silica Gel & Supersonic Separators Guide. Features step-by-step manual hand calculations, thermodynamic proofs, and commercial simulator benchmarks.

Peer Review & Engineering Accuracy

This specification sheet and its mathematical formulations adhere to internationally recognized process codes (ASME, API, GPSA, TEMA, and ISA). Sizing parameters and default design allowances are cross-referenced with empirical industry design practices.

About This Tool

The TEG Dehydration Absorber & Regeneration Skid Sizer designs and evaluates natural gas dehydration units in strict adherence to GPSA Engineering Data Book Chapter 20, the Worley and Parrish-Wong liquid-vapor equilibrium models, and the Souders-Brown droplet entrainment hydrodynamic limits. It sizes the high-pressure absorption contactor column (bubble-cap trays or structured packing) and the complete atmospheric regeneration reboiler skid, including thermal duties, pump hydraulics, and stripping gas demand.

Raw natural gas emerging from production reservoirs is saturated with water vapor. If unmitigated, temperature and pressure drops during transmission induce clathrate hydrate crystallization, catastrophic line blockage, and acid-gas pipeline corrosion. Liquid desiccant absorption utilizing Triethylene Glycol (TEG) represents the worldwide benchmark for continuous high-capacity gas dehydration, providing exceptional hygroscopic affinity, high thermal decomposition thresholds (206°C), low vapor pressure losses, and high water dew point depressions exceeding 50°C.

1. Thermodynamic Principles of Glycol Absorption & Dew Point Suppression

Triethylene Glycol (\(\text{C}_6\text{H}_{14}\text{O}_4\), TEG) is the premier liquid desiccant for natural gas dehydration due to its high boiling point (285°C / 545°F), high thermal stability limit (206°C / 404°F), low vapor pressure at contactor temperatures, and superior hygroscopic affinity driven by hydrogen bonding between water molecules and ether-hydroxyl functional groups.

Water-TEG Vapor-Liquid Phase Equilibrium

In a counter-current contactor, dry lean TEG enters at the top tray while wet natural gas enters beneath the bottom tray. The equilibrium water vapor pressure above an aqueous TEG solution is governed by modified Raoult's law incorporating the liquid activity coefficient of water (\(\gamma_{w}\)):

\[ P_{w} = x_{w} \cdot \gamma_{w}(x_{w}, T) \cdot P_{w}^\circ(T) \]

Where \(x_w\) is the mole fraction of water in the liquid TEG phase, and \(P_w^\circ(T)\) is the saturation vapor pressure of pure water at contactor temperature. Because TEG and water form a highly non-ideal polar mixture, the activity coefficient \(\gamma_w\) is significantly less than unity at low water concentrations (\(\gamma_w \approx 0.3 - 0.5\)), enabling profound dew point suppression far below ideal liquid absorption limits.

Required Lean Glycol Concentration & Worley Curves

The contract water dew point depression (\(\Delta T_{dp}\)) is the difference between inlet gas temperature and the dry gas water dew point:

\[ \Delta T_{dp} = T_{inlet} - T_{dp,target} \]

Per GPSA Engineering Data Book Figure 20-53 and the Worley correlation, the required lean TEG purity entering the top of the contactor is directly determined by the target dew point depression. Standard atmospheric reboilers without stripping gas achieve 98.5 to 99.0 wt% TEG, providing a maximum dew point depression of approximately 35°C to 40°C (65°F to 75°F). To achieve cryogenic pipeline specifications (< 4 lb/MMSCF) or Arctic delivery conditions requiring depressions of 50°C to 70°C, lean TEG purity must reach 99.5 to 99.95 wt%, necessitating stripping gas or vacuum regeneration.

2. Contactor Column Hydrodynamics & Souders-Brown Sizing

The gas contactor column provides intimate interfacial contact between the downward-flowing viscous TEG liquid and the upward-flowing high-pressure gas. Contactors are fabricated either with bubble-cap trays (traditional, robust against fouling) or structured packing (e.g., Mellapak, featuring lower pressure drops and reduced column diameter).

Souders-Brown Maximum Vapor Velocity

To prevent gas bubbling from carrying liquid glycol droplets upward out of the contactor (entrainment flooding), the superficial gas velocity must not exceed the terminal settling velocity derived from momentum balance and droplet drag, formalized by the Souders-Brown equation:

\[ v_{max} = K_{SB} \sqrt{\frac{\rho_L - \rho_G}{\rho_G}} \]

Where \(\rho_L\) is the liquid TEG density (\(\approx 1100 \text{ kg/m}^3\)), \(\rho_G\) is the in-situ gas density at operating pressure and temperature, and \(K_{SB}\) is the empirical Souders-Brown design factor:

  • Bubble-Cap Trays (24-inch tray spacing): \(K_{SB} = 0.16 \text{ to } 0.18 \text{ ft/s } (0.049 \text{ to } 0.055 \text{ m/s})\).
  • Structured Packing: \(K_{SB} = 0.20 \text{ to } 0.25 \text{ ft/s } (0.061 \text{ to } 0.076 \text{ m/s})\).

To maintain operational stability, avoid foaming entrainment, and handle feed rate surges, the conservative design operating velocity is set to 70% to 75% of maximum Souders-Brown velocity (\(v_{design} = 0.70 \cdot v_{max}\)).

Column Diameter & Height Sizing

The cross-sectional area and internal diameter of the contactor column are sized from actual flowing volumetric gas rate (\(Q_{act}\)):

\[ A_{col} = \frac{Q_{act}}{v_{design}} \qquad D_{col} = \sqrt{\frac{4 \cdot A_{col}}{\pi}} \]

Contactor internal diameter is rounded up to standard vessel fabrications (e.g., 24", 30", 36", 42", 48", 54", 60"). The column typically houses 6 to 8 bubble-cap trays (or 3 to 4.5 meters of structured packing, with HETP \(\approx 0.5 \text{ m}\)), delivering 1.5 to 2.5 theoretical equilibrium stages required for commercial dehydration.

3. Regeneration Skid Energetics, Reboiler Heat Balance & Stripping Gas Demand

The regeneration skid desorbs the absorbed water from the rich TEG stream to restore high lean purity for continuous reinjection into the contactor. The regeneration assembly consists of a flash separator (removes dissolved methane at 4-5 barg), particulate and activated carbon filters, a lean/rich glycol heat exchanger, a distillation still column with reflux condenser, and an atmospheric reboiler.

Thermal Decomposition Threshold & Operating Temperatures

Triethylene Glycol undergoes thermal degradation into corrosive organic acids and heavy oligomers at 206°C (404°F). Therefore, reboiler firetube or electric heating elements are strictly controlled at an operating bulk liquid temperature of 200°C to 204°C (392°F to 400°F) with maximum firetube heat flux limited to \(8,000 \text{ to } 10,000 \text{ BTU}/(\text{hr}\cdot\text{ft}^2)\) to prevent localized skin skin-film overheating.

Reboiler Thermal Duty Heat Balance

The total heat input required by the reboiler encompasses sensible liquid heating, endothermic latent heat of water vaporization, reflux condenser cooling load, and ambient insulation losses:

\[ Q_{reb} = 1.10 \cdot \left[ Q_{sensible} + Q_{latent} + Q_{reflux} \right] \]

  • Sensible Heating: \(Q_{sens} = \dot{m}_{rich} \cdot C_{p,TEG} \cdot (T_{reb} - T_{feed})\), where rich glycol preheated in the lean/rich exchanger enters at \(\approx 150°\text{C}\) and \(C_p \approx 2.75 \text{ kJ}/(\text{kg}\cdot\text{K})\).
  • Water Latent Heat: \(Q_{latent} = \dot{m}_{H_2O} \cdot \Delta H_{vap}\), with \(\Delta H_{vap} \approx 2260 \text{ kJ/kg}\).
  • Reflux & Desolvation Allowance: \(\approx 25\%\) of latent vaporization duty to condense reflux in the still column top and prevent vaporized TEG loss.
  • Heat Losses: 10% safety margin added for surface radiation and convection losses.

Stripping Gas Sizing for High Purity (>99.5 wt%)

Under atmospheric boiling at 204°C, the equilibrium concentration of TEG is constrained by Dalton's law of partial pressures to 98.7 wt%. To drive purity above 99.5 to 99.9 wt%, superheated dry stripping gas (fuel gas or sales gas) is sparged through a packed stripping column located between the reboiler and the surge accumulator. The stripping gas lowers the water vapor partial pressure according to:

\[ y_{w} = \frac{P_{w,eq}}{P_{total}} \]

GPSA design guidelines prescribe 2.0 to 8.0 scf of stripping gas per gallon of TEG circulated (\(0.015 \text{ to } 0.06 \text{ Sm}^3/\text{L}\)), reducing equilibrium water vapor partial pressure and stripping residual moisture down to 0.05 wt%.

Frequently Asked Questions

What is the maximum allowable reboiler temperature for Triethylene Glycol (TEG) and why?
The maximum allowable bulk liquid temperature in a TEG reboiler is strictly 204°C (400°F). Triethylene Glycol begins rapid, irreversible thermal decomposition at 206°C (404°F). Thermal cracking cleaves the glycol ether linkages, producing corrosive low-molecular-weight organic acids (such as formic, acetic, and glycolic acids) as well as heavy dark oligomers and carbonaceous sludge. This causes the circulating glycol pH to drop below 6.0, accelerating acidic corrosion of contactor internals, fouling heat exchanger tubes, and severely reducing desiccant absorption capacity.
How do I choose between bubble-cap trays and structured packing in a TEG contactor?
The selection between bubble-cap trays and structured packing depends on gas throughput, fouling potential, and weight/footprint constraints:
  • Bubble-Cap Trays: The traditional industry benchmark (typically 6 to 8 trays at 24-inch spacing). Bubble-cap trays maintain a positive liquid seal across all flow rates, providing excellent turndown ratio (down to 20% of design capacity) and superior resistance to fouling from dirty feed gas, compressor lube oils, and particulate matter.
  • Structured Packing: Offers 30% to 50% greater gas capacity per unit diameter, allowing significantly smaller, lighter vessels (critical for offshore platforms). Packing exhibits very low pressure drop (often < 0.2 psi per bed) but is vulnerable to liquid maldistribution, fouling from iron sulfide, and foaming if heavy hydrocarbons condense in the contactor.
When is stripping gas required in a TEG dehydration unit?
Stripping gas is required whenever the required dry gas water dew point depression exceeds 38°C to 42°C (70°F to 75°F), or whenever lean TEG purity must exceed 99.1 wt%. Atmospheric boiling at 204°C inherently reaches an equilibrium limit of approximately 98.7 to 99.0 wt% TEG due to atmospheric water partial pressure. If contract specifications require water content below 4.0 lb/MMSCF (64 mg/Sm³) or cryogenic feed preparation (< 1.0 lb/MMSCF for turbo-expander NGL extraction), dry stripping gas (2 to 8 scf/gal TEG) or a Coldfinger condensation system must be deployed.
What causes glycol foaming and how is it mitigated in plant operations?
Glycol foaming is the primary operational cause of severe contactor carryover, massive glycol chemical losses, and off-spec wet sales gas. Foaming occurs when liquid surface tension is altered by contaminants:
  1. Condensed Liquid Hydrocarbons: Occurs when inlet gas drops below its hydrocarbon dew point in the contactor. Lean glycol must always enter the contactor 3°C to 5°C (5°F to 10°F) warmer than the inlet gas to prevent hydrocarbon condensation.
  2. Corrosion Inhibitors & Well Treating Chemicals: Upstream filming amines carry over into the gas stream.
  3. Fine Particulates: Iron sulfide (FeS) and scale stabilize froth.
Mitigation requires efficient inlet filter-coalescers, regular maintenance of the activated carbon filter (which adsorbs dissolved hydrocarbons and surfactants), and continuous monitoring of glycol pH (maintained at 7.0 to 8.5 using triethanolamine or borax buffer).