The gas contactor column provides intimate interfacial contact between the downward-flowing viscous TEG liquid and the upward-flowing high-pressure gas. Contactors are fabricated either with bubble-cap trays (traditional, robust against fouling) or structured packing (e.g., Mellapak, featuring lower pressure drops and reduced column diameter).
Souders-Brown Maximum Vapor Velocity
To prevent gas bubbling from carrying liquid glycol droplets upward out of the contactor (entrainment flooding), the superficial gas velocity must not exceed the terminal settling velocity derived from momentum balance and droplet drag, formalized by the Souders-Brown equation:
\[ v_{max} = K_{SB} \sqrt{\frac{\rho_L - \rho_G}{\rho_G}} \]
Where \(\rho_L\) is the liquid TEG density (\(\approx 1100 \text{ kg/m}^3\)), \(\rho_G\) is the in-situ gas density at operating pressure and temperature, and \(K_{SB}\) is the empirical Souders-Brown design factor:
- Bubble-Cap Trays (24-inch tray spacing): \(K_{SB} = 0.16 \text{ to } 0.18 \text{ ft/s } (0.049 \text{ to } 0.055 \text{ m/s})\).
- Structured Packing: \(K_{SB} = 0.20 \text{ to } 0.25 \text{ ft/s } (0.061 \text{ to } 0.076 \text{ m/s})\).
To maintain operational stability, avoid foaming entrainment, and handle feed rate surges, the conservative design operating velocity is set to 70% to 75% of maximum Souders-Brown velocity (\(v_{design} = 0.70 \cdot v_{max}\)).
Column Diameter & Height Sizing
The cross-sectional area and internal diameter of the contactor column are sized from actual flowing volumetric gas rate (\(Q_{act}\)):
\[ A_{col} = \frac{Q_{act}}{v_{design}} \qquad D_{col} = \sqrt{\frac{4 \cdot A_{col}}{\pi}} \]
Contactor internal diameter is rounded up to standard vessel fabrications (e.g., 24", 30", 36", 42", 48", 54", 60"). The column typically houses 6 to 8 bubble-cap trays (or 3 to 4.5 meters of structured packing, with HETP \(\approx 0.5 \text{ m}\)), delivering 1.5 to 2.5 theoretical equilibrium stages required for commercial dehydration.