1. Theoretical Foundations & Engineering Mechanics
Unsteady-State Accumulation
When mass flows in and out of a process vessel are unbalanced, or when inlet stream concentrations fluctuate with time, the accumulation term in the conservation equation cannot be neglected:
$$\frac{dM_{total}}{dt} = \sum_{in} \dot{m}_{in}(t) - \sum_{out} \dot{m}_{out}(t)$$
$$\frac{d(M x_i)}{dt} = \sum_{in} (w_i \dot{m})_{in} - \sum_{out} (w_i \dot{m})_{out}$$
Expanding the derivative of the product $M x_i$ via the chain rule:
$$\frac{d(M x_i)}{dt} = M \frac{dx_i}{dt} + x_i \frac{dM}{dt}$$
Two Canonical Industrial Archetypes
- Constant Volume Tank with Variable Concentration (Stirred Flush / Dilution):
If inflow equals outflow ($Q_{in} = Q_{out} = Q$), liquid volume $V$ is constant ($dM/dt = 0$):
$$V \frac{dC}{dt} = Q C_{in} - Q C \implies \tau \frac{dC}{dt} + C = C_{in}, \quad \tau = \frac{V}{Q}$$
Solving for a step from initial concentration $C_0$ to pure flush water ($C_{in} = 0$):
$$C(t) = C_0 e^{-t/\tau}$$ - Gravity Tank Drainage (Torricelli's Law):
Discharge flow rate varies with instantaneous liquid level $h(t)$:
$$Q_{out}(t) = C_d A_{orifice} \sqrt{2 g h(t)}$$
$$A_{tank} \frac{dh}{dt} = -C_d A_{orifice} \sqrt{2 g h(t)}$$
Separating variables and integrating yields the total drain time.
2. Governing Equations & Mathematical Formulation
$$\frac{dM}{dt} = \dot{m}_{in} - \dot{m}_{out}$$
$$\frac{d(V C)}{dt} = Q_{in} C_{in} - Q_{out} C_{out}$$
$$C(t) = C_{in} + (C_0 - C_{in}) e^{-t/\tau}$$
$$t_{drain} = \frac{2 A_{tank}}{C_d A_o \sqrt{2g}} \left( \sqrt{h_0} - \sqrt{h_f} \right)$$
• Fluid density is constant ($1000\text{ kg/m}^3$).
• Liquid volume remains exactly constant at $8.0\text{ m}^3$.
• Complete backmixing without stagnant dead zones.
• Fresh water feed contains zero salt.
• Forgetting exponential decay formula.
• Confusing flushing percentage ($99\%$) with remaining fraction ($1\%$).
• Dividing volume by tank area instead of volumetric flow rate when computing time constant.
3. Applied Engineering Worked Example
Standard process engineering operating and design conditions.
Step-by-Step Analytical Solution:
-
Governing differential equation:
$$V \frac{dC}{dt} = Q_{in} C_{in} - Q_{out} C(t)$$
Since $C_{in} = 0$ and $Q_{in} = Q_{out} = Q$:
$$V \frac{dC}{dt} = -Q C(t) \implies \frac{dC}{dt} + \frac{Q}{V} C(t) = 0$$
$$\frac{dC}{C} = -\frac{Q}{V} dt$$
Integrating from $C_0$ to $C(t)$:
$$C(t) = C_0 e^{-(Q/V) t} = C_0 e^{-t/\tau}$$ -
Time constant $\tau$:
$$\tau = \frac{V}{Q} = \frac{8.00\text{ m}^3}{0.40\text{ m}^3/\text{min}} = \mathbf{20.00\text{ min}}$$ -
Concentration at $t = 30.0\text{ min}$:
$$C(30.0) = 50.0 \times e^{-30.0 / 20.0} = 50.0 \times e^{-1.50} = 50.0 \times 0.22313 = \mathbf{11.16\text{ kg/m}^3}$$ -
Time to remove 99.0% of salt:
To remove $99.0\%$, the remaining concentration is $1.0\%$ of $C_0$:
$$C(t) = (0.010)(50.0) = 0.50\text{ kg/m}^3$$
$$0.010 = e^{-t / 20.0} \implies -\frac{t}{20.0} = \ln(0.010) = -4.60517$$
$$t = 20.00 \times 4.60517 = \mathbf{92.10\text{ min}}$$
Flushing $99\%$ of inventory requires $4.6$ residence times ($92.1\text{ min}$).