Single Unit Non-Reactive Balances (Mixers, Separators)
Covers steady-state material balances on single unit operations without chemical reactions, detailing component balances, basis selection rules, stream splitting, and flash separator calculations.
1. Theoretical Foundations & Engineering Mechanics
Steady-State Conservation of Mass
In non-reactive systems at steady state, accumulation equals zero ($dM/dt = 0$), and no chemical generation or consumption takes place. The conservation law for total mass and each individual chemical component $i$ across a single control volume simplifies to:
$$\sum_{in} \dot{m}_{in} = \sum_{out} \dot{m}_{out}$$
$$\sum_{in} (w_{i} \dot{m})_{in} = \sum_{out} (w_{i} \dot{m})_{out}$$
For a system containing $C$ non-reacting chemical species, exactly $C$ independent material balance equations can be formulated. The total mass balance is simply the linear sum of all $C$ component balances.
Systematic Solution Methodology
- Flowsheet Diagram & Control Volume: Draw a clear boundary enclosing the unit operation and label all entering and exiting streams with flow rates and mass or mole fractions.
- Selection of Basis: If no absolute stream flow rate is given, select a convenient basis (e.g., $100\text{ kg/h}$ or $100\text{ kmol/h}$ of feed).
- Degree of Freedom Audit: Verify $N_{DF} = 0$ before commencing calculations.
- Sequential Equation Ordering: Identify component balances containing only a single unknown to solve sequentially, avoiding unnecessary matrix inversion.
2. Governing Equations & Mathematical Formulation
$$\sum \dot{m}_{in} = \sum \dot{m}_{out}$$
$$\sum (w_{i} \dot{m})_{in} = \sum (w_{i} \dot{m})_{out}$$
$$\sum_{i=1}^C w_i = 1.0$$
$$N_{independent} = C$$
• Process operates in a time-invariant steady state ($dM/dt = 0$).
• No chemical reactions occur between species.
• Mass is strictly conserved (nuclear mass-energy conversion is zero).
• Entrainment and wall losses are negligible.
• Changing basis mid-calculation without rescaling previously derived stream rates.
• Attempting to write $C+1$ independent equations for a $C$-component system.
• Using volumetric flow rates directly in balance equations without multiplying by density (volume is NOT conserved upon mixing).
• Mixing mass fractions and mole fractions in the same algebraic equation.
3. Applied Engineering Worked Example
An evaporative concentrator treats a dilute sugar solution to produce concentrated syrup. Feed enters at $\dot{m}_F = 5000.0\text{ kg/h}$ containing $12.0\text{ wt%}$ dissolved sugar and $88.0\text{ wt%}$ water. The evaporator produces concentrated syrup containing $65.0\text{ wt%}$ sugar and pure water vapor overhead.
- Draw the control volume and specify knowns and unknowns.
- Write the sugar component mass balance and determine the product syrup production rate $\dot{m}_S$ [kg/h].
- Write the overall mass balance and calculate the water evaporation rate $\dot{m}_V$ [kg/h].
- Calculate the percentage of water present in the feed that was evaporated.
Step-by-Step Analytical Solution:
-
Variables and specifications:
- Feed: $\dot{m}_F = 5000.0\text{ kg/h}$, $w_{sugar,F} = 0.120, w_{water,F} = 0.880$
- Syrup: $\dot{m}_S = ?$, $w_{sugar,S} = 0.650, w_{water,S} = 0.350$
- Vapor: $\dot{m}_V = ?$, $w_{sugar,V} = 0.000, w_{water,V} = 1.000$ -
Sugar component balance:
$$w_{sugar,F} \dot{m}_F = w_{sugar,S} \dot{m}_S + w_{sugar,V} \dot{m}_V$$
$$(0.120)(5000.0) = (0.650) \dot{m}_S + 0$$
$$600.0 = 0.650 \dot{m}_S \implies \dot{m}_S = \frac{600.0}{0.650} = \mathbf{923.08\text{ kg/h}}$$ -
Overall mass balance:
$$\dot{m}_F = \dot{m}_S + \dot{m}_V$$
$$\dot{m}_V = 5000.0 - 923.08 = \mathbf{4076.92\text{ kg/h}}$$ -
Water removal percentage:
- Water in feed: $(5000.0)(0.880) = 4400.0\text{ kg/h}$
- Water evaporated: $4076.92\text{ kg/h}$
$$\%\text{ Water Evaporated} = \frac{4076.92}{4400.0} \times 100\% = \mathbf{92.66\%}$$
Interactive Practice Drill: Single Unit Non-Reactive Balances (Mixers, Separators)
Completed this lesson?
Record your study progress, build your daily streak, and unlock +25 XP toward your next engineering tier.
Connected ChemProCal Tool
Thermodynamic flash calculation and drum sizing.