Triethylene Glycol (TEG) Absorption & Water Dew Point Depression
Triethylene glycol (TEG) absorption chemistry, water dew point depression, circulation rates (gal TEG / lb H2O removed), and lean glycol concentration.
1. Theoretical Foundations & Engineering Mechanics
TEG Dehydration & Water Dew Point Depression
Natural gas produced from reservoirs is saturated with water vapor. If unremoved, cooling during pipeline transit forms solid gas hydrates (crystalline clathrates that choke lines) and creates corrosive carbonic acid ($H_2CO_3$).
1. Glycol Absorption Mechanism
Triethylene Glycol (TEG, $C_6H_{14}O_4$) is the universal liquid desiccant for natural gas dehydration because of its high hygroscopicity, low vapor pressure ($0.001\text{ mmHg}$ at $20^\circ\text{C}$), high thermal decomposition temperature ($206^\circ\text{C}$), and low solubility in hydrocarbons.
2. Lean Glycol Concentration & Equilibrium Dew Point
The water dew point achievable at the contactor outlet is fundamentally constrained by thermodynamic equilibrium with the incoming lean TEG:
- $99.0\text{ wt}\%$ Lean TEG: Achieves water dew point depression of $\sim 35 - 40^\circ\text{C}$ ($65 - 75^\circ\text{F}$).
- $99.5\text{ wt}\%$ Lean TEG: Achieves depression of $\sim 50 - 55^\circ\text{C}$ ($90 - 100^\circ\text{F}$).
- $99.9\text{ wt}\%$ Lean TEG (Stripping Gas): Achieves depression $> 70^\circ\text{C}$ ($> 125^\circ\text{F}$), meeting pipeline export specs (typically $< 4\text{ to } 7\text{ lb H}_2\text{O/MMSCF}$ or $-10^\circ\text{C}$ dew point).
3. Circulation Rate ($L/G$)
Per GPSA Engineering Data Book, standard TEG circulation rate is:
$$\text{Circulation Ratio} = 2.5 \text{ to } 4.0\text{ gal TEG per lb H}_2\text{O removed} \quad [20 - 35\text{ L TEG per kg H}_2\text{O}]$$
Operating below $2.0\text{ gal/lb}$ causes incomplete mass transfer; operating above $5.0\text{ gal/lb}$ wastes reboiler fuel gas and increases hydrocarbon emissions.
2. Governing Equations & Mathematical Formulation
$$\dot{m}_{H2O\_rem} = Q_g \times (W_{in} - W_{out}) \quad [\text{lb/h or kg/h}]$$
$$L_{TEG\_gpm} = \frac{\dot{m}_{H2O\_rem} \times (\text{gal/lb})}{60}$$
$$\text{Rich Glycol Purity: } x_{rich} = \frac{\dot{m}_{TEG,dry}}{\dot{m}_{TEG,dry} + \dot{m}_{H2O\_in\_glycol}} \approx 94 - 96\text{ wt}\%$$
$$\text{Dew Point Depression: } \Delta T_{dew} = T_{gas,inlet} - T_{water\_dewpoint,outlet}$$
• Natural gas enters contactor saturated with water at operating temperature and pressure.
• Contactor operates with structured packing or bubble cap trays (typically 1.5 to 3.0 theoretical stages).
• Lean glycol enters contactor $3$ to $5^\circ\text{C}$ warmer than inlet gas to prevent hydrocarbon condensation.
• Introducing lean glycol cooler than inlet gas, causing heavy hydrocarbons to condense into the glycol, triggering catastrophic contactor foaming.
• Over-circulating glycol, which overloads the reboiler duty and strips massive BTEX quantities into the regenerator overhead vent.
• Failing to install an inlet gas coalescing filter-separator ahead of the contactor.
3. Applied Engineering Worked Example
Gas Plant Capacity: $Q_g = 50\text{ MMSCFD}$ at $P = 65.0\text{ barg}$, $T = 38^\circ\text{C}$ ($100^\circ\text{F}$)
Inlet Gas Water Content: $W_{in} = 62.0\text{ lb H}_2\text{O/MMSCF}$
Sales Gas Water Spec: $W_{out} = 4.0\text{ lb H}_2\text{O/MMSCF}$
Design Circulation Rate: $3.0\text{ gal TEG / lb H}_2\text{O removed}$
-
Compute Total Water Removal Rate:
$$\Delta W = 62.0 - 4.0 = 58.0\text{ lb H}_2\text{O/MMSCF}$$
$$W_{H2O\_total} = 50\text{ MMSCFD} \times 58.0\text{ lb/MMSCF} = 2,900\text{ lb H}_2\text{O/day} = 120.83\text{ lb/h}$$
In metric: $120.83 / 2.2046 = 54.81\text{ kg/h}$. -
Compute Required TEG Circulation Rate:
$$L_{gpm} = \frac{120.83\text{ lb/h} \times 3.0\text{ gal/lb}}{60\text{ min/h}} = \frac{362.5}{60} = 6.042\text{ gpm}$$
In cubic meters per hour: $6.042 \times 0.2271 = 1.372\text{ m}^3/\text{h}$. -
Verify Rich Glycol Concentration:
Assuming $99.5\text{ wt}\%$ lean TEG (density $1120\text{ kg/m}^3$):
Pure TEG circulated $= 1.372 \times 1120 \times 0.995 = 1,529\text{ kg/h}$.
Rich TEG purity $= \frac{1529}{1529 + 54.81} = \frac{1529}{1583.8} = 96.54\text{ wt}\%$. (Well within normal $94 - 96.5\%$ limits).