ChemProCal Academy ChemProCal Academy Academy
🔥 1d Streak
⚡ 0 XP
⚙ + Open Calculator Login Sign Up
Learn / Separations & Gas Processing / Natural Gas Dehydration (TEG & Mol Sieve)
Natural Gas Dehydration (TEG & Mol Sieve) 3 Practice Questions ⚡ Live Calculator Connected

Triethylene Glycol (TEG) Absorption & Water Dew Point Depression

Triethylene glycol (TEG) absorption chemistry, water dew point depression, circulation rates (gal TEG / lb H2O removed), and lean glycol concentration.

⚡ Open Live Tool Practice Questions ↓

1. Theoretical Foundations & Engineering Mechanics

TEG Dehydration & Water Dew Point Depression

Natural gas produced from reservoirs is saturated with water vapor. If unremoved, cooling during pipeline transit forms solid gas hydrates (crystalline clathrates that choke lines) and creates corrosive carbonic acid ($H_2CO_3$).

1. Glycol Absorption Mechanism

Triethylene Glycol (TEG, $C_6H_{14}O_4$) is the universal liquid desiccant for natural gas dehydration because of its high hygroscopicity, low vapor pressure ($0.001\text{ mmHg}$ at $20^\circ\text{C}$), high thermal decomposition temperature ($206^\circ\text{C}$), and low solubility in hydrocarbons.

2. Lean Glycol Concentration & Equilibrium Dew Point

The water dew point achievable at the contactor outlet is fundamentally constrained by thermodynamic equilibrium with the incoming lean TEG:
- $99.0\text{ wt}\%$ Lean TEG: Achieves water dew point depression of $\sim 35 - 40^\circ\text{C}$ ($65 - 75^\circ\text{F}$).
- $99.5\text{ wt}\%$ Lean TEG: Achieves depression of $\sim 50 - 55^\circ\text{C}$ ($90 - 100^\circ\text{F}$).
- $99.9\text{ wt}\%$ Lean TEG (Stripping Gas): Achieves depression $> 70^\circ\text{C}$ ($> 125^\circ\text{F}$), meeting pipeline export specs (typically $< 4\text{ to } 7\text{ lb H}_2\text{O/MMSCF}$ or $-10^\circ\text{C}$ dew point).

3. Circulation Rate ($L/G$)

Per GPSA Engineering Data Book, standard TEG circulation rate is:
$$\text{Circulation Ratio} = 2.5 \text{ to } 4.0\text{ gal TEG per lb H}_2\text{O removed} \quad [20 - 35\text{ L TEG per kg H}_2\text{O}]$$
Operating below $2.0\text{ gal/lb}$ causes incomplete mass transfer; operating above $5.0\text{ gal/lb}$ wastes reboiler fuel gas and increases hydrocarbon emissions.

2. Governing Equations & Mathematical Formulation

$$\dot{m}_{H2O\_rem} = Q_g \times (W_{in} - W_{out}) \quad [\text{lb/h or kg/h}]$$

$$L_{TEG\_gpm} = \frac{\dot{m}_{H2O\_rem} \times (\text{gal/lb})}{60}$$

$$\text{Rich Glycol Purity: } x_{rich} = \frac{\dot{m}_{TEG,dry}}{\dot{m}_{TEG,dry} + \dot{m}_{H2O\_in\_glycol}} \approx 94 - 96\text{ wt}\%$$

$$\text{Dew Point Depression: } \Delta T_{dew} = T_{gas,inlet} - T_{water\_dewpoint,outlet}$$

💡 Formulated according to international process engineering standards and dimensionless groups.
📌 Key Engineering Assumptions

• Natural gas enters contactor saturated with water at operating temperature and pressure.
• Contactor operates with structured packing or bubble cap trays (typically 1.5 to 3.0 theoretical stages).
• Lean glycol enters contactor $3$ to $5^\circ\text{C}$ warmer than inlet gas to prevent hydrocarbon condensation.

⚠️ Common Industrial Pitfalls

• Introducing lean glycol cooler than inlet gas, causing heavy hydrocarbons to condense into the glycol, triggering catastrophic contactor foaming.
• Over-circulating glycol, which overloads the reboiler duty and strips massive BTEX quantities into the regenerator overhead vent.
• Failing to install an inlet gas coalescing filter-separator ahead of the contactor.

3. Applied Engineering Worked Example

Design Problem Specification

Gas Plant Capacity: $Q_g = 50\text{ MMSCFD}$ at $P = 65.0\text{ barg}$, $T = 38^\circ\text{C}$ ($100^\circ\text{F}$)
Inlet Gas Water Content: $W_{in} = 62.0\text{ lb H}_2\text{O/MMSCF}$
Sales Gas Water Spec: $W_{out} = 4.0\text{ lb H}_2\text{O/MMSCF}$
Design Circulation Rate: $3.0\text{ gal TEG / lb H}_2\text{O removed}$

Step-by-Step Mathematical Derivation & Verification
  1. Compute Total Water Removal Rate:
    $$\Delta W = 62.0 - 4.0 = 58.0\text{ lb H}_2\text{O/MMSCF}$$
    $$W_{H2O\_total} = 50\text{ MMSCFD} \times 58.0\text{ lb/MMSCF} = 2,900\text{ lb H}_2\text{O/day} = 120.83\text{ lb/h}$$
    In metric: $120.83 / 2.2046 = 54.81\text{ kg/h}$.

  2. Compute Required TEG Circulation Rate:
    $$L_{gpm} = \frac{120.83\text{ lb/h} \times 3.0\text{ gal/lb}}{60\text{ min/h}} = \frac{362.5}{60} = 6.042\text{ gpm}$$
    In cubic meters per hour: $6.042 \times 0.2271 = 1.372\text{ m}^3/\text{h}$.

  3. Verify Rich Glycol Concentration:
    Assuming $99.5\text{ wt}\%$ lean TEG (density $1120\text{ kg/m}^3$):
    Pure TEG circulated $= 1.372 \times 1120 \times 0.995 = 1,529\text{ kg/h}$.
    Rich TEG purity $= \frac{1529}{1529 + 54.81} = \frac{1529}{1583.8} = 96.54\text{ wt}\%$. (Well within normal $94 - 96.5\%$ limits).

Interactive Practice Drill: Triethylene Glycol (TEG) Absorption & Water Dew Point Depression

Instant answer checking, step rationales, and tolerance scoring.
Question 1 of 3
Loading interactive questions...

Completed this lesson?

Record your study progress, build your daily streak, and unlock +25 XP toward your next engineering tier.

⚡

Connected ChemProCal Tool

Run numerical simulations with real physical property packages.
TEG Dehydration Absorber & Regeneration Skid Sizer

Size Triethylene Glycol (TEG) gas dehydration contactor diameter (Souders-Brown), lean glycol circulation rate, regeneration reboiler duty, …

Verified Equations Engineering Tolerances
Launch Live Tool ⚡