TEG Circulation Rate (L/G), Equilibrium Dew Point & Tray/Packing Sizing
Kremser equation for TEG absorption, calculating number of equilibrium stages (NTS), tray efficiency, structured packing height, and flooding limits.
1. Theoretical Foundations & Engineering Mechanics
TEG Column Mass Transfer & Packing Sizing
The counter-current gas dehydration contactor uses either bubble cap trays or structured packing to facilitate mass transfer between rising wet gas and falling lean TEG.
1. The Kremser Equation for Absorption
The number of theoretical equilibrium stages $N$ required to achieve specified water removal is modeled by the Kremser-Brown-Souders equation:
$$N = \frac{\ln\left[ \left( \frac{y_{in} - m x_{in}}{y_{out} - m x_{in}} \right) \left(1 - \frac{1}{A}\right) + \frac{1}{A} \right]}{\ln(A)}$$
where:
- $A = L / (m G)$ is the dimensionless Absorption Factor (typically $A = 1.2$ to $2.0$ for optimal design)
- $L$: Molar liquid TEG circulation rate
- $G$: Molar gas flow rate
- $m$: Slope of water-TEG vapor-liquid equilibrium curve ($y^* = m x$)
- $y_{in}, y_{out}$: Water mole fractions in gas
- $x_{in}$: Water mole fraction in incoming lean TEG
2. Trays vs Structured Packing
- Bubble Cap Trays: Traditional standard (typically $6$ to $10$ actual trays on $24"$ spacing). Overall tray efficiency $E_o \approx 25\%$ to $35\%$ due to high glycol viscosity. Disadvantages: high pressure drop, larger column height.
- Structured Packing: Modern EPC standard (Mellapak 250X/250Y). Height Equivalent to a Theoretical Plate ($HETP \approx 1.2$ to $1.5\text{ m}$). Achieves identical mass transfer in a column $40\%$ shorter with $80\%$ lower pressure drop.
2. Governing Equations & Mathematical Formulation
$$A = \frac{L}{m \cdot G} \ge 1.20$$
$$Z_{packing} = N_{theoretical} \times HETP \quad [HETP \approx 1.2 - 1.5\text{ m for TEG}]$$
$$N_{actual\_trays} = \frac{N_{theoretical}}{E_o} \quad [E_o \approx 0.25 - 0.35]$$
$$v_{gas} \le 0.80 \times v_{flood} \approx 0.80 \times C_{sb} \left(\frac{\sigma}{20}\right)^{0.2} \sqrt{\frac{\rho_l - \rho_g}{\rho_g}}$$
• Isothermal absorption column operation (temperature rise from heat of absorption is typically $< 3 - 5^\circ\text{C}$).
• Gas velocity kept below 80% of flooding point.
• High-performance liquid distributors with $> 100\text{ drip points/m}^2$ required for structured packing.
• Using valve trays or sieve trays instead of bubble cap trays; at low gas rates, glycol dumps through perforations (weeping).
• Poor liquid distributor leveling, causing severe glycol channeling down one wall while gas bypasses untreated.
• Neglecting packing hold-down grids: sudden gas pressure surges lift structured packing blocks out of position.
3. Applied Engineering Worked Example
Dehydration Duty: Kremser calculation indicates $N_{theor} = 2.2$ theoretical stages
Packing Selected: Mellapak 250Y Structured Packing ($HETP = 1.35\text{ m}$)
Gas Volumetric Flow: $Q_g = 1.10\text{ Am}^3/\text{s}$ at $P = 70.0\text{ barg}$ ($\rho_g = 52.0\text{ kg/m}^3$, $\rho_l = 1110\text{ kg/m}^3$)
Allowable Superficial Gas Velocity: $v_g = 0.28\text{ m/s}$ (75% of flood)
-
Compute Required Packed Bed Height ($Z_{packing}$):
$$Z = N_{theor} \times HETP = 2.2 \times 1.35\text{ m} = 2.97\text{ m} \approx \mathbf{3.0\text{ meters (10 ft)}}$$ -
Calculate Required Contactor Inside Diameter:
$$A_{cross} = \frac{Q_g}{v_g} = \frac{1.10\text{ m}^3/\text{s}}{0.28\text{ m/s}} = 3.929\text{ m}^2$$
$$D = \sqrt{\frac{4 \times 3.929}{\pi}} = \sqrt{5.002} = 2.236\text{ m} \implies \text{Select } \mathbf{2.25\text{ m ID (90 inches)}}$.
Interactive Practice Drill: TEG Circulation Rate (L/G), Equilibrium Dew Point & Tray/Packing Sizing
Completed this lesson?
Record your study progress, build your daily streak, and unlock +25 XP toward your next engineering tier.
Connected ChemProCal Tool
Size Triethylene Glycol (TEG) gas dehydration contactor diameter (Souders-Brown), lean glycol circulation rate, regeneration reboiler duty, …