Kremser-Brown-Souders Equations for Dilute Absorption and Stripping
Kremser-Brown-Souders analytical equations for dilute absorption and stripping, fractional solute recovery, and stripping factor design.
1. Theoretical Foundations & Engineering Mechanics
Kremser-Brown-Souders Equations for Dilute Absorption and Stripping
The Kremser-Brown-Souders (KBS) equations provide explicit closed-form expressions for the fraction of solute absorbed (or stripped) in a multistage counter-current cascade without numerical iterations.
1. The Absorption Formula
For an absorber of $N$ theoretical equilibrium stages with gas feed $y_{in}$ and lean solvent $x_{in}$:
$$\phi_A = \frac{y_{in} - y_{out}}{y_{in} - m x_{in}} = \frac{A^{N+1} - A}{A^{N+1} - 1}$$
where $\phi_A$ is the fractional recovery of absorbable solute. In the special case where $A = 1.0$:
$$\phi_A = \frac{N}{N+1}$$
2. The Stripping Formula
For a stripper of $N$ theoretical stages removing volatile solute from liquid using stripping gas ($S = m V / L = 1/A$):
$$\phi_S = \frac{x_{in} - x_{out}}{x_{in} - y_{in} / m} = \frac{S^{N+1} - S}{S^{N+1} - 1}$$
3. Stage Requirements for Ultra-High Purity
Rearranging for the required theoretical stages $N$:
$$N = \frac{\ln\left[ \frac{y_{in} - m x_{in}}{y_{out} - m x_{in}} \left(1 - \frac{1}{A}\right) + \frac{1}{A} \right]}{\ln A}$$
When designing environmental tail gas scrubbers requiring $99.9\%$ recovery ($y_{in}/y_{out} = 1000$), the absorption factor must be maintained strictly at $A \ge 1.3$ to prevent stage counts from exceeding $15 - 20$.
2. Governing Equations & Mathematical Formulation
$$\frac{y_{in} - y_{out}}{y_{in} - m x_{in}} = \frac{A^{N+1} - A}{A^{N+1} - 1} \quad [\text{KBS Absorption}]$$
$$\frac{x_{in} - x_{out}}{x_{in} - y_{in}/m} = \frac{S^{N+1} - S}{S^{N+1} - 1} \quad [\text{KBS Stripping}]$$
$$N = \frac{\ln\left[ \frac{1 - \phi_A / A}{1 - \phi_A} \right]}{\ln A} \quad [\text{Stages for Purity } \phi_A]$$
$$\lim_{N \rightarrow \infty} \phi_A = A \quad (A < 1), \qquad \lim_{N \rightarrow \infty} \phi_A = 1.0 \quad (A \ge 1)$$
• Dilute solutions (straight equilibrium line $y^* = m x$ and straight operating line).
• Constant temperature and pressure across all stages.
• Zero solvent vaporization or condensation of carrier gas.
• 100% stage efficiency.
• Using the absorption formula for stripping or vice-versa; stripping uses $S = m V / L$ while absorption uses $A = L / (m V)$.
• Assuming that increasing stages beyond 10 can compensate for $A < 1.0$; as $N \rightarrow \infty$, recovery asymptotically caps at $A$.
• Ignoring residual solute in the lean solvent ($x_{in} > 0$); lean solvent contamination imposes a hard thermodynamic ceiling on achievable clean gas purity ($y_{out,min} = m x_{in}$).
• Failing to account for gas volume contraction when high concentrations ($>10\%$) of acid gas are absorbed.
3. Applied Engineering Worked Example
Standard industrial operating and sizing conditions.
Problem Statement:
A counter-current stripping column with $N = 4$ theoretical equilibrium stages strips dissolved benzene from contaminated wastewater using air. Given:
- Water rate $L = 1000\text{ kmol/h}$
- Stripping air rate $V = 100\text{ kmol/h}$
- Equilibrium constant $m = 18.0$
- Pure stripping air ($y_{in} = 0$)
Calculate the stripping factor $S$ and the percentage of benzene stripped from the water $\phi_S$.
Step-by-step Solution:
1. Calculate Stripping Factor $S$:
$$S = \frac{m V}{L} = \frac{18.0 \times 100\text{ kmol/h}}{1000\text{ kmol/h}} = \frac{1800}{1000} = \mathbf{1.80}$$
Since $S = 1.80 > 1.0$, the stripper operates in the favorable stripping regime.
-
Calculate $S^{N+1}$ ($N = 4 \implies N+1 = 5$):
$$S^5 = (1.80)^5 = 18.8957$$ -
Compute fractional removal $\phi_S$ via KBS formula:
$$\phi_S = \frac{S^{N+1} - S}{S^{N+1} - 1} = \frac{18.8957 - 1.80}{18.8957 - 1.0} = \frac{17.0957}{17.8957} = \mathbf{0.9553}$$
Conclusion: Exactly $95.53\%$ of the benzene is stripped from the water in 4 equilibrium stages.
Interactive Practice Drill: Kremser-Brown-Souders Equations for Dilute Absorption and Stripping
Completed this lesson?
Record your study progress, build your daily streak, and unlock +25 XP toward your next engineering tier.
Connected ChemProCal Tool
Size amine contactor columns, calculate rich solvent loading, circulation rate (GPM), regeneration steam/reboiler duty, and Claus …