1. Theoretical Foundations & Engineering Mechanics

Baffling Mechanics and Rushton Turbine Agitation

Mechanical agitation in cylindrical process vessels is vital for blending, solid suspension, gas dispersion, and heat transfer. In an unbaffled stirred vessel, the rotating impeller imparts centrifugal and tangential momentum to the liquid, causing the bulk fluid to rotate as a solid body with a central vortex that extends downward toward the impeller eye.

1. Vortex Hazards and Baffling Criteria

Operating an unbaffled tank in the turbulent regime ($Re > 10^4$) introduces severe operational penalties:
- Air Ingestion: The vortex reaches the impeller, sucking gas into the liquid and causing cavitation, impeller vibration, and mechanical seal failure.
- Gross Segregation: Floating particulates are spun outwards by centrifugal force without effective vertical top-to-bottom circulation.
- Power Limitation: Power draw drops dramatically because the relative fluid-blade velocity diminishes.

To convert swirling tangential flow into productive axial and radial circulating currents, vertical wall baffles are installed. Standard vessel geometry specifies:
- Number of Baffles: 4 equally spaced vertical flat strips.
- Baffle Width ($W$): $W = T/10$ to $T/12$ for turbulent Newtonian fluids, where $T$ is tank diameter.
- Baffle Clearance ($C_b$): A clearance of $C_b = W/5$ from the vessel wall prevents stagnant solid deposition behind the baffle.

2. The Rushton 6-Blade Disc Turbine (Standard Radial Impeller)

The Rushton turbine (standard geometry: $D = T/3$, with 6 vertical flat blades mounted on a central horizontal disc) is the industry benchmark for high-shear radial flow, gas-liquid dispersion, and liquid-liquid emulsification.
- Fluid is drawn axially into the center disc from above and below and accelerated radially outward into two high-velocity loops.
- In fully baffled turbulent flow ($Re > 10^4$), the Power Number ($N_p$) of a standard Rushton turbine reaches a constant asymptotic value:
$$N_p = \frac{P}{\rho N^3 D^5} \approx 5.0 - 5.5$$

3. Gas Dispersion and Power Cavity Sinks

When a gas (e.g., air, oxygen, hydrogen) is sparged beneath a Rushton turbine, gas collects behind the blades in low-pressure wake cavities (vortex cavities, clinging cavities, large cavities). This gas cushion reduces the effective drag on the blades, causing the gassed power draw ($P_g$) to drop substantially below the ungassed power draw ($P_0$):
$$\frac{P_g}{P_0} = f(Fl_g, Fr)$$
where $Fl_g = \frac{Q_g}{N D^3}$ is the gas aeration number and $Fr = \frac{N^2 D}{g}$ is the Froude number. For commercial fermenters and oxidation reactors, $P_g / P_0$ typically ranges from $0.40$ to $0.70$. Failing to account for this power drop leads to motor under-sizing when aeration is stopped.

2. Governing Equations & Mathematical Formulation

$$Re = \frac{\rho N D^2}{\mu}$$
$$P = N_p \rho N^3 D^5$$
$$\text{Standard Baffling: } W = \frac{T}{10} \text{ to } \frac{T}{12}, \quad C_b = \frac{W}{5}$$
$$\text{Aeration Flow Number: } Fl_g = \frac{Q_g}{N D^3}$$
$$\text{Vortex Depth (Unbaffled): } h_v = \frac{\omega^2 R^2}{2g}$$

💡 Formulated according to international process engineering standards and dimensionless groups.
📌 Key Engineering Assumptions

• Fully baffled cylindrical vessel with four wall baffles of width W = T/10.
• Operation is in the fully turbulent regime (Re > 10,000) where Np is independent of Re.
• Flat or dished vessel head with standard liquid depth equal to tank diameter (H = T).
• Ungassed Newtonian liquid with constant density and viscosity.

⚠️ Common Industrial Pitfalls

• Omitting baffles in turbulent tanks, resulting in a deep central vortex, motor unloading, and loss of mixing intensity.
• Sizing the electric drive motor based on gassed power P_g; when gas sparging is interrupted, power surges back to P_0, tripping the motor on thermal overload.
• Extending baffles all the way to the tank wall without clearance in crystallizers or slurry tanks, causing solid accumulation and dead zones.

3. Applied Engineering Worked Example

Design Problem Specification

A jacketed process reactor of diameter T = 1.80 m with liquid depth H = 1.80 m contains a water-based reaction mixture (density rho = 1050 kg/m3, viscosity mu = 2.5 mPa.s). It is equipped with four standard wall baffles and a standard 6-blade Rushton disc turbine of diameter D = 0.60 m (D = T/3) with Np = 5.2. The turbine operates at N = 180 rpm. Air is then sparged beneath the impeller at Q_g = 0.050 m3/s, causing P_g / P_0 = 0.62.

Step-by-Step Mathematical Derivation & Verification

Step 1: Convert Impeller Speed to SI Units
$$N = \frac{180\text{ rev}}{60\text{ s}} = 3.0\text{ rev/s}$$

Step 2: Check Impeller Reynolds Number
$$Re = \frac{\rho N D^2}{\mu} = \frac{(1050\text{ kg/m}^3)(3.0\text{ s}^{-1})(0.60\text{ m})^2}{0.0025\text{ Pa}\cdot\text{s}} = \frac{1134}{0.0025} = 453,600$$
Since $Re = 4.54 \times 10^5 \gg 10^4$, flow is in the fully turbulent regime where $N_p = 5.20$ is constant.

Step 3: Calculate Ungassed Shaft Power Draw (P_0)
$$P_0 = N_p \rho N^3 D^5 = 5.20 \times (1050\text{ kg/m}^3) \times (3.0\text{ s}^{-1})^3 \times (0.60\text{ m})^5$$
$$3.0^3 = 27, \quad 0.60^5 = 0.07776\text{ m}^5$$
$$P_0 = 5.20 \times 1050 \times 27 \times 0.07776 = 11,463\text{ W} = \mathbf{11.46\text{ kW}}$$

Step 4: Calculate Gassed Power Draw (P_g)
$$P_g = P_0 \times 0.62 = 11.463\text{ kW} \times 0.62 = \mathbf{7.11\text{ kW}}$$

Step 5: Size Motor with Mechanical Transmission Efficiency (85%)
The motor must be rated to handle the full ungassed load $P_0$ in case sparging trips:
$$P_{\text{motor}} = \frac{P_0}{\eta_{\text{mech}}} = \frac{11.46\text{ kW}}{0.85} = 13.48\text{ kW} \quad (18.1\text{ HP})$$
Standard commercial motor size: 15.0 kW (20 HP).

Interactive Practice Drill: Baffling, Vortex Prevention & Gas-Liquid Dispersion Impellers (Rushton Turbines)