1. Theoretical Foundations & Engineering Mechanics

Agitation Power and Mixing Hydrodynamics

Mechanical agitation in stirred tanks (reactors, fermenters, crystallizers, blenders) provides liquid blending, solids suspension, gas dispersion, and enhanced jacket heat transfer. The mechanical shaft power delivered to the liquid by a rotating impeller is governed by dimensional analysis.

1. Dimensionless Numbers in Mixing

• Mixing Reynolds Number ($Re_m$): Characterizes flow around the impeller:

$$Re_m = \frac{\rho N D^2}{\mu}$$

where $N$ is impeller rotational speed (rev/s) and $D$ is impeller diameter (m).

• Power Number ($N_p$): Dimensionless power drag coefficient:

$$N_p = \frac{P}{\rho N^3 D^5}$$

where $P$ is shaft power delivered to fluid (Watts).

• Froude Number ($Fr = N^2 D / g$): Characterizes vortex surface formation in unbaffled tanks.

2. Power Regimes in Standard Baffled Tanks

When tanks are equipped with 4 standard wall baffles (width $W = T/12$ or $T/10$ where $T$ is tank diameter), surface vortex formation is suppressed:

• Laminar Regime ($Re_m < 10$): Viscous dissipation dominates; $N_p$ is inversely proportional to $Re_m$:

$$N_p = \frac{K_L}{Re_m} \implies P = K_L \mu N^2 D^3$$

• Fully Turbulent Regime ($Re_m > 10^4$): Power Number becomes constant, completely independent of fluid viscosity $\mu$:

$$N_p = K_T \implies P = K_T \rho N^3 D^5$$

Standard values of $K_T$: Rushton 6-flat-blade turbine $N_p \approx 5.0 - 5.5$; Pitched-blade turbine (45°) $N_p \approx 1.27$; Marine propeller $N_p \approx 0.32$.

2. Governing Equations & Mathematical Formulation

$$Re_m = \frac{\rho N D^2}{\mu}$$
$$N_p = \frac{P}{\rho N^3 D^5}$$
$$P_{\text{laminar}} = K_L \mu N^2 D^3 \quad (Re_m < 10)$$
$$P_{\text{turbulent}} = K_T \rho N^3 D^5 \quad (Re_m > 10^4)$$

💡 Formulated according to international process engineering standards and dimensionless groups.
📌 Key Engineering Assumptions

• Tank is fully baffled (4 vertical baffles, width $T/10$ to $T/12$) preventing liquid swirling and central vortex drawdown.
• Liquid is Newtonian and single-phase with uniform density and viscosity.
• Impeller clearance off bottom is standard ($C = T/3$).

⚠️ Common Industrial Pitfalls

• Using rotational speed in RPM instead of rev/second in the power formula ($N = \text{RPM}/60$), causing a massive error by factor of $60^3 = 216,000$.
• Forgetting the 5th-power dependence on impeller diameter ($D^5$): scaling impeller diameter by 20% increases required power by $(1.2)^5 = 2.49$ (a 150% increase!).
• Omitting motor and gearbox mechanical drive losses (typically $\eta_m \approx 80-85\%$).

3. Applied Engineering Worked Example

Design Problem Specification

A standard baffled stirred tank (diameter $T = 2.0\text{ m}$) contains an aqueous solution ($\rho = 1080\text{ kg/m}^3$, $\mu = 2.50 \times 10^{-3}\text{ Pa}\cdot\text{s}$). A Rushton 6-flat-blade disk turbine with diameter $D = 0.67\text{ m}$ ($T/3$) rotates at $120\text{ RPM}$. In the turbulent regime, the turbine power number is $N_p = 5.20$.
Calculate:
1. The mixing Reynolds number $Re_m$ to confirm fully turbulent flow ($Re_m > 10^4$).
2. The power $P$ delivered to the fluid in kilowatts (kW).
3. The required motor electrical rating assuming a drivetrain efficiency of $\eta = 82\%$.

Step-by-Step Mathematical Derivation & Verification

Step 1: Rotational Speed and Reynolds Number
$$N = \frac{120\text{ RPM}}{60} = 2.00\text{ rev/s}$$
$$D^2 = (0.67)^2 = 0.4489\text{ m}^2$$
$$Re_m = \frac{\rho N D^2}{\mu} = \frac{1080 \times 2.00 \times 0.4489}{0.00250} = \frac{969.62}{0.00250} = 387,850$$
Since $Re_m = 3.88 \times 10^5 > 10^4$, the system is in the fully turbulent constant-$N_p$ regime.

Step 2: Shaft Power Calculation
$$N^3 = (2.0)^3 = 8.0\text{ s}^{-3}$$
$$D^5 = (0.67)^5 = 0.13501\text{ m}^5$$
$$P = N_p \cdot \rho N^3 D^5 = 5.20 \times 1080 \times 8.0 \times 0.13501$$
$$P = 44,928 \times 0.13501 = 6065.7\text{ Watts} = 6.066\text{ kW}$$

Step 3: Motor Electrical Power Rating
$$P_{\text{motor}} = \frac{P}{\eta} = \frac{6.066\text{ kW}}{0.82} = 7.398\text{ kW}$$
(Standard commercial motor selection: 7.5 kW or 10 HP motor).

Final Answer:
$Re_m = 3.88 \times 10^5$ (Turbulent); Fluid shaft power = 6.07 kW; Motor power = 7.40 kW.