Weisz-Prater Criterion for Internal Diffusion Limitations

Weisz-Prater criterion for internal pore diffusion, experimental diagnostic tests, eliminating requirement for intrinsic rate constants, and diagnostic limits.

⚡ Open Live Tool Practice Questions ↓

1. Theoretical Foundations & Engineering Mechanics

Weisz-Prater Criterion for Internal Pore Diffusion

Evaluating the classical Thiele modulus $\phi = R \sqrt{k_v / D_e}$ requires prior knowledge of the intrinsic rate constant $k_v$. However, in experimental catalyst research, $k_v$ is unknown because pore diffusion might already be disguising the data.

1. The Weisz-Prater Dimensionless Modulus ($C_{WP}$)

In 1954, P. B. Weisz and C. D. Prater eliminated $k_v$ by multiplying the effectiveness factor by the square of the Thiele modulus:
$$C_{WP} = \eta \phi^2 = \left( \frac{-r_{A,obs}' \rho_p}{k_v C_{As}} \right) \left( R_p^2 \frac{k_v}{D_e} \right) = \frac{-r_{A,obs}' \rho_p R_p^2}{D_e C_{As}}$$
All terms in $C_{WP}$ are directly measurable from a single laboratory experiment:
- $-r_{A,obs}'$: Observed reaction rate per unit mass of catalyst ($\text{mol}/(\text{kg}\cdot\text{s})$)
- $\rho_p$: Catalyst pellet density ($\text{kg/m}^3$)
- $R_p$: Pellet radius ($\text{m}$)
- $D_e$: Effective diffusivity ($\text{m}^2/\text{s}$)
- $C_{As}$: Reactant concentration at external pellet surface ($\text{mol/m}^3$)

2. Diagnostic Thresholds

  • $C_{WP} \ll 1.0$ (typically $C_{WP} < 0.3$ for first-order):
  • Internal pore diffusion resistance is negligible ($\eta \approx 1.0$). Observed rates are true intrinsic chemical kinetics.
  • $C_{WP} \gg 1.0$ (typically $C_{WP} > 3.0$):
  • Severe internal pore diffusion limitation ($\eta \ll 1.0$). Reactants cannot penetrate into the pellet interior.

3. Laboratory Pellet Crushing Test

If pellets are crushed to half size ($R_2 = R_1 / 2$):
- If observed rate $-r_{A,obs}'$ remains unchanged $\implies$ No pore diffusion limitation ($C_{WP} < 1$).
- If observed rate surges $\implies$ Severe pore diffusion limitation ($C_{WP} \gg 1$).

2. Governing Equations & Mathematical Formulation

$$C_{WP} = \frac{-r_{A,obs}' \rho_p R_p^2}{D_e C_{As}} = \eta \phi^2$$

$$C_{WP} < 0.3 \implies \eta > 0.95 \quad [\text{No Diffusion Limitation}]$$

$$C_{WP} > 3.0 \implies \eta < 0.30 \quad [\text{Severe Pore Diffusion Limitation}]$$

$$C_{As} = C_{Ab} - \frac{-r_{A,obs}' \rho_b}{k_c a_v} \quad [\text{Surface Concentration Correction}]$$

💡 Formulated according to international process engineering standards and dimensionless groups.
📌 Key Engineering Assumptions

• Isothermal catalyst pellet.
• Uniform pore structure and pellet density.
• External film concentration drop is negligible ($C_{As} \approx C_{Ab}$) or corrected via mass transfer balance.
• Single reference reaction species.

⚠️ Common Industrial Pitfalls

• Using bulk concentration $C_{Ab}$ instead of surface concentration $C_{As}$ when external film mass transfer resistance is also present.
• Assuming $C_{WP} < 1.0$ guarantees no external film resistance; Weisz-Prater tests internal diffusion only (use Mears criterion for external film).
• Confusing pellet mass rate $-r_A'$ with volume rate $-r_A$ ($-r_A = -r_A' \rho_p$).
• Neglecting changes in $D_e$ at high pressure where Knudsen diffusion transitions to bulk molecular diffusion.

3. Applied Engineering Worked Example

Design Problem Specification

Standard industrial operating and sizing conditions.

Step-by-Step Mathematical Derivation & Verification

Problem Statement:
In a laboratory packed bed, cracking of cumene on silica-alumina catalyst gives an observed rate of $-r_{A,obs}' = 0.0012\text{ mol}/(\text{kg}_{cat}\cdot\text{s})$. Given:
- Pellet radius $R_p = 2.5\text{ mm}$ ($0.0025\text{ m}$)
- Pellet density $\rho_p = 1200\text{ kg/m}^3$
- Effective diffusivity $D_e = 4.0 \times 10^{-7}\text{ m}^2/\text{s}$
- External surface concentration $C_{As} = 0.030\text{ mol/m}^3$
Calculate the Weisz-Prater criterion $C_{WP}$ and determine whether the experimental kinetic data reflects true intrinsic kinetics or is diffusion-controlled.

Step-by-step Solution:
1. Formulate the Weisz-Prater parameter:
$$C_{WP} = \frac{-r_{A,obs}' \rho_p R_p^2}{D_e C_{As}}$$

  1. Calculate numerator:
    $$-r_{A,obs}' \rho_p = (0.0012\text{ mol/(kg}\cdot\text{s)}) \times (1200\text{ kg/m}^3) = 1.44\text{ mol}/(\text{m}^3\cdot\text{s})$$
    $$R_p^2 = (0.0025\text{ m})^2 = 6.25 \times 10^{-6}\text{ m}^2$$
    $$\text{Numerator} = 1.44 \times 6.25 \times 10^{-6} = 9.00 \times 10^{-6}\text{ mol}/(\text{m}\cdot\text{s})$$

  2. Calculate denominator:
    $$\text{Denominator} = D_e C_{As} = (4.0 \times 10^{-7}\text{ m}^2/\text{s}) \times (0.030\text{ mol/m}^3) = 1.20 \times 10^{-8}\text{ mol}/(\text{m}\cdot\text{s})$$

  3. Compute $C_{WP}$:
    $$C_{WP} = \frac{9.00 \times 10^{-6}}{1.20 \times 10^{-8}} = \mathbf{750.0}$$

  4. Interpret Result:
    $$C_{WP} = 750.0 \gg 1.0$$
    Conclusion: The system is in the extreme pore-diffusion-limited regime ($\eta \approx 3 / \sqrt{750} = 3 / 27.4 = 0.11$). The experimental data reflects pore diffusion rates, NOT chemical kinetics! The catalyst pellets must be crushed to fine powder ($< 50\,\mu\text{m}$) before measuring intrinsic rate constants.

Interactive Practice Drill: Weisz-Prater Criterion for Internal Diffusion Limitations

Instant answer checking, step rationales, and tolerance scoring.
Question 1 of 1
Loading interactive questions...

Completed this lesson?

Record your study progress, build your daily streak, and unlock +25 XP toward your next engineering tier.

⚡

Connected ChemProCal Tool

Run numerical simulations with real physical property packages.
Binary Reactor & Dual Condenser Design

Reactor thermal design, binary VLE batch distillation, and dual-condenser adequacy sizing.

Verified Equations Engineering Tolerances
Launch Live Tool ⚡