ChemProCal Academy ChemProCal Academy Academy
🔥 1d Streak
⚡ 0 XP
⚙ + Open Calculator Login Sign Up
Learn / Transport Phenomena & Mechanical Ops / Flow through Packed & Fluidized Beds
Flow through Packed & Fluidized Beds 1 Practice Questions

Terminal Velocity & Entrainment (Elutriation) in Fluidized Beds

Models particle elutriation from fluidized beds, calculating the Transport Disengaging Height (TDH), elutriation rate constants ($K^*$), and cyclone dipleg trick-valve hydraulics for catalyst recovery.

Practice Questions ↓

1. Theoretical Foundations & Engineering Mechanics

Freeboard Entrainment, TDH, and Cyclone Diplegs

As gas bubbles burst at the surface of a fluidized bed, they violently eject catalyst fines into the vessel overhead space (the freeboard). Fine particles whose terminal settling velocity $u_t < u_0$ are permanently entrained, while coarser particles decelerate and fall back.

1. Transport Disengaging Height (TDH)

Solids flux decreases exponentially with elevation above the bed surface. The height at which solids flux stabilizes to an asymptotic minimum is the Transport Disengaging Height (TDH). Based on Zenz and Weil:

$$TDH \approx 1.0 \text{ to } 1.5 \times \text{vessel diameter (for bubbles up to 1 m)}$$

Locating cyclone inlets above TDH reduces solids loading to the cyclones by $> 80\%$, extending cyclone life and reducing catalyst losses.

2. Elutriation Rate Constant ($K_{i}^*$)

For particle size fraction $d_{p,i}$, the entrainment rate $E_i$ ($\text{kg/s}$) is modeled by Wen-Hashinger:

$$E_i = K_{i}^* \cdot A_{\text{bed}} \cdot x_i$$

where $x_i$ is the mass fraction of size $d_p$ in the bed and $K_{i}^*$ is the elutriation rate constant ($\text{kg}/(\text{m}^2\cdot\text{s})$).

3. Cyclone Dipleg and Trickle Valve Balance

Cyclones separate entrained catalyst and return it to the bed via a vertical dipleg sealed with a flapper or trickle valve. Because static pressure at the cyclone vortex core is lower than bed pressure, catalyst must build a static head in the dipleg ($h_{\text{leg}}$) to overcome the pressure differential and prevent gas backflow.

2. Governing Equations & Mathematical Formulation

$$E_i = K_i^* A_{\text{bed}} x_i$$
$$\frac{K_i^*}{\rho_g u_0} = 5.17 \times 10^{-4} \left( \frac{u_0 - u_{t,i}}{\sqrt{g d_{p,i}}} \right)^{1.2} \left( \frac{\rho_p}{\rho_g} \right)^{0.5}$$
$$h_{\text{dipleg}} = \frac{\Delta P_{\text{cyclone}} + \Delta P_{\text{bed}}}{\rho_{\text{aerated}} g}$$
$$L_{\text{dipleg, min}} = 1.5 \cdot h_{\text{dipleg}}$$

💡 Formulated according to international process engineering standards and dimensionless groups.
📌 Key Engineering Assumptions

• Freeboard height equals or exceeds TDH to ensure uniform inlet loading to secondary cyclones.
• Dipleg solids are aerated at minimum fluidization voidage without defluidization.
• Trickle valve flapper plate operates freely without mechanical binding or coking.

⚠️ Common Industrial Pitfalls

• Locating cyclone inlets below TDH, swamping cyclones with high solids fluxes and causing massive catalyst loss out the stack.
• Designing diplegs too short, causing gas to bypass up the dipleg and blow catalyst directly out of the cyclone.
• Ignoring trickle valve leakage during startup when dipleg head is not yet established.

3. Applied Engineering Worked Example

Design Problem Specification

In an FCC regenerator, a secondary cyclone has an inlet-to-dust-outlet differential pressure of $\Delta P_{\text{cyclone}} = 8.5\text{ kPa}$. The dipleg discharges into the fluidized bed where the local immersion pressure is $4.0\text{ kPa}$ higher than the vessel freeboard. Total pressure to overcome across the dipleg is $\Delta P = 8.5 + 4.0 = 12.5\text{ kPa}$. Aerated catalyst inside the dipleg has a bulk density of $\rho_{\text{bulk}} = 750\text{ kg/m}^3$. ($g = 9.81\text{ m/s}^2$).
Calculate:
1. The minimum catalyst level $h_{\text{cat}}$ required inside the dipleg to balance the pressure difference in meters.
2. The recommended total dipleg length $L_{\text{leg}}$ incorporating a standard 50% safety margin.

Step-by-Step Mathematical Derivation & Verification

Step 1: Calculate Hydrostatic Balance Height
$$\Delta P = \rho_{\text{bulk}} g h_{\text{cat}}$$
$$h_{\text{cat}} = \frac{\Delta P}{\rho_{\text{bulk}} g} = \frac{12,500\text{ Pa}}{750\text{ kg/m}^3 \times 9.81\text{ m/s}^2} = \frac{12,500}{7357.5} = 1.699\text{ m}$$

Step 2: Recommended Total Dipleg Length
Applying the standard 50% surge and safety factor:
$$L_{\text{leg}} = 1.50 \times h_{\text{cat}} = 1.50 \times 1.699\text{ m} = 2.548\text{ m}$$

Final Answer:
Minimum catalyst head $h_{\text{cat}} = 1.70$ m; Recommended dipleg length $L_{\text{leg}} = 2.55$ m.