Spiral Heat Exchangers for High-Solids and Slurry Duties
Spiral heat exchangers (SHE), single-channel concentric flow geometry, self-cleaning scouring mechanics, and particulate slurry applications.
1. Theoretical Foundations & Engineering Mechanics
Spiral Heat Exchangers & Slurry Processing
A Spiral Heat Exchanger (SHE) is fabricated by rolling two long, parallel metal plates around a central core (mandrel) to create two concentric, continuous spiral flow channels.
Self-Cleaning Scouring Effect:
- In conventional multi-tube shell and tube exchangers, if one tube fouls, fluid naturally diverts to the other parallel tubes. The fouled tube loses velocity, accelerates fouling, and eventually plugs completely.
- In contrast, a spiral exchanger has only one single channel per fluid. If particulate solids deposit in a localized zone, the local channel height narrows, which forces the fluid velocity to increase ($v = \dot{V} / A_{local}$). This localized velocity spike increases wall shear stress, scrubbing the deposit away and providing an intrinsic self-cleaning scouring mechanism.
Industrial Applications:
- Wastewater treatment sludges, fermentation broths, PVC slurries, paper pulp fibers, and alumina refinery digestion slurries.
- Full counter-current flow allows close approaches with viscous fluids.
2. Governing Equations & Mathematical Formulation
$$\text{Curvature Reynolds Number: } Re = \frac{\rho v d_h}{\mu}$$
$$\text{Dean Number: } De = Re \cdot \sqrt{\frac{d_h}{2 R_{curve}}}$$
$$\text{Centrifugal Secondary Flow Friction: } f_{spiral} = f_{straight} \cdot \left[ 1 + 0.075 De^{0.5} \right]$$
$$\text{Wall Shear Stress: } \tau_w = \frac{1}{2} f_{spiral} \cdot \rho v^2$$
• Curvature induces counter-rotating Dean vortices that disrupt the boundary layer and enhance heat transfer.
• Standard plate widths range from $0.3\text{ m}$ to $2.0\text{ m}$, with channel spacing from $5\text{ mm}$ to $25\text{ mm}$.
• Design pressures are generally limited to 15 to 25 bar by plate bending limits.
• Opening hinged covers without replacing the full perimeter elastomer gasket, causing bypass leakage between channels.
• Operating below the minimum recommended scouring velocity ($v < 0.6\text{ m/s}$) for heavy settling slurries.
• Using studded spacer pins in long-fiber applications (e.g. paper pulp), causing fibers to catch and bridge across pins.
3. Applied Engineering Worked Example
Slurry: Anaerobic digestate sludge ($12\%$ dry solids), $\dot{m} = 15\text{ kg/s}$, $\rho = 1040\text{ kg/m}^3$, apparent viscosity $\mu = 0.012\text{ Pa}\cdot\text{s}$
Spiral Channel: Width $W = 1.0\text{ m}$, Channel spacing $b = 12.0\text{ mm}$, Mean curve radius $R_{curve} = 0.60\text{ m}$
-
Calculate Channel Flow Area ($A_{ch}$):
$$A_{ch} = W \cdot b = 1.0 \times 0.012 = 0.0120\text{ m}^2$$ -
Calculate Fluid Velocity ($v$):
$$v = \frac{\dot{m}}{\rho A_{ch}} = \frac{15}{1040 \times 0.0120} = \frac{15}{12.48} = 1.202\text{ m/s}$$
Velocity exceeds the minimum scouring threshold of $0.8\text{ m/s}$. -
Calculate Hydraulic Diameter ($d_h$):
$$d_h = \frac{4 W b}{2 (W + b)} \approx 2 b = 2 \times 0.012 = 0.024\text{ m}$$ -
Calculate Reynolds Number and Dean Number:
$$Re = \frac{1040 \times 1.202 \times 0.024}{0.012} = 2,500$$
$$De = Re \sqrt{\frac{d_h}{2 R_{curve}}} = 2500 \times \sqrt{\frac{0.024}{2 \times 0.60}} = 2500 \times \sqrt{0.020} = 2500 \times 0.1414 = 353.5$$ -
Conclusion:
Strong Dean vortices ($De > 100$) provide self-cleaning scouring and enhance heat transfer by 35% compared to straight pipe.