ChemProCal Academy ChemProCal Academy Academy
🔥 1d Streak
⚡ 0 XP
⚙ + Open Calculator Login Sign Up
Learn / Mass Transfer Operations / Liquid-Liquid Extraction & Leaching
Liquid-Liquid Extraction & Leaching 8 Practice Questions ⚡ Live Calculator Connected

Solid-Liquid Leaching & Washing Calculations

Solid-liquid leaching principles, solid dissolution mechanisms, washing calculations, constant vs variable underflow, and counter-current decantation (CCD).

⚡ Open Live Tool Practice Questions ↓

1. Theoretical Foundations & Engineering Mechanics

Solid-Liquid Leaching & Washing Calculations

Leaching (solid extraction) dissolves a soluble solute from an inert insoluble solid matrix using a liquid solvent. Prominent applications include extracting vegetable oils (soybean, canola) with hexane, sugar from sugar beets with hot water, and gold/copper from ores with cyanide/sulfuric acid.

1. Phases in Leaching Operations

  • Overflow (Extract Phase): Clear liquid containing dissolved solute and solvent, virtually free of insoluble solids.
  • Underflow (Slurry / Sludge Phase): Insoluble inert solids carrying entrained solution.

2. Underflow Retention Models

  1. Constant Solution Underflow: The ratio of inert solid to retained liquid solution ($B/S_L$) is constant, independent of solute concentration. Yields linear, horizontal operating lines on Ponchon-Savarit type coordinates.
  2. Variable Underflow: Retained solution volume varies with solute concentration due to changes in liquid viscosity and settling rate. Higher solute concentration increases solution viscosity, causing the solids to retain more liquid (underflow line slopes downward).

3. Counter-Current Decantation (CCD)

In a CCD train of thickeners (sedimentation tanks), fresh solvent enters the final stage while fresh solid feed enters stage 1. Solute recovery efficiency is modeled via stage-wise material balances:
$$R = 1 - \left( \frac{1}{1 + S/L_{entrained}} \right)^N$$

2. Governing Equations & Mathematical Formulation

$$B = \text{Mass of Inert Insoluble Solid} = \text{Constant}$$

$$R_{underflow} = \frac{\text{Mass of Solution Retained}}{\text{Mass of Inert Solid}} = \text{Constant} \quad [\text{Constant Underflow}]$$

$$x_n = y_n \quad [\text{Equilibrium Assumption in Over/Underflow}]$$

$$F x_F + R_{n+1} x_{n+1} = E_n y_n + R_n x_n \quad [\text{Stage Balance}]$$

💡 Formulated according to international process engineering standards and dimensionless groups.
📌 Key Engineering Assumptions

• Complete dissolution of solute into solvent (equilibrium reached within each agitated stage).
• Solute concentration in the entrained underflow solution equals the overflow liquid concentration ($x_n = y_n$).
• Insoluble solid matrix is completely inert and does not dissolve.
• Zero solid carryover in the clarified overflow stream.

⚠️ Common Industrial Pitfalls

• Assuming underflow retention is constant when solute concentration varies widely; viscosity increases liquid drag, dramatically increasing underflow retention.
• Failing to grind solids to adequate particle size; uncrushed ore leaves solute trapped in interior pores, preventing solvent contact.
• Neglecting slow washing diffusion kinetics; solid-liquid separation requires residence time for solute to diffuse out of cellular matrices.
• Ignoring flocculant dosing requirements; without polymeric flocculants, fine solid particles remain suspended in overflow.

3. Applied Engineering Worked Example

Design Problem Specification

Standard industrial operating and sizing conditions.

Step-by-Step Mathematical Derivation & Verification

Problem Statement:
A counter-current leaching battery treats $1000\text{ kg/h}$ of inert solid containing $200\text{ kg/h}$ of soluble oil using $1200\text{ kg/h}$ of pure solvent. Underflow retention is constant at $0.50\text{ kg solution / kg inert solid}$. Calculate the mass of solution retained in the underflow and determine the mass of clarified overflow leaving the battery.

Step-by-step Solution:
1. Calculate solution retained in underflow:
- Inert solids $B = 1000\text{ kg/h}$
- Solution retention factor $R = 0.50\text{ kg/kg}$
$$L_{underflow} = B \times R = 1000\text{ kg/h} \times 0.50 = \mathbf{500\text{ kg/h solution}}$$

  1. Overall liquid balance:
    - Total liquid input $= \text{Soluble oil} + \text{Solvent} = 200 + 1200 = 1400\text{ kg/h}$
    $$\text{Total Liquid In} = \text{Overflow Liquid Out} + \text{Underflow Liquid Out}$$
    $$1400\text{ kg/h} = L_{overflow} + 500\text{ kg/h}$$
    $$L_{overflow} = 1400 - 500 = \mathbf{900\text{ kg/h}}$$

  2. Solid-Free Basis Check:
    The overflow discharges $900\text{ kg/h}$ of clarified solution containing $>90\%$ of the original oil.

Interactive Practice Drill: Solid-Liquid Leaching & Washing Calculations

Instant answer checking, step rationales, and tolerance scoring.
Question 1 of 8
Loading interactive questions...

Completed this lesson?

Record your study progress, build your daily streak, and unlock +25 XP toward your next engineering tier.

⚡

Connected ChemProCal Tool

Run numerical simulations with real physical property packages.
Chemical Property Explorer

Search the canonical registry for thermodynamics, physical properties, and phase behavior.

Verified Equations Engineering Tolerances
Launch Live Tool ⚡