Multiple Reactions & Selectivity 0 Practice Questions ⚡ Live Calculator Connected

Yield, Conversion & Selectivity Optimization under Non-Isothermal Conditions

Non-isothermal temperature progression for multiple reactions, activation energy trade-offs, optimum temperature trajectories, and cooling profiles.

⚡ Open Live Tool Practice Questions ↓

1. Theoretical Foundations & Engineering Mechanics

Non-Isothermal Temperature Progression for Multiple Reactions

When competing reactions have different activation energies, temperature is the most potent lever for selectivity control. Consider parallel reactions:
$$A \xrightarrow{k_1} D \quad (\text{Desired, activation energy } E_1)$$
$$A \xrightarrow{k_2} U \quad (\text{Undesired, activation energy } E_2)$$

1. Temperature Selection Rules Based on Activation Energies

The ratio of rate constants is:
$$\frac{k_1}{k_2} = \frac{A_1}{A_2} \exp\left( -\frac{E_1 - E_2}{R T} \right)$$
- Case 1: $E_1 > E_2$ (Desired reaction has higher activation energy):
- The rate of the desired reaction increases faster with temperature than the undesired reaction.
- Strategy: Operate at the highest possible temperature (limited only by catalyst thermal degradation, boiling point, or metallurgical limits).
- Case 2: $E_1 < E_2$ (Undesired reaction has higher activation energy):
- Higher temperatures favor the undesired pathway.
- Strategy: Operate at a low temperature to suppress byproduct formation, accepting a larger reactor volume penalty.

2. Reversible Exothermic Reactions: Optimum Temperature Progression

For reversible exothermic reactions ($A \rightleftharpoons R$, $-\Delta H > 0$):
- High rate requires high temperature ($k_{forward}$ surges).
- High equilibrium conversion requires low temperature (Le Chatelier shift).
- Optimum Temperature Progression: Temperature should start hot at the reactor inlet (where high driving force drives rapid initial conversion) and monotonically decrease along the reactor length (so cooling shifts the equilibrium conversion ceiling to $>95\%$ at the outlet).

2. Governing Equations & Mathematical Formulation

$$\frac{d(k_1/k_2)}{dT} = \frac{k_1}{k_2} \frac{E_1 - E_2}{R T^2}$$

$$T_{opt}(X) = \frac{E_1 - E_2}{R \ln\left[ \frac{E_2 A_2 (1-X)}{E_1 A_1 X} \right]} \quad [\text{Optimum Locus}]$$

$$K_{eq}(T) = K_0 \exp\left(-\frac{\Delta H^\circ}{R T}\right)$$

$$r_{net}(T, X) = k_1(T)(1 - X) - k_2(T) X$$

💡 Formulated according to international process engineering standards and dimensionless groups.
📌 Key Engineering Assumptions

• Arrhenius behavior holds across the entire operating temperature span.
• Heat of reaction is independent of temperature.
• Reactor heat transfer system can reliably execute the prescribed temperature trajectory.
• Catalyst does not undergo thermal deactivation at peak temperatures.

⚠️ Common Industrial Pitfalls

• Operating an exothermic reversible reactor isothermally at high temperature, which prematurely bottlenecks conversion against the low equilibrium limit.
• Ignoring that side reactions often have much higher activation energies ($E_{coke} > 150\text{ kJ/mol}$), causing coke generation to explode at hot spots.
• Failing to enforce minimum temperature limits; operating too cold extinguishes the reaction completely.
• Assuming that higher temperature always speeds up production; for $E_1 < E_2$, heating converts expensive feed into unwanted waste.

3. Applied Engineering Worked Example

Design Problem Specification

Standard industrial operating and sizing conditions.

Step-by-Step Mathematical Derivation & Verification

Problem Statement:
Reactant $A$ decomposes via two parallel reactions:
- Desired: $A \rightarrow D$, $E_1 = 120\text{ kJ/mol}$, $A_1 = 1.0 \times 10^{13}\text{ s}^{-1}$
- Undesired: $A \rightarrow U$, $E_2 = 70\text{ kJ/mol}$, $A_2 = 1.0 \times 10^7\text{ s}^{-1}$
Calculate the ratio $k_1 / k_2$ at $T = 350\text{ K}$ and at $T = 450\text{ K}$. What temperature strategy should be adopted?

Step-by-step Solution:
1. Formulate the rate constant ratio:
$$\Delta E = E_1 - E_2 = 120000 - 70000 = 50000\text{ J/mol}$$
$$\frac{A_1}{A_2} = \frac{1.0 \times 10^{13}}{1.0 \times 10^7} = 1.0 \times 10^6$$
$$\frac{k_1}{k_2} = 1.0 \times 10^6 \exp\left( -\frac{50000}{8.314 T} \right) = 1.0 \times 10^6 \exp\left( -\frac{6013.95}{T} \right)$$

  1. Calculate at $T = 350\text{ K}$:
    $$\frac{k_1}{k_2}(350) = 1.0 \times 10^6 \exp(-6013.95 / 350) = 1.0 \times 10^6 \exp(-17.183) = 1.0 \times 10^6 \times 3.448 \times 10^{-8} = \mathbf{0.0345}$$
    (At $350\text{ K}$, $96.7\%$ of feed goes to unwanted waste $U$!).

  2. Calculate at $T = 450\text{ K}$:
    $$\frac{k_1}{k_2}(450) = 1.0 \times 10^6 \exp(-6013.95 / 450) = 1.0 \times 10^6 \exp(-13.364) = 1.0 \times 10^6 \times 1.570 \times 10^{-6} = \mathbf{1.570}$$
    (At $450\text{ K}$, desired product $D$ now dominates over byproduct $U$).

  3. Engineering Recommendation:
    Because $E_1 > E_2$, operate at the highest permissible temperature to maximize selectivity toward $D$.

Interactive Practice Drill: Yield, Conversion & Selectivity Optimization under Non-Isothermal Conditions

Instant answer checking, step rationales, and tolerance scoring.
Question 1 of 15
Loading interactive questions...

Completed this lesson?

Record your study progress, build your daily streak, and unlock +25 XP toward your next engineering tier.

⚡

Connected ChemProCal Tool

Run numerical simulations with real physical property packages.
Heat Exchanger Rating

Verified Equations Engineering Tolerances
Launch Live Tool ⚡