Isentropic Compression, Expansion & Turbines
Isentropic vs polytropic expansion and compression, ideal gas isentropic relationships (P-V-T), isentropic efficiency, and nozzle choked expansion.
1. Theoretical Foundations & Engineering Mechanics
Isentropic Compression & Expansion Thermodynamics
An isentropic process is both internally reversible and adiabatic ($ds = 0$). It serves as the idealized benchmark against which real gas compressors, blowers, steam turbines, and turboexpanders are evaluated.
1. Ideal Gas Isentropic Relationships
For an ideal gas with constant heat capacities ($k = C_p / C_v$):
$$P v^k = \text{constant}$$
$$\frac{T_2}{T_1} = \left( \frac{P_2}{P_1} \right)^{\frac{k-1}{k}} = \left( \frac{v_1}{v_2} \right)^{k-1}$$
2. Compressor Isentropic Work & Efficiency
In compression, real irreversible fluid friction generates internal entropy, requiring more shaft work than the ideal reversible isentropic path ($h_{2,act} > h_{2s}$):
$$W_{isentropic} = \frac{k}{k - 1} Z R T_1 \left[ \left( \frac{P_2}{P_1} \right)^{\frac{k-1}{k}} - 1 \right]$$
$$\eta_{is,comp} = \frac{W_{isentropic}}{W_{actual}} = \frac{h_{2s} - h_1}{h_{2,act} - h_1} < 1.0$$
3. Turbine / Expander Isentropic Efficiency
In expansion, irreversible losses reduce the shaft work delivered by the fluid ($h_1 - h_{2,act} < h_1 - h_{2s}$):
$$\eta_{is,turb} = \frac{W_{actual}}{W_{isentropic}} = \frac{h_1 - h_{2,act}}{h_1 - h_{2s}} < 1.0$$
2. Governing Equations & Mathematical Formulation
$$T_{2s} = T_1 \left( \frac{P_2}{P_1} \right)^{\frac{k-1}{k}}$$
$$W_{is,comp} = \dot{m} (h_{2s} - h_1) = \dot{m} C_p T_1 \left[ \left(\frac{P_2}{P_1}\right)^{\frac{k-1}{k}} - 1 \right]$$
$$W_{actual,comp} = \frac{W_{is,comp}}{\eta_{is}}$$
$$T_{2,actual} = T_1 + \frac{T_{2s} - T_1}{\eta_{is}}$$
• Constant ratio of specific heats ($k$) across pressure compression range.
• Negligible heat loss through casing (near-adiabatic operation).
• Inlet compressibility factor ($Z_1$) accounts for initial non-ideality.
• Defining compressor isentropic efficiency as actual divided by isentropic (which would give $\eta > 1.0$; for compressors it is always ideal divided by actual).
• Forgetting that discharge temperature in real compressors is higher than isentropic temperature due to frictional dissipation ($T_{2,act} > T_{2s}$).
• Sizing multi-stage compressors with single-stage equations without intercooling.
3. Applied Engineering Worked Example
Fluid: Pure Methane ($M = 16.04\text{ kg/kmol}$, $k = 1.31 \implies \frac{k-1}{k} = \frac{0.31}{1.31} = 0.2366$, $C_p = 2.23\text{ kJ/(kg}\cdot\text{K)}$)
Inlet: $P_1 = 5.0\text{ bara}$, $T_1 = 20^\circ\text{C} = 293.15\text{ K}$, $\dot{m} = 10.0\text{ kg/s}$
Outlet: $P_2 = 20.0\text{ bara}$ (Pressure ratio $r_p = 4.0$)
Compressor Efficiency: Isentropic efficiency $\eta_{is} = 78\% = 0.78$
-
Compute Ideal Isentropic Discharge Temperature ($T_{2s}$):
$$T_{2s} = 293.15 \times (4.0)^{0.2366} = 293.15 \times 1.3887 = 407.1\text{ K} = 133.95^\circ\text{C}$$
$$\Delta T_s = 407.1 - 293.15 = 113.95\text{ K}$$ -
Compute Actual Discharge Temperature ($T_{2,act}$):
$$\Delta T_{act} = \frac{\Delta T_s}{\eta_{is}} = \frac{113.95}{0.78} = 146.09\text{ K}$$
$$T_{2,act} = 293.15 + 146.09 = 439.24\text{ K} = \mathbf{166.1^\circ\text{C}}$$ -
Compute Actual Shaft Power Required:
$$\dot{W}_{act} = \dot{m} C_p \Delta T_{act} = 10.0\text{ kg/s} \times 2.23\text{ kJ/(kg}\cdot\text{K)} \times 146.09\text{ K} = 3,257.8\text{ kW} = \mathbf{3.26\text{ MW}}$$
Interactive Practice Drill: Isentropic Compression, Expansion & Turbines