First-Order Process Dynamics & Step Responses
Explores the dynamic response of first-order chemical process systems, detailing the physical significance of process gain and time constant, analytical solutions to step, impulse, and sinusoidal forcing, and industrial tank drainage models.
1. Theoretical Foundations & Engineering Mechanics
First-Order Linear Processes
A process whose dynamic behavior is described by a first-order linear differential equation is known as a first-order system. In standard gain-time constant format, the governing ODE in deviation variables is:
$$\tau \frac{dy'(t)}{dt} + y'(t) = K_p u'(t)$$
Applying the Laplace transform yields the canonical first-order transfer function:
$$G(s) = \frac{Y(s)}{U(s)} = \frac{K_p}{\tau s + 1}$$
Where:
- $K_p = \lim_{s \to 0} G(s) = \frac{\Delta y(\infty)}{\Delta u}$ is the static process gain, representing the steady-state sensitivity of output to input change.
- $\tau$ is the process time constant, possessing units of time and governing the speed of system response.
Step Response Characteristics
When subjected to a step input of magnitude $M$ ($u'(t) = M$, $U(s) = M/s$):
$$Y(s) = \frac{K_p M}{s(\tau s + 1)} = K_p M \left[ \frac{1}{s} - \frac{\tau}{\tau s + 1} \right]$$
Inverting back to the time domain:
$$y'(t) = K_p M \left(1 - e^{-t/\tau}\right)$$
Universal benchmarks for the first-order step response:
- At $t = \tau$: $y'(\tau) = K_p M (1 - e^{-1}) = 0.6321 K_p M$ (63.2% completion).
- At $t = 2\tau$: $y'(2\tau) = K_p M (1 - e^{-2}) = 0.8647 K_p M$ (86.5% completion).
- At $t = 3\tau$: $y'(3\tau) = K_p M (1 - e^{-3}) = 0.9502 K_p M$ (95.0% completion).
- At $t = 4\tau$: $y'(4\tau) = K_p M (1 - e^{-4}) = 0.9817 K_p M$ (98.2% completion; practical steady state).
- Initial slope at $t = 0$: $\left.\frac{dy'}{dt}\right|_{t=0} = \frac{K_p M}{\tau}$. A straight line tangent to the response curve at $t=0$ intercepts the final steady state at precisely $t = \tau$.
Integrating Systems (Non-Self-Regulating)
When an exit valve operates via a positive displacement pump (constant volumetric discharge independent of liquid level), the resistance $R \to \infty$. The governing ODE becomes:
$$A \frac{dh'(t)}{dt} = q'_{in}(t) \implies G(s) = \frac{H(s)}{Q_{in}(s)} = \frac{1}{A s} = \frac{K^*}{s}$$
Such processes lack self-regulation: any constant step imbalance causes the level to ramp indefinitely toward vessel overflow or dry-out.
2. Governing Equations & Mathematical Formulation
$$\tau \frac{dy'}{dt} + y' = K_p u'(t)$$
$$G(s) = \frac{K_p}{\tau s + 1}$$
$$y'(t) = K_p M (1 - e^{-t/\tau})$$
$$\left.\frac{dy'}{dt}\right|_{t=0} = \frac{K_p M}{\tau}$$
$$G_{integrating}(s) = \frac{K^*}{s}$$
• The discharge resistance valve obeys a linear head-flow relationship ($q_{out} = h/R$) over the perturbation range.
• Fluid density remains strictly constant (incompressible flow).
• The cross-sectional area of the surge drum is uniform with elevation ($A(h) = \text{constant}$).
• There is no transport delay between the inflow nozzle and the level sensing element.
• Confusing the process gain $K_p$ with the time constant $\tau$, particularly when units are not tracked rigorously.
• Assuming an integrating process ($K^*/s$) will reach a finite steady state without active closed-loop feedback.
• Mistaking the initial slope tangent line for the actual exponential trajectory, expecting 100% completion at $t = \tau$ instead of the true 63.2%.
• Neglecting non-linear valve hydraulics where $q_{out} = C_v \sqrt{h}$, which requires Taylor linearization: $R = 2\sqrt{h_s} / C_v$.
3. Applied Engineering Worked Example
Standard industrial operating and sizing conditions.
Problem Statement:
A vertical condensate flash surge tank has cross-sectional area $A = 3.60\text{ m}^2$ and drains through a control valve characterized by linear resistance $R = 1.80\text{ min/m}^2$. At initial steady state, condensate liquid enters at $q_{in,s} = 1.20\text{ m}^3/\text{min}$, establishing steady liquid level $h_s = 2.16\text{ m}$.
At $t = 0$, a sudden upstream process swing steps incoming flow up to $1.65\text{ m}^3/\text{min}$ ($M = +0.45\text{ m}^3/\text{min}$).
1. Determine the process time constant $\tau$ and static process gain $K_p$.
2. Formulate the dynamic level equation $h(t)$.
3. Calculate the liquid level in the drum at $t = 5.0\text{ min}$ and $t = 25.0\text{ min}$.
4. Calculate the time elapsed until the level reaches $2.80\text{ m}$.
Step-by-Step Analytical Solution:
-
Time constant $\tau$ and gain $K_p$:
Total liquid mass balance: $A \frac{dh}{dt} = q_{in} - \frac{h}{R}$
In deviation variables: $A R \frac{dh'}{dt} + h' = R q'_{in}$
$$\tau = A R = (3.60\text{ m}^2)(1.80\text{ min/m}^2) = 6.48\text{ min}$$
$$K_p = R = 1.80\text{ m}/(\text{m}^3/\text{min})$$ -
Dynamic level response $h(t)$:
$$h'(t) = K_p M (1 - e^{-t/\tau}) = (1.80)(0.45)(1 - e^{-t/6.48}) = 0.81 (1 - e^{-t/6.48})$$
$$h(t) = h_s + h'(t) = 2.16 + 0.81 (1 - e^{-t/6.48})\text{ m}$$ -
Level evaluation:
- At $t = 5.0\text{ min}$:
$$h(5.0) = 2.16 + 0.81 \left(1 - e^{-5.0/6.48}\right) = 2.16 + 0.81(1 - 0.4623) = 2.16 + 0.4355 = \mathbf{2.596\text{ m}}$$
- At $t = 25.0\text{ min}$:
$$h(25.0) = 2.16 + 0.81 \left(1 - e^{-25.0/6.48}\right) = 2.16 + 0.81(1 - 0.0211) = 2.16 + 0.7929 = \mathbf{2.953\text{ m}}$$ -
Time to reach $h = 2.80\text{ m}$:
$$h' = 2.80 - 2.16 = 0.64\text{ m}$$
$$0.64 = 0.81 (1 - e^{-t/6.48}) \implies e^{-t/6.48} = 1 - \frac{0.64}{0.81} = 0.2099$$
$$t = -6.48 \ln(0.2099) = (-6.48)(-1.5612) = \mathbf{10.12\text{ min}}$$