Dispersion Model & Tanks-in-Series Model
Non-ideal flow modeling, Tanks-in-Series (TIS) parameter matching, Axial Dispersion Model (ADM), and vessel dispersion numbers.
1. Theoretical Foundations & Engineering Mechanics
Tanks-in-Series & Axial Dispersion Models
To predict chemical conversion in a non-ideal reactor using RTD data, two single-parameter models are standard in industrial chemical engineering:
1. Tanks-in-Series (TIS) Model
The real reactor is modeled as a cascade of $N$ equal-sized ideal CSTRs in series having total volume $V = N V_i$. The theoretical RTD for an $N$-tank cascade is:
$$E(\theta) = \frac{N (N \theta)^{N-1}}{(N-1)!} e^{-N \theta} \quad [\theta = t / \bar{t}]$$
The dimensionless variance of this distribution is directly related to the number of tanks:
$$\sigma_\theta^2 = \frac{\sigma^2}{\bar{t}^2} = \frac{1}{N} \implies N = \frac{\bar{t}^2}{\sigma^2}$$
- If $N = 1$: Ideal single CSTR.
- If $N \rightarrow \infty$: Ideal PFR.
- Fractional values of $N$ can be accommodated using the Gamma function $\Gamma(N)$.
2. Axial Dispersion Model (ADM)
The ADM superimposes Fickian axial back-mixing onto an ideal plug flow velocity profile:
$$\frac{\partial C}{\partial t} = D_a \frac{\partial^2 C}{\partial z^2} - u \frac{\partial C}{\partial z} + r_A$$
where $D_a$ is the axial dispersion coefficient ($\text{m}^2/\text{s}$) and $u$ is the interstitial velocity. The extent of non-ideality is quantified by the Vessel Dispersion Number ($D_a / u L = 1/Pe$):
- $D_a / u L \rightarrow 0$: Negligible dispersion (pure PFR).
- $D_a / u L \rightarrow \infty$: Infinite dispersion (pure CSTR).
For small dispersion ($D_a / u L < 0.05$):
$$\sigma_\theta^2 = 2 \left( \frac{D_a}{u L} \right)$$
2. Governing Equations & Mathematical Formulation
$$N = \frac{\bar{t}^2}{\sigma^2} = \frac{1}{\sigma_\theta^2} \quad [\text{Tanks in Series}]$$
$$\sigma_\theta^2 = 2 \left(\frac{D_a}{u L}\right) - 2 \left(\frac{D_a}{u L}\right)^2 \left(1 - e^{-u L / D_a}\right) \quad [\text{Closed-Closed}]$$
$$\sigma_\theta^2 \approx 2 \left(\frac{D_a}{u L}\right) \quad [\text{Small Dispersion}]$$
$$X_{A, TIS} = 1 - \frac{1}{(1 + k \bar{t} / N)^N} \quad [\text{1st Order}]$$
• Unidirectional axial dispersion with no radial velocity or concentration gradients.
• Axial dispersion coefficient $D_a$ is uniform along the vessel length.
• Tanks-in-series stages are of equal volume and completely mixed.
• Steady flow conditions.
• Using the small dispersion approximation ($2 D_a/u L$) when dispersion is large ($D_a/u L > 0.05$), introducing significant error.
• Confusing molecular diffusion $D_{AB}$ (order $10^{-9}\text{ m}^2/\text{s}$) with turbulent convective axial dispersion $D_a$ (order $10^{-4}$ to $10^{-1}\text{ m}^2/\text{s}$).
• Assuming $N$ must be an integer in the TIS model; fractional $N$ represents real intermediate mixing states.
• Applying ADM to vessels with extensive internal recirculation or gross bypassing.
3. Applied Engineering Worked Example
Standard industrial operating and sizing conditions.
Problem Statement:
Using the RTD data from the previous topic ($\bar{t} = 13.235\text{ min}$, $\sigma^2 = 32.18\text{ min}^2$, $\sigma_\theta^2 = 0.1837$):
1. Calculate the equivalent number of tanks in series $N$.
2. Calculate the vessel dispersion number $D_a / (u L)$ using the small dispersion formula.
3. Estimate the conversion of a first-order liquid reaction ($k = 0.15\text{ min}^{-1}$) using the Tanks-in-Series model.
Step-by-step Solution:
1. Calculate Tanks-in-Series parameter $N$:
$$N = \frac{1}{\sigma_\theta^2} = \frac{1}{0.1837} = \mathbf{5.44\text{ tanks}}$$
-
Calculate Vessel Dispersion Number:
$$\sigma_\theta^2 \approx 2 \left( \frac{D_a}{u L} \right) \implies \frac{D_a}{u L} = \frac{0.1837}{2} = \mathbf{0.0918}$$
(Péclet number $Pe = u L / D_a = 1 / 0.0918 = 10.89$). -
Calculate conversion for 1st-order reaction ($k = 0.15\text{ min}^{-1}$):
- Single tank Damköhler: $k \tau_i = k \bar{t} / N = \frac{0.15 \times 13.235}{5.44} = \frac{1.985}{5.44} = 0.3649$
- Unconverted fraction:
$$\frac{C_A}{C_{A0}} = (1 + k \tau_i)^{-N} = (1 + 0.3649)^{-5.44} = (1.3649)^{-5.44}$$
$$\ln(C_A/C_{A0}) = -5.44 \times \ln(1.3649) = -5.44 \times 0.3111 = -1.6923$$
$$\frac{C_A}{C_{A0}} = e^{-1.6923} = 0.1841$$
- Conversion:
$$X_A = 1 - 0.1841 = \mathbf{81.59\%}$$
(For comparison: ideal PFR would achieve $X_A = 1 - e^{-1.985} = 86.26\%$; non-ideality lowers conversion by $4.67\%$).
Interactive Practice Drill: Dispersion Model & Tanks-in-Series Model
Completed this lesson?
Record your study progress, build your daily streak, and unlock +25 XP toward your next engineering tier.
Connected ChemProCal Tool
Reactor thermal design, binary VLE batch distillation, and dual-condenser adequacy sizing.