Bernoulli Equation & Total Dynamic Head
Formulates the mechanical energy balance (extended Bernoulli equation) for incompressible pipe flow, accounting for pump shaft work, turbine expansion, and frictional head losses.
1. Theoretical Foundations & Engineering Mechanics
The Engineering Bernoulli Equation
For steady, incompressible flow along a streamline, the total mechanical energy of a fluid is conserved in the absence of friction. In practical chemical engineering piping networks, energy dissipation due to wall friction and turbulence is quantified as frictional head loss ($h_L$), and mechanical energy is introduced via pumps ($h_p$) or extracted via turbines ($h_t$).
1. Mechanical Energy Balance (Head Form)
Dividing all terms by $g$ yields the head formulation in units of length (meters of fluid):
$$\frac{P_1}{\rho g} + \frac{\alpha_1 u_1^2}{2g} + z_1 + h_p = \frac{P_2}{\rho g} + \frac{\alpha_2 u_2^2}{2g} + z_2 + h_t + h_L$$
where:
• $\frac{P}{\rho g}$ = Pressure Head (m)
• $\frac{\alpha u^2}{2g}$ = Velocity Head (m), with kinetic energy correction factor $\alpha = 2$ for laminar and $\alpha \approx 1.05$ for turbulent flow
• $z$ = Elevation Head (m)
• $h_p = \frac{\dot{W}_p}{\dot{m} g}$ = Pump Head added to fluid (m)
• $h_L$ = Total frictional head loss (m)
2. Total Dynamic Head (TDH) and Pump Hydraulic Power
The Total Dynamic Head ($TDH = h_p$) that a centrifugal pump must develop is:
$$TDH = \left(\frac{P_2 - P_1}{\rho g}\right) + (z_2 - z_1) + \left(\frac{u_2^2 - u_1^2}{2g}\right) + h_L$$
The hydraulic power delivered to the fluid is $\dot{W}_{hyd} = \dot{m} g \cdot TDH = \Delta P_{\text{pump}} \cdot \dot{V}$. Brake horsepower (BHP) required by the pump motor accounts for mechanical and hydraulic efficiency $\eta$:
$$P_{\text{motor}} = \frac{\dot{W}_{hyd}}{\eta} = \frac{\rho g \dot{V} \cdot TDH}{\eta}$$
2. Governing Equations & Mathematical Formulation
$$\frac{P_1}{\rho g} + \frac{u_1^2}{2g} + z_1 + h_p = \frac{P_2}{\rho g} + \frac{u_2^2}{2g} + z_2 + h_L$$
$$TDH = \frac{\Delta P_{\text{system}}}{\rho g} + \Delta z + h_L$$
$$\dot{W}_{hyd} = \rho g \dot{V} \cdot TDH$$
$$P_{\text{brake}} = \frac{\dot{W}_{hyd}}{\eta}$$
• Flow is steady, continuous, and incompressible (Mach number $Ma < 0.3$).
• Fluid properties (density $\rho$ and viscosity $\mu$) are constant throughout the piping system.
• Kinetic energy correction factor $\alpha \approx 1.0$ is applicable for fully developed turbulent flow.
• Confusing static pressure head with total dynamic head by omitting line friction losses.
• Using fluid density in pump power calculations without checking units ($\text{kg/m}^3$ vs $\text{g/cm}^3$).
• Forgetting that pump suction and discharge reservoir surface velocities are effectively zero ($u_1 = u_2 \approx 0$) for large tanks.
3. Applied Engineering Worked Example
A centrifugal pump transfers water ($\rho = 1000\text{ kg/m}^3$, $\mu = 1.0\text{ cP}$) from an open feed storage tank at atmospheric pressure to an overhead reactor operating at $2.0\text{ bar gauge}$ ($200\text{ kPa gauge}$). The reactor inlet is located $18.0\text{ m}$ above the suction tank liquid level. Flow rate is $50.0\text{ m}^3/\text{h}$. Total piping friction loss is estimated at $h_L = 8.5\text{ m}$. Pump efficiency is $\eta = 72\%$. ($g = 9.81\text{ m/s}^2$).
Calculate:
1. The Total Dynamic Head ($TDH$) required from the pump in meters.
2. The brake electrical power required by the pump motor in kilowatts (kW).
Step 1: Calculate Pressure Head Difference
$$\Delta P = P_2 - P_1 = 200,000 - 0 = 200,000\text{ Pa}$$
$$h_{\Delta P} = \frac{200,000}{1000 \times 9.81} = 20.39\text{ m}$$
Step 2: Total Dynamic Head (TDH)
Elevation difference: $\Delta z = z_2 - z_1 = 18.0\text{ m}$.
Velocity head difference: $\Delta (u^2/2g) \approx 0$ (large reservoir to reactor).
Friction loss: $h_L = 8.5\text{ m}$.
$$TDH = h_{\Delta P} + \Delta z + h_L = 20.39 + 18.0 + 8.5 = 46.89\text{ m}$$
Step 3: Hydraulic and Motor Brake Power
Volumetric flow rate: $\dot{V} = 50.0 / 3600 = 0.01389\text{ m}^3/\text{s}$.
Hydraulic power:
$$\dot{W}_{hyd} = \rho g \dot{V} \cdot TDH = 1000 \times 9.81 \times 0.01389 \times 46.89 = 6390.6\text{ W} = 6.391\text{ kW}$$
Motor brake power:
$$P_{\text{brake}} = \frac{\dot{W}_{hyd}}{\eta} = \frac{6.391}{0.72} = 8.876\text{ kW}$$
Final Answer:
Pump TDH = 46.89 m; Motor brake power = 8.88 kW.