Atmospheric Storage Tank Sizing (API 650 1-Foot Method)
Sizes atmospheric welded steel storage tanks per API Standard 650 using the One-Foot Method, calculating shell course thicknesses, hydrostatic test water limits, and allowable product stresses.
1. Theoretical Foundations & Engineering Mechanics
API 650 Storage Tank Design and the One-Foot Method
Large cylindrical aboveground storage tanks storing petroleum, chemicals, and bio-fuels at internal pressures up to $18\text{ kPa}$ ($2.5\text{ psig}$) are governed internationally by API Standard 650 (Welded Tanks for Oil Storage).
1. The One-Foot Method Formulation
Because hydrostatic liquid pressure decreases linearly from bottom to top, storage tanks are built from stepped circumferential shell courses (typically $1.8$ to $2.4\text{ m}$ height per course). Liquid pressure creates hoop stress. The One-Foot Method calculates required plate thickness at a design point located exactly $1.0\text{ foot}$ ($0.3\text{ m}$) above the bottom weld seam of each course:
• Design Condition (Corroded Shell with Stored Liquid):
$$t_d = \frac{4.9 D (H - 0.3) G}{S_d} + CA$$
• Hydrostatic Test Condition (Uncorroded Shell with Clean Water):
$$t_t = \frac{4.9 D (H - 0.3)}{S_t}$$
where:
• $t_d, t_t$ are shell thicknesses in millimeters
• $D$ is nominal tank diameter in meters
• $H$ is design liquid height in meters (from bottom of course to maximum liquid level / overflow)
• $G$ is specific gravity of the stored liquid (minimum $G=1.0$ if liquid is lighter than water, for test evaluation)
• $S_d, S_t$ are allowable stresses for design and hydrotest conditions from API 650 Table 5-2 (MPa)
• $CA$ is specified corrosion allowance (mm).
The governing thickness for plate procurement is $t_{\text{gov}} = \max(t_d, t_t)$.
2. Governing Equations & Mathematical Formulation
$$t_d = \frac{4.9 D (H - 0.3) G}{S_d} + CA$$
$$t_t = \frac{4.9 D (H - 0.3)}{S_t}$$
$$t_{\text{req}} = \max(t_d, t_t) \ge t_{\text{code, min}}$$
$$t_{\text{min}} = 6.0\text{ mm} \quad (D > 36\text{ m})$$
• Tank diameter $D < 60\text{ m}$ ($200\text{ ft}$) for One-Foot Method validity; larger tanks require Variable-Design-Point method.
• Foundation settlement is uniform without edge shear failure.
• Operating internal pressure is atmospheric ($P \le 2.5\text{ psig}$).
• Sizing shell courses solely for stored product ($t_d$) and forgetting the water hydrotest condition ($t_t$); for light hydrocarbons ($G < 0.85$), water hydrotest governs thickness.
• Violating API 650 minimum nominal plate thickness rules ($5\text{ mm}$ to $10\text{ mm}$ based on diameter).
• Adding corrosion allowance to the hydrostatic test formula.
3. Applied Engineering Worked Example
An API 650 crude oil storage tank has diameter $D = 30.0\text{ m}$ and design liquid height $H = 15.0\text{ m}$. Design parameters:
• Stored product specific gravity: $G = 0.86$
• Corrosion allowance: $CA = 2.0\text{ mm}$
• Shell material: A36 Carbon Steel
• Allowable product stress: $S_d = 160.0\text{ MPa}$
• Allowable hydrotest stress: $S_t = 171.0\text{ MPa}$
Calculate:
1. The required bottom shell course thickness for product operating condition $t_d$ (mm).
2. The required thickness for hydrostatic water test condition $t_t$ (mm).
3. Select the governing thickness for the bottom shell course.
Step 1: Design Condition Thickness ($t_d$)
$$H - 0.3 = 15.0 - 0.3 = 14.7\text{ m}$$
$$t_d = \frac{4.9 D (H - 0.3) G}{S_d} + CA$$
$$t_d = \frac{4.9 \times 30.0 \times 14.7 \times 0.86}{160.0} + 2.0 = \frac{1858.31}{160.0} + 2.0 = 11.614 + 2.0 = 13.61\text{ mm}$$
Step 2: Hydrostatic Test Condition Thickness ($t_t$)
$$t_t = \frac{4.9 D (H - 0.3)}{S_t} = \frac{4.9 \times 30.0 \times 14.7}{171.0} = \frac{2160.90}{171.0} = 12.637\text{ mm}$$
Step 3: Governing Plate Selection
$$t_{\text{gov}} = \max(13.61, 12.64) = 13.61\text{ mm}$$
The design condition governs due to the 2.0 mm corrosion allowance. Commercial plate selection: 14.0 mm plate.
Final Answer:
Design thickness $t_d = 13.61$ mm; Test thickness $t_t = 12.64$ mm; Governing thickness = 13.61 mm (select 14.0 mm plate).