ChemProCal
Academy Knowledge Base + New Calculation Login Sign Up
ChemProCal • Fluid Mechanics • Dimensionless Numbers Calculator (Re, Pr, Sc, Sh, Nu, Le)
FLUID MECHANICS

Dimensionless Numbers Calculator (Re, Pr, Sc, Sh, Nu, Le)

Calculate momentum, heat, and mass transfer dimensionless groups including Reynolds (Re), Prandtl (Pr), Schmidt (Sc), Sherwood (Sh), Nusselt (Nu), Peclet (Pe), and Lewis (Le) numbers with Chilton-Colburn j-factors and boundary-layer analogies.

Verified Engineering Sizing Basis Standards: ASME / API / GPSA / ISA / TEMA

Calculate Reynolds (Re), Prandtl (Pr), Schmidt (Sc = nu/D), Sherwood (Sh = kc*L/D), Nusselt (Nu), and Lewis (Le) numbers with diffusivity ratios and worked examples.


⚡ Fluid Presets:

1. Geometry & Flow Conditions

2. Momentum & Thermal Fluid Properties

3. Mass Transfer Parameters (Schmidt & Sherwood)

×10⁻⁵ m²/s
Gases: ~1.0–2.5 ×10⁻⁵ | Liquids: ~0.0001–0.0003 ×10⁻⁵
Set to 0 to estimate kₒ automatically from Gilliland-Sherwood

Dimensionless Transport Numbers & Boundary-Layer Analysis

Fluid: Water - CO2 Absorption (20 C)
READY
Schmidt (Sc = ν/Dₐₑ)
--
Momentum vs. mass diffusion
Sherwood (Sh = kₒL/Dₐₑ)
--
Convective vs. diffusive mass
Reynolds (Re = ρvL/μ)
--
Inertia vs. viscous force
Prandtl (Pr = ν/α)
--
Momentum vs. thermal diffusion
Nusselt (Nu = hL/k)
--
Convective vs. conductive heat
Lewis (Le = Sc/Pr)
--
Thermal vs. mass diffusivity
RELATIVE BOUNDARY LAYER THICKNESS SCALING δᵥ / δᵀ ∝ Pr⁻¹⁄³ | δᵥ / δc ∝ Sc⁻¹⁄³
--
Solid Pipe Wall / Phase Interface (y = 0) δᵥ Momentum (1.00x) δᵀ Thermal δc Concentration

Molecular Diffusivities & Flux Scaling

Kinematic Viscosity (ν = μ/ρ)--
Thermal Diffusivity (α = k/ρCₚ)--
Mass Diffusivity (Dₐₑ)--
Convective Heat Coeff. (h)--
Mass Transfer Coeff. (kₒ predicted)--

Secondary & Chilton-Colburn Numbers

Thermal Péclet (Pe_h = Re · Pr)--
Mass Péclet (Pe_m = Re · Sc)--
Predicted Sherwood (Gilliland-Sherwood)--
Chilton-Colburn Heat Factor (j_H)--
Chilton-Colburn Mass Factor (j_D)--

Engineering Transport Diagnostics


📐 Engineering Formula & Specification Sheet

Dimensionless Numbers Calculator (Re, Pr, Sc, Sh, Nu, Le): Sizing Methodology & Engineering Basis

Calculate Reynolds (Re), Prandtl (Pr), Schmidt (Sc = nu/D), Sherwood (Sh = kc*L/D), Nusselt (Nu), and Lewis (Le) numbers with diffusivity ratios and worked examples.

📐 Author: Deepali Raut, M.Sc. Chemistry
🗓️ Standards: ASME / API / GPSA / ISA
⏱️ Format: Quick Reference Spec Sheet

Governing Transport Equations & Dimensionless Groups

In chemical engineering equipment design—from wetted-wall absorbers and packed scrubbers to shell-and-tube heat exchangers—dimensionless numbers collapse geometry, fluid properties, and flow velocity into universal scaling ratios between molecular diffusion and convective transport.

1. Schmidt Number ($Sc$) & Mass Diffusivity

The Schmidt number compares momentum diffusivity (kinematic viscosity $\nu$) to molecular mass diffusivity ($D_{AB}$):

$$ Sc = \frac{\nu}{D_{AB}} = \frac{\mu}{\rho \cdot D_{AB}} $$

In gas-phase mixtures (e.g., air–water vapor or methane), $Sc \approx 0.6\text{–}2.5$, meaning hydrodynamic and concentration boundary layers grow at similar rates ($\delta_v \approx \delta_c$). In liquid systems (e.g., $\text{CO}_2$ or salts in water), $Sc \approx 300\text{–}3,000+$, compressing mass transfer resistance into an ultra-thin film next to the phase interface.

2. Sherwood Number ($Sh$) & Convective Mass Transfer

The Sherwood number is the mass-transfer analog of the Nusselt number, comparing convective mass transport to pure molecular diffusion:

$$ Sh = \frac{k_c \cdot L}{D_{AB}} $$

For turbulent pipe and column flow ($Re > 4,000$), the Gilliland–Sherwood correlation estimates convective mass transfer directly from $Re$ and $Sc$: $Sh \approx 0.023\,Re^{0.83}\,Sc^{1/3}$.

3. Reynolds ($Re$), Prandtl ($Pr$), Nusselt ($Nu$), and Lewis ($Le$) Analogies

  • Reynolds Number ($Re = \rho v L / \mu$): Ratio of inertial forces to viscous forces; governs laminar ($ < 2,100$) vs. turbulent ($ > 4,000$) transition.
  • Prandtl Number ($Pr = C_p \mu / k$): Ratio of momentum diffusivity ($\nu$) to thermal diffusivity ($\alpha = k / \rho C_p$).
  • Nusselt Number ($Nu = h L / k$): Ratio of convective to conductive heat transfer at a solid boundary; evaluated via Dittus-Boelter ($Nu = 0.023\,Re^{0.8}\,Pr^n$) for turbulent duct flow.
  • Lewis Number ($Le = Sc / Pr = \alpha / D_{AB}$): Governs simultaneous heat and mass transfer (evaporative cooling, humidification); when $Le \approx 1$, thermal and concentration boundary layers coincide.
  • Chilton-Colburn Analogy ($j_H \approx j_D$): Links Stanton heat and mass transfer coefficients across $0.6 < Pr < 60$ and $0.6 < Sc < 3,000$: $j_H = St_h Pr^{2/3}$ and $j_D = St_m Sc^{2/3}$.

Worked Example: Aqueous CO₂ Absorption in a 100 mm Pipe

Water absorbs $\text{CO}_2$ at $20^\circ\text{C}$ flowing at $v = 1.50\text{ m/s}$ inside a $L = 0.10\text{ m}$ tube ($\rho = 998.2\text{ kg/m}^3$, $\mu = 1.002\text{ cP}$, $C_p = 4.182\text{ kJ/kg}\cdot\text{K}$, $k = 0.598\text{ W/m}\cdot\text{K}$, $D_{AB} = 1.90 \times 10^{-9}\text{ m}^2/\text{s}$, $k_c = 2.50 \times 10^{-4}\text{ m/s}$):

  1. Kinematic Viscosity: $\nu = 1.002 \times 10^{-3} / 998.2 = 1.004 \times 10^{-6}\text{ m}^2/\text{s}$.
  2. Reynolds Number: $Re = (998.2 \times 1.50 \times 0.10) / 0.001002 = 149,431$ (Fully Turbulent).
  3. Schmidt Number: $Sc = 1.004 \times 10^{-6} / (1.90 \times 10^{-9}) = 528.3$ (thin concentration boundary layer: $\delta_v / \delta_c \approx Sc^{1/3} = 8.08\times$).
  4. Sherwood Number: $Sh = (2.50 \times 10^{-4} \times 0.10) / (1.90 \times 10^{-9}) = 13,158$.
  5. Lewis Number: $Le = Sc / Pr = 528.3 / 7.01 = 75.4$ ($\alpha$ diffuses $75\times$ faster than dissolved $\text{CO}_2$).
📚 ChemProCal Knowledge Base

Need Complete Mathematical Derivations & Industrial Case Studies?

Explore our in-depth engineering textbook guide: Dimensionless Numbers in Chemical Engineering: Transport Phenomena Guide. Features step-by-step manual hand calculations, thermodynamic proofs, and commercial simulator benchmarks.

Methodology & Engineering Accuracy

This specification sheet and its mathematical formulations adhere to internationally recognized process codes (ASME, API, GPSA, TEMA, and ISA). Sizing parameters and default design allowances are cross-referenced with empirical industry design practices.

About This Tool

The Dimensionless Numbers & Transport Phenomena Calculator provides process and chemical engineers with a single unified workspace to compute momentum, thermal, and convective mass transfer scaling groups—including the Reynolds (Re), Prandtl (Pr), Schmidt (Sc), Sherwood (Sh), Nusselt (Nu), Peclet (Pe), and Lewis (Le) numbers alongside Chilton-Colburn $j_H$ and $j_D$ factors per standard transport phenomena literature (Bird, Stewart & Lightfoot; Perry's Chemical Engineers' Handbook; ASME & AIChE correlations).

1. Schmidt & Sherwood Numbers in Mass Transfer Design

The Schmidt number (Sc) and Sherwood number (Sh) form the backbone of absorber, stripper, membrane contactor, and wet scrubber sizing per Perry's Chemical Engineers' Handbook and AIChE mass-transfer design practice. Because liquid-phase diffusivities ($D_{AB} \sim 10^{-9}\text{ m}^2/\text{s}$) are roughly four orders of magnitude smaller than gas diffusivities ($\sim 10^{-5}\text{ m}^2/\text{s}$), liquid-film mass transfer exhibits high Schmidt numbers ($Sc > 300$), placing nearly all concentration resistance inside a thin boundary film.

2. Chilton-Colburn Analogy & Boundary-Layer Scaling

When experimental mass transfer coefficients $k_c$ are unavailable during conceptual process design, engineers use the Chilton-Colburn J-factor analogy ($j_D \approx j_H \approx f/2$) and Gilliland-Sherwood correlations to translate well-established heat transfer Nusselt ($Nu$) or Darcy friction ($f$) data directly into Sherwood numbers ($Sh$) for pipe flow, packed beds, and tubular reactors.

3. Engineering Standards & Application Boundaries

This calculator follows standard SI dimensional analysis per ASME PTC 19.1, TEMA heat transfer conventions, and Perry's 9th Edition transport tables. Dittus-Boelter ($Nu = 0.023\,Re^{0.8}\,Pr^n$) applies for fully turbulent flow ($Re > 10,000$, $0.6 \le Pr \le 160$, $L/D \ge 10$) with moderate wall-to-bulk temperature differences; highly viscous non-Newtonian slurries require Metzner-Reed generalized Reynolds corrections.

Frequently Asked Questions

What is the difference between the Schmidt number (Sc) and Prandtl number (Pr)?

The Prandtl number ($Pr = \nu / \alpha$) compares momentum diffusivity to thermal diffusivity for convective heat transfer, whereas the Schmidt number ($Sc = \nu / D_{AB}$) compares momentum diffusivity to molecular mass diffusivity for convective mass transfer. Their ratio gives the Lewis number ($Le = Sc / Pr = \alpha / D_{AB}$).

How do you calculate the Sherwood number (Sh) when k_c is unknown?

Set $k_c = 0$ in the calculator to evaluate $Sh$ automatically via the turbulent Gilliland-Sherwood pipe correlation ($Sh = 0.023\,Re^{0.83}\,Sc^{1/3}$) for $Re \ge 4,000$, or the fully developed laminar diffusive limit ($Sh = 3.66$) for $Re < 2,100$. The calculator then solves $k_c = Sh \cdot D_{AB} / L$.

Why is the Schmidt number around 1 for gases but 500 to 2,000 for liquids?

In gases, the same molecular collisions govern both momentum transfer (viscosity) and species diffusion, so $\nu$ and $D_{AB}$ are within a factor of ~0.6 to 2.5. In liquids, dense intermolecular forces resist molecular migration ($D_{AB} \sim 10^{-9}\text{ m}^2/\text{s}$) while transferring shear momentum efficiently, driving $Sc$ into the hundreds or thousands.

When does the Lewis number (Le = 1) assumption hold in process engineering?

For air-water vapor humidification and cooling towers near ambient conditions, $Le \approx 0.85\text{–}0.92 \approx 1.0$, justifying the Merkel enthalpy-driving-force approximation. For organic solvents or liquid-phase mass transfer ($Le \gg 1$), explicit Schmidt and Prandtl scaling ($j_H \approx j_D$) must be preserved.

Related Engineering Tools

Related Fundamentals

Tool Units

Input / Output Units

Configure global unit system preset or individual parameter dimensions.

CALCULATED RESULT
Ready