Governing Transport Equations & Dimensionless Groups
In chemical engineering equipment design—from wetted-wall absorbers and packed scrubbers to shell-and-tube heat exchangers—dimensionless numbers collapse geometry, fluid properties, and flow velocity into universal scaling ratios between molecular diffusion and convective transport.
1. Schmidt Number ($Sc$) & Mass Diffusivity
The Schmidt number compares momentum diffusivity (kinematic viscosity $\nu$) to molecular mass diffusivity ($D_{AB}$):
$$ Sc = \frac{\nu}{D_{AB}} = \frac{\mu}{\rho \cdot D_{AB}} $$
In gas-phase mixtures (e.g., air–water vapor or methane), $Sc \approx 0.6\text{–}2.5$, meaning hydrodynamic and concentration boundary layers grow at similar rates ($\delta_v \approx \delta_c$). In liquid systems (e.g., $\text{CO}_2$ or salts in water), $Sc \approx 300\text{–}3,000+$, compressing mass transfer resistance into an ultra-thin film next to the phase interface.
2. Sherwood Number ($Sh$) & Convective Mass Transfer
The Sherwood number is the mass-transfer analog of the Nusselt number, comparing convective mass transport to pure molecular diffusion:
$$ Sh = \frac{k_c \cdot L}{D_{AB}} $$
For turbulent pipe and column flow ($Re > 4,000$), the Gilliland–Sherwood correlation estimates convective mass transfer directly from $Re$ and $Sc$: $Sh \approx 0.023\,Re^{0.83}\,Sc^{1/3}$.
3. Reynolds ($Re$), Prandtl ($Pr$), Nusselt ($Nu$), and Lewis ($Le$) Analogies
- Reynolds Number ($Re = \rho v L / \mu$): Ratio of inertial forces to viscous forces; governs laminar ($ < 2,100$) vs. turbulent ($ > 4,000$) transition.
- Prandtl Number ($Pr = C_p \mu / k$): Ratio of momentum diffusivity ($\nu$) to thermal diffusivity ($\alpha = k / \rho C_p$).
- Nusselt Number ($Nu = h L / k$): Ratio of convective to conductive heat transfer at a solid boundary; evaluated via Dittus-Boelter ($Nu = 0.023\,Re^{0.8}\,Pr^n$) for turbulent duct flow.
- Lewis Number ($Le = Sc / Pr = \alpha / D_{AB}$): Governs simultaneous heat and mass transfer (evaporative cooling, humidification); when $Le \approx 1$, thermal and concentration boundary layers coincide.
- Chilton-Colburn Analogy ($j_H \approx j_D$): Links Stanton heat and mass transfer coefficients across $0.6 < Pr < 60$ and $0.6 < Sc < 3,000$: $j_H = St_h Pr^{2/3}$ and $j_D = St_m Sc^{2/3}$.
Worked Example: Aqueous CO₂ Absorption in a 100 mm Pipe
Water absorbs $\text{CO}_2$ at $20^\circ\text{C}$ flowing at $v = 1.50\text{ m/s}$ inside a $L = 0.10\text{ m}$ tube ($\rho = 998.2\text{ kg/m}^3$, $\mu = 1.002\text{ cP}$, $C_p = 4.182\text{ kJ/kg}\cdot\text{K}$, $k = 0.598\text{ W/m}\cdot\text{K}$, $D_{AB} = 1.90 \times 10^{-9}\text{ m}^2/\text{s}$, $k_c = 2.50 \times 10^{-4}\text{ m/s}$):
- Kinematic Viscosity: $\nu = 1.002 \times 10^{-3} / 998.2 = 1.004 \times 10^{-6}\text{ m}^2/\text{s}$.
- Reynolds Number: $Re = (998.2 \times 1.50 \times 0.10) / 0.001002 = 149,431$ (Fully Turbulent).
- Schmidt Number: $Sc = 1.004 \times 10^{-6} / (1.90 \times 10^{-9}) = 528.3$ (thin concentration boundary layer: $\delta_v / \delta_c \approx Sc^{1/3} = 8.08\times$).
- Sherwood Number: $Sh = (2.50 \times 10^{-4} \times 0.10) / (1.90 \times 10^{-9}) = 13,158$.
- Lewis Number: $Le = Sc / Pr = 528.3 / 7.01 = 75.4$ ($\alpha$ diffuses $75\times$ faster than dissolved $\text{CO}_2$).