🛡️ HAZOP RISK STUDY TAG: C-201 📜 IEC 61882 / OSHA 1910.119 PSM

Amine Absorber HAZOP Deviation Study (C-201)

Interactive Industrial Simulation • Standards Verification • Reward: +150 XP

Reward
+150 XP
📐

Interactive Process & Instrumentation Schematic

ISA-5.1 Vector Standard
C-201 65 barg MDEA Lean Amine In (FCV-201) Sour Gas In (50 MMSCFD) Treated Sales Gas Rich Amine to Flash Tank !
💡 Inspect nozzle configurations, flow directions, instruments, and discrepancy flags marked with !

1. Industrial Operating Briefing

Context & Boundaries

Lead the HAZOP study on Node 3: Lean amine inlet stream to Column C-201 (High-Pressure Acid Gas Absorber). Sour feed gas contains 3.5 mol% H2S and 5.0 mol% CO2 at 65 barg. Evaluate deviations: MORE H2S, LESS Lean Amine Flow, and REVERSE Flow across the high-pressure check valve.

2. Equipment Process Datasheet

Specifications Under Review
Sour Gas Flow 50 MMSCFD (3.5 mol% H2S, 5.0 mol% CO2)
Sales Gas Spec < 4 ppmv H2S, < 2 mol% CO2
Contactor Pressure 65 barg
Lean Amine Solvent 45 wt% Formulated MDEA
⚡ Verify in ChemProCal Live Tool

Open the dedicated engineering calculator to independently verify velocities, duties, and hydraulic limits.

Open Amine Gas Sweetening & Acid Gas Removal Unit Sizer ↗

3. HAZOP Safeguard & Risk Checklist

Simulation Active

Review the node deviations. Check each confirmed cause, potential consequence, and required engineering safeguard: