← Back to Career Pathways
🧮 Open Practice Drills
EPC Engineering Practice
Experience: 2 - 6 Years
EPC Process Design Engineer (FEED & Detailed Engineering)
Tailored for process engineers delivering Front-End Engineering Design (FEED) and Detailed Engineering packages in EPC organizations. Covers hydraulic calculations, equipment datasheets, P&ID development, and design standards.
Milestone Module 1
1. P&ID Development, Control Philosophy & Interlocks
Develop piping and instrumentation diagrams, fail-safe logic, bypass configurations, and shutdown trips.
⚡ Rapid-Fire Interview Questions & Model Answers (8)
Click to toggle answer
Q1: How do you do control valve sizing? Explain the step-by-step methodology, flow coefficients, and cavitation checks.
Q2: If a line has a control valve and assume it has different flow rates (100 kg/hr, 150 kg/hr, and 200 kg/hr), in which flow rate is the valve $\Delta P$ higher? Explain why.
Q3: How do you do BDV sizing? Explain the API 521 15-minute depressuring criterion, restriction orifice sizing, and low-temperature MDMT risk.
Q4: What are the design challenges in choke valves, and how do multi-stage trims prevent cavitation, flashing, and acoustic fatigue?
Q5: Explain the isolation philosophy in P&ID development. When is Double Block & Bleed (DBB) mandated over Single Block & Bleed (SBB)?
Q6: What is PSD? Explain the different hierarchical levels of process shutdown (Level 0, 1, 2, and 3) in plant safety design.
Q7: How can an EPC engineer justify a piping specification break from 600# to 300# without installing a downstream PSV?
Q8: How do you determine the fail-safe action (Fail Open, Fail Closed, or Fail Locked) for control valves during P&ID development?
Milestone Module 2
2. Equipment Datasheets & Mechanical Integration
Audit process datasheets for heat exchangers, pumps, compressors, and pressure vessels against ASME and API standards.
⚡ Rapid-Fire Interview Questions & Model Answers (6)
Click to toggle answer
Q1: What are the various types of atmospheric and low-pressure storage tanks? How do you match tank geometry to fluid volatility?
Q2: What is the exact engineering difference between an API 650 tank and an API 620 tank?
Q3: What are the credible overpressure and vacuum scenarios for atmospheric storage tanks per API 2000? How are PVRVs sized?
Q4: What parameters are documented in a process Line List? What do the ALT 1, ALT 2, ALT 3, and ALT 4 columns represent?
Q5: What is a Process General Arrangement (GA) drawing? How does it differ from a PFD and P&ID in engineering workflow?
Q6: What is the technical and historical difference between Aspen HYSYS and Honeywell UniSim Design? What are their latest applications?
Academy Sections
Jump directly to any engineering module